CompTIA Security+ SY0-701 Flashcards: 369 cards
369 free CompTIA Security+ flashcards from the course's cheat sheet and glossary. Tap a card to flip it. Mark the ones you know and they drop out of the deck; the rest keep coming back.
Space flips, arrow keys move. Known cards are remembered in this browser.
Acronyms 206
- 3DES
- Triple Data Encryption Standard. DES applied three times; legacy and slow, replaced by AES.
- 802.1X
- IEEE 802.1X. Port-based network access control: a device must authenticate before the switch port or Wi-Fi passes traffic.
- AAA
- Authentication, authorization, and accounting. Prove who you are, decide what you may do, record what you did.
- ABAC
- Attribute-based access control. Access decisions based on attributes of the user, resource, and context, such as time and location.
- ACL
- Access control list. An ordered list of permit and deny rules on a router, firewall, or file system.
- AES
- Advanced Encryption Standard. The standard symmetric cipher, with 128, 192, or 256-bit keys.
- AES-128
- AES with a 128-bit key. The standard-strength AES, secure and fast.
- AES-256
- AES with a 256-bit key. The high-strength AES used for data at rest and sensitive sessions.
- AES-CCMP
- AES in CCMP mode. The AES-based encryption WPA2 uses for Wi-Fi.
- AH
- Authentication Header. The IPsec protocol that provides integrity and authentication without encryption.
- ALE
- Annualized loss expectancy. The expected yearly cost of a risk: SLE times ARO.
- AP
- Access point. The radio that bridges Wi-Fi clients onto the wired network.
- API
- Application programming interface. The defined way one program talks to another, such as the web endpoints a cloud service exposes.
- APT
- Advanced persistent threat. A well-funded, skilled, patient attacker, usually a nation-state, that stays hidden for a long time.
- ARO
- Annualized rate of occurrence. How many times per year an incident is expected to happen.
- ARP
- Address Resolution Protocol. Finds the MAC address that goes with a known IPv4 address on the local segment.
- ASLR
- Address space layout randomization. Randomizes where programs load in memory so exploits cannot predict addresses.
- AUP
- Acceptable use policy. The rules for how staff may use company systems and data.
- AV
- Asset value. What an asset is worth, the first number in quantitative risk analysis (SLE = AV x EF). Also: Antivirus. Software that detects, quarantines, and removes malware using signatures, heuristics, and behavior.
- BEC
- Business email compromise. Fraud by email impersonating an executive or vendor to redirect payments.
- BIA
- Business impact analysis. Identifies critical functions and what an outage of each would cost, setting RTO and RPO.
- BPA
- Business partnership agreement. How partners share responsibilities, profits, and liabilities.
- BYOD
- Bring your own device. Staff use personal phones and laptops for work.
- CA
- Certificate authority. The trusted entity that signs certificates.
- CEO
- Chief executive officer. The top executive; the person impersonated in whaling and business email compromise.
- CFO
- Chief financial officer. The executive in charge of money; a common target and impersonation in payment fraud.
- CI
- Continuous integration. Every code change is automatically built and tested when it is committed.
- CIA
- Confidentiality, integrity, and availability. The three goals of security: keep data secret, keep it correct, keep it reachable.
- CIS
- Center for Internet Security. The organization that publishes hardening benchmarks and the CIS Controls.
- COPE
- Corporate-owned, personally enabled. The company buys the device and lets staff use it personally.
- CPU
- Central processing unit. The processor that executes instructions.
- CRL
- Certificate revocation list. A signed list of revoked certificate serial numbers published by a CA.
- CSR
- Certificate signing request. The file containing a public key and identity that you send to a CA to get a certificate.
- CSRF
- Cross-site request forgery. Tricks a logged-in user's browser into sending a request the user did not intend.
- CVE
- Common Vulnerabilities and Exposures. The public identifier for a known vulnerability, such as CVE-2024-12345.
- CVSS
- Common Vulnerability Scoring System. A 0 to 10 severity score for a vulnerability.
- CYOD
- Choose your own device. Staff pick from a list of approved devices the company then owns and manages.
- DAC
- Discretionary access control. The owner of a resource decides who may access it.
- DBA
- Database administrator. The person who runs the database servers.
- DDoS
- Distributed denial of service. Many sources, usually a botnet, flood a target at once.
- DER
- Distinguished Encoding Rules. The binary format for certificates and keys.
- DES
- Data Encryption Standard. The 1970s 56-bit block cipher; broken by brute force, do not use.
- DHCP
- Dynamic Host Configuration Protocol. Hands out IP addresses, masks, gateways, and DNS servers automatically (UDP 67 and 68).
- DKIM
- DomainKeys Identified Mail. Outgoing mail is digitally signed; the public key is published in DNS.
- DLP
- Data loss prevention. Tools that detect and block sensitive data leaving by email, web, USB, or cloud.
- DMARC
- Domain-based Message Authentication, Reporting, and Conformance. A DNS policy telling receivers what to do with mail that fails SPF or DKIM, and where to send reports.
- DMZ
- Demilitarized zone. A screened subnet between the internet and the internal network for public-facing servers.
- DNS
- Domain Name System. Translates names such as www.example.com into IP addresses (UDP 53, TCP 53 for zone transfers).
- DNSSEC
- DNS Security Extensions. Digital signatures on DNS records so a resolver can tell an answer was not forged.
- DoH
- DNS over HTTPS. DNS queries carried inside HTTPS on TCP 443 so they cannot be read or altered in transit.
- DoS
- Denial of service. One source floods or crashes a target so it cannot serve users.
- DoT
- DNS over TLS. DNS queries encrypted with TLS on TCP 853.
- DSA
- Digital Signature Algorithm. A government-standard signature algorithm; used less than RSA and ECDSA today.
- EAP
- Extensible Authentication Protocol. The framework that carries authentication methods inside 802.1X.
- EAP-FAST
- EAP Flexible Authentication via Secure Tunneling. Cisco's tunneled EAP method using a protected access credential instead of a certificate.
- EAP-TLS
- EAP with Transport Layer Security. Certificate-based authentication on both sides; the strongest Wi-Fi and wired 802.1X method.
- EAP-TTLS
- EAP with Tunneled TLS. A server certificate builds a TLS tunnel, then the client authenticates inside it with a password or other method.
- ECC
- Elliptic curve cryptography. Public-key cryptography that gives RSA-level strength with much shorter keys, ideal for phones and IoT.
- ECDHE
- Elliptic Curve Diffie-Hellman Ephemeral. Key exchange with a fresh elliptic curve key per session, giving forward secrecy.
- ECDSA
- Elliptic Curve Digital Signature Algorithm. Digital signatures using elliptic curve keys.
- EDR
- Endpoint detection and response. Endpoint agents that record activity, detect attacks, and let responders isolate and clean the machine.
- EF
- Exposure factor. The fraction of an asset's value lost in one incident.
- ESP
- Encapsulating Security Payload. The IPsec protocol that encrypts and authenticates the payload.
- FIDO2
- Fast Identity Online 2. Passwordless or second-factor authentication with a hardware security key or device biometrics.
- FIM
- File integrity monitoring. Alerts when critical files or configurations change.
- FTP
- File Transfer Protocol. Plaintext file transfer on TCP 21 (control) and 20 (data); replace with SFTP or FTPS.
- FTPS
- FTP Secure. FTP wrapped in TLS, ports 990 and 989 (implicit) or 21 with an upgrade (explicit).
- GB
- Gigabyte. About a billion bytes; the unit for RAM, storage, and data caps.
- GCMP
- Galois/Counter Mode Protocol. The stronger AES encryption mode used by WPA3.
- GPS
- Global Positioning System. Satellite positioning, also used as a stratum 0 time reference.
- HMAC
- Hash-based message authentication code. A keyed hash that proves a message came from someone with the key and was not altered.
- HR
- Human resources. The department that hires and separates staff; its system should drive account provisioning and removal.
- HSM
- Hardware security module. A tamper-resistant appliance or card that generates, stores, and uses cryptographic keys.
- HTTP
- Hypertext Transfer Protocol. Web traffic in the clear on TCP 80.
- HTTPS
- Hypertext Transfer Protocol Secure. HTTP inside TLS on TCP 443.
- IaaS
- Infrastructure as a service. The provider supplies virtual machines, storage, and networks; you manage the operating system and up.
- IaC
- Infrastructure as code. Defining networks and servers in files that tools build automatically and repeatably.
- ICS
- Industrial control system. The general term for computers that run physical processes; SCADA is one kind.
- ID
- Identifier or identification. A name or number that uniquely labels a user, device, session, or record.
- IDS
- Intrusion detection system. Watches a copy of the traffic and alerts on attacks; cannot block them.
- IKE
- Internet Key Exchange. Negotiates the keys and security associations for IPsec; UDP 500, and 4500 through NAT.
- IMAP
- Internet Message Access Protocol. Reads mail that stays on the server, synced across devices; TCP 143, secure 993.
- IMAPS
- IMAP Secure. IMAP over TLS on TCP 993.
- iOS
- iPhone operating system. Apple's mobile operating system for iPhone.
- IoT
- Internet of Things. Networked devices such as cameras, sensors, thermostats, and smart TVs.
- IP
- Internet Protocol. The Layer 3 protocol that addresses and routes packets between networks.
- IPS
- Intrusion prevention system. Sits inline and blocks attacks as they pass.
- IPsec
- Internet Protocol Security. The suite that encrypts and authenticates IP packets for VPNs.
- ISAC
- Information sharing and analysis center. An industry group where members share threat intelligence.
- IT
- Information technology. Computers, networks, and the people who run them.
- KMS
- Key management service. A managed, usually cloud-hosted, service that creates, stores, rotates, and controls access to encryption keys.
- LACP
- Link Aggregation Control Protocol. Negotiates bundling several physical links into one logical link (802.1AX, formerly 802.3ad).
- LAN
- Local area network. One site's network: a building, floor, or campus that one organization owns and runs.
- LDAP
- Lightweight Directory Access Protocol. Queries a directory such as Active Directory for users and groups; TCP 389, secure 636.
- LDAPS
- LDAP Secure. LDAP over TLS on TCP 636.
- LTE
- Long-Term Evolution. 4G cellular data; the workhorse mobile broadband standard.
- MAC
- Media access control (address). The 48-bit Layer 2 hardware address of a network interface, which a switch uses to forward frames. Also: Mandatory access control. The access control model where the system assigns classification labels that users cannot change.
- MD5
- Message Digest 5. A 128-bit hash that is broken: collisions can be manufactured; recognize, never recommend.
- MDM
- Mobile device management. Software that enrolls phones and tablets and enforces policy: passcodes, encryption, apps, remote wipe.
- MFA
- Multi-factor authentication. Two or more different kinds of proof: something you know, have, are, or where you are.
- MIME
- Multipurpose Internet Mail Extensions. The standard that lets email carry attachments and non-text content.
- MOA
- Memorandum of agreement. A more formal, sometimes binding, statement of what parties agree to do.
- MOU
- Memorandum of understanding. A non-binding statement of intent and roles between parties.
- MPLS
- Multiprotocol Label Switching. A provider WAN that forwards by short labels instead of IP lookups, with traffic engineering and QoS.
- ms
- Millisecond. One thousandth of a second; latency and response times.
- MSA
- Master service agreement. The umbrella contract covering a whole vendor relationship; individual jobs hang off it.
- MTBF
- Mean time between failures. The average running time before a component fails; a reliability measure.
- MTTR
- Mean time to repair. The average time to fix a failure and restore service.
- NAC
- Network access control. Checks a device's identity and health before letting it onto the network.
- NAT-T
- NAT traversal. Wraps IPsec in UDP 4500 so it can pass through address translation.
- NDA
- Non-disclosure agreement. A contract that keeps shared information confidential.
- NGFW
- Next-generation firewall. A firewall that identifies applications and users, and includes intrusion prevention.
- NTP
- Network Time Protocol. Synchronizes clocks across the network (UDP 123); wrong time breaks Kerberos, certificates, and logs.
- NTS
- Network Time Security. Authentication and integrity for NTP so time cannot be spoofed.
- OAuth
- Open Authorization. Lets a user grant an application limited access to their account on another service without sharing the password.
- OCSP
- Online Certificate Status Protocol. A real-time query to the CA asking whether one certificate is revoked.
- OS
- Operating system. The software that manages hardware and runs applications: Windows, macOS, Linux, iOS, Android.
- OSINT
- Open-source intelligence. Information gathered from public sources: websites, social media, records, DNS.
- P7B
- PKCS #7 bundle. A file holding a certificate chain with no private key.
- PBKDF2
- Password-Based Key Derivation Function 2. Stretches a password with many hash rounds so guessing is slow.
- PEAP
- Protected EAP. A server certificate creates a TLS tunnel and the user's password is checked inside it.
- PEM
- Privacy Enhanced Mail (format). The Base64 text format for certificates and keys, with BEGIN and END lines.
- PFX
- Personal Information Exchange. A password-protected bundle holding a certificate and its private key (also .p12).
- PIN
- Personal identification number. A short numeric secret, a something-you-know factor.
- PKI
- Public key infrastructure. The system of certificate authorities, certificates, and revocation that makes public keys trustworthy.
- POP3
- Post Office Protocol version 3. Downloads mail to one device and usually deletes it from the server; TCP 110, secure 995.
- POP3S
- POP3 Secure. POP3 over TLS on TCP 995.
- PSK
- Pre-shared key. One shared passphrase for everyone on a Wi-Fi network (Personal mode).
- RA
- Registration authority. The part of a PKI that verifies identities before the CA signs.
- RADIUS
- Remote Authentication Dial-In User Service. The AAA server behind Wi-Fi Enterprise, VPNs, and 802.1X; UDP 1812 and 1813.
- RAID
- Redundant array of independent disks. Combining disks for speed, capacity, or fault tolerance: 0 stripe, 1 mirror, 5 stripe with parity, 6 double parity, 10 mirrored stripes.
- RAM
- Random-access memory. The working memory that holds running programs and data; lost at power off.
- RAT
- Remote access trojan. Malware that opens a back door so an attacker can control the machine.
- RBAC
- Role-based access control. Permissions are assigned to roles, and users get roles.
- RC4
- Rivest Cipher 4. A fast stream cipher used in WEP and old TLS; broken and deprecated.
- RDP
- Remote Desktop Protocol. Microsoft's remote graphical desktop on TCP 3389.
- RFID
- Radio-frequency identification. Tags read by radio for badges, inventory, and asset tracking.
- RPO
- Recovery point objective. The maximum acceptable data loss, measured in time.
- RSA
- Rivest, Shamir, Adleman. The classic public-key algorithm for encryption and digital signatures.
- RTO
- Recovery time objective. The maximum acceptable time to restore a service after failure.
- RTOS
- Real-time operating system. An operating system that guarantees responses within strict time limits, used in embedded and control devices.
- RTP
- Real-time Transport Protocol. Carries the actual voice and video packets of a call, over UDP.
- SaaS
- Software as a service. Complete applications delivered over the web, such as email and office suites.
- SAE
- Simultaneous authentication of equals. The WPA3 Personal handshake that resists offline password guessing.
- SAML
- Security Assertion Markup Language. An XML standard for passing authentication between an identity provider and a web application (enterprise SSO).
- SAN
- Subject alternative name. The certificate field listing every hostname the certificate is valid for.
- SASE
- Secure access service edge. SD-WAN networking plus cloud-delivered security (firewall, web gateway, ZTNA, CASB) as one service.
- SCADA
- Supervisory control and data acquisition. Systems that monitor and control industrial processes such as power, water, and manufacturing.
- SCAP
- Security Content Automation Protocol. Standard formats that let tools check systems against security benchmarks automatically.
- SD-WAN
- Software-defined wide area network. Steers traffic across several cheap links (broadband, LTE, MPLS) by policy from a central controller.
- SDLC
- Software development life cycle. The phases of building software: plan, design, code, test, deploy, maintain.
- SDN
- Software-defined networking. Separates the control plane (decisions) from the data plane (forwarding) and centralizes control.
- SFTP
- SSH File Transfer Protocol. File transfer inside an SSH session, TCP 22.
- SHA
- Secure Hash Algorithm. The family of hash functions: SHA-1 (deprecated), SHA-2 (SHA-256, the standard), SHA-3.
- SHA-1
- Secure Hash Algorithm 1. A 160-bit hash, deprecated because collisions have been found.
- SHA-2
- Secure Hash Algorithm 2. The current hash family, including SHA-256 and SHA-512.
- SHA-256
- Secure Hash Algorithm 256-bit. The standard hash today: a 256-bit fingerprint of any input.
- SHA-3
- Secure Hash Algorithm 3. A newer hash standard with a different internal design from SHA-2.
- SIEM
- Security information and event management. Collects logs from everything, correlates them, and raises alerts.
- SIP
- Session Initiation Protocol. Sets up and tears down voice and video calls; port 5060, or 5061 with TLS.
- SLA
- Service level agreement. The contract stating measurable service commitments, such as 99.9% uptime.
- SLE
- Single loss expectancy. The cost of one occurrence of a risk: asset value times exposure factor.
- SMB
- Server Message Block. Windows file and printer sharing on TCP 445.
- SMS
- Short Message Service. Text messages; used for one-time codes and also a phishing channel (smishing).
- SMTP
- Simple Mail Transfer Protocol. Sends email between servers on TCP 25; clients submit on 587 with TLS.
- SMTPS
- SMTP Secure. SMTP with TLS, port 465 (implicit) or 587 with STARTTLS.
- SNMP
- Simple Network Management Protocol. Polls and receives alerts from network devices (UDP 161 polls, 162 traps).
- SOW
- Statement of work. Defines one specific piece of work: deliverables, timeline, and price.
- SPF
- Sender Policy Framework. A DNS TXT record listing which servers may send mail for a domain.
- SQL
- Structured Query Language. The language used to query databases; also the name of the servers on TCP 1433 (Microsoft) and 3306 (MySQL).
- SRTP
- Secure Real-time Transport Protocol. Encrypted RTP for voice and video.
- SSH
- Secure Shell. Encrypted remote command-line access and file transfer on TCP 22; replaces Telnet and FTP.
- SSID
- Service set identifier. The Wi-Fi network name that access points broadcast and clients join.
- SSL
- Secure Sockets Layer. The predecessor of TLS; every version is deprecated.
- SSO
- Single sign-on. Log in once and reach many systems without signing in again.
- SSRF
- Server-side request forgery. Makes the web server itself fetch a URL the attacker supplies, often reaching internal systems.
- SY0-701
- CompTIA Security+ exam SY0-701. The current version of the Security+ certification exam.
- TACACS+
- Terminal Access Controller Access-Control System Plus. Cisco's AAA protocol for device administration on TCP 49; encrypts the whole payload and separates authentication from authorization.
- TCP
- Transmission Control Protocol. Reliable, ordered, connection-based transport: three-way handshake, acknowledgments, retransmission.
- TFTP
- Trivial File Transfer Protocol. Bare-bones UDP 69 file transfer with no login, used for firmware and config files.
- TKIP
- Temporal Key Integrity Protocol. WPA's per-packet keying scheme; deprecated.
- TLS
- Transport Layer Security. The encryption layer under HTTPS and most secure protocols; use 1.2 or 1.3.
- TOC
- Time of check. The moment a program verifies a condition; in a race condition, before it acts on it.
- TOU
- Time of use. The moment a program acts on a condition it checked earlier.
- TPM
- Trusted Platform Module. A security chip on the motherboard that stores keys and measurements; required for BitLocker and Windows 11.
- TV
- Television. A display or broadcast receiver; smart TVs are IoT devices.
- UBA
- User behavior analytics. Baselines what each user normally does and flags deviations.
- UEFI
- Unified Extensible Firmware Interface. Modern firmware that replaces BIOS: GPT disks, Secure Boot, mouse-driven setup.
- UPS
- Uninterruptible power supply. A battery unit that keeps equipment running through a power cut and conditions the power.
- URL
- Uniform resource locator. A web address such as https://www.example.com/page.
- USB
- Universal Serial Bus. The standard port for peripherals, storage, and charging.
- UTM
- Unified threat management. One appliance bundling firewall, IDS/IPS, antivirus, content filtering, and VPN.
- VLAN
- Virtual local area network. A logical LAN on a switch: ports in different VLANs are separate broadcast domains.
- VM
- Virtual machine. A complete computer running as software on a hypervisor.
- VPN
- Virtual private network. An encrypted tunnel across an untrusted network such as the internet.
- WAF
- Web application firewall. A firewall that understands HTTP and blocks attacks on web applications such as SQL injection and XSS.
- WAN
- Wide area network. Connects LANs across cities or countries, usually over links leased from a provider.
- WEP
- Wired Equivalent Privacy. The original Wi-Fi encryption, broken in minutes; never use it.
- Wi-Fi
- Wireless fidelity. The trade name for IEEE 802.11 wireless networking.
- WO
- Work order. A short authorization for one specific job.
- WPA
- Wi-Fi Protected Access. The interim fix for WEP that used TKIP; deprecated.
- WPA2
- Wi-Fi Protected Access 2. Wi-Fi security using AES with CCMP; still common and acceptable.
- WPA3
- Wi-Fi Protected Access 3. The current Wi-Fi security standard: SAE in Personal mode, stronger encryption, protected management frames.
- XDR
- Extended detection and response. EDR extended across endpoints, network, cloud, and email into one correlated view.
- XML
- Extensible Markup Language. A text format for structured data, used by SAML, SOAP, and many configuration files.
- XSS
- Cross-site scripting. An attacker's script runs in other users' browsers because a site echoes untrusted input.
The exam itself 9
- Exam code
- SY0-701 (Security+)
- Questions
- Up to 90, multiple choice plus performance-based
- Time
- 90 minutes
- Passing score
- 750 on a scale of 100 to 900 (about 83%)
- 1.0 General Security Concepts
- 12%
- 2.0 Threats, Vulnerabilities, and Mitigations
- 22%
- 3.0 Security Architecture
- 18%
- 4.0 Security Operations
- 28%
- 5.0 Security Program Management and Oversight
- 20%
Cryptography 25
- Symmetric
- One shared key encrypts and decrypts. Fast, bulk data. AES (128, 192, 256-bit), 3DES (legacy), ChaCha20, Blowfish
- Asymmetric
- Public key encrypts or verifies, private key decrypts or signs. Slow, used for key exchange and signatures. RSA, ECC (smaller keys, same strength), DSA, ECDSA
- Key exchange
- Diffie-Hellman and ECDHE agree on a shared key over an open channel. Ephemeral keys give perfect forward secrecy
- Hashing
- One-way fixed-length fingerprint: MD5 128-bit (broken), SHA-1 160-bit (deprecated), SHA-256, SHA-3. HMAC adds a key for authenticity
- Salting
- Random data added to a password before hashing so identical passwords hash differently and rainbow tables fail
- Key stretching
- Make hashing slow on purpose: PBKDF2, bcrypt, scrypt, Argon2
- Digital signature
- Hash the message, encrypt the hash with the private key. Proves integrity, authenticity, and non-repudiation
- Key length
- Longer is stronger; AES-256 over AES-128, RSA 2048 minimum, ECC 256 is comparable to RSA 3072
- Blockchain
- Open public ledger: chained hashed blocks, tamper-evident, distributed
- Transport encryption
- TLS 1.2 and 1.3 for web and mail, IPsec for VPNs, SSH for shells. Deprecated: SSL, TLS 1.0 and 1.1
- Full-disk
- The whole drive; protects a lost laptop
- Partition or volume
- One partition or logical volume
- File
- Individual files
- Database
- The whole database
- Record
- Individual fields or rows, such as card numbers
- Certificate authority (CA)
- Issues and signs certificates; the root of trust
- Registration authority
- Verifies identity before the CA issues
- CSR
- Certificate signing request: the public key plus identity sent to the CA
- CRL
- Certificate revocation list, downloaded periodically; can be stale
- OCSP
- Real-time revocation check of one certificate; OCSP stapling has the server include a fresh response
- Self-signed
- Not signed by a trusted CA; browsers warn; internal use only
- Third-party
- Issued by a public CA; trusted by browsers
- Wildcard
- *.example.com covers every subdomain at one level
- SAN
- Subject alternative name: several names on one certificate
- Formats
- PEM (Base64 text, .crt .pem), DER (binary), PFX or P12 (with private key), P7B (chain, no private key)
Threat actors, vectors, and social engineering 19
- Message-based
- Email, SMS, instant messaging
- Image-based and file-based
- Malicious images, macros in documents, executables
- Voice call
- Vishing
- Removable device
- USB drops
- Vulnerable software
- Client-based (agent installed) versus agentless
- Unsupported systems
- End-of-life operating systems and applications
- Unsecure networks
- Open wireless, unmanaged wired ports, Bluetooth
- Open service ports, default credentials
- Exposed services, unchanged admin passwords
- Supply chain
- Managed service providers, vendors, suppliers
- Phishing
- Fraudulent email to steal credentials or deliver malware
- Vishing, smishing
- The same by voice call, by text message
- Spear phishing, whaling
- Targeted at a person; targeted at an executive
- Business email compromise
- Attacker uses or imitates a real business account to redirect payments
- Pretexting
- An invented story that justifies the request
- Impersonation, brand impersonation
- Pretending to be a person; pretending to be a company
- Watering hole
- Compromise a site the targets already visit
- Typosquatting
- Look-alike domain names catching mistyped URLs
- Misinformation, disinformation
- False content spread unknowingly; spread deliberately
- Tailgating, shoulder surfing, dumpster diving
- Following through a door; watching a screen; reading the trash
Vulnerabilities 11
- Application
- Memory injection, buffer overflow, race conditions (time-of-check to time-of-use), malicious update
- Operating system
- Unpatched services, weak defaults
- Web-based
- SQL injection (' OR 1=1), cross-site scripting (script in a page other users load)
- Hardware
- Firmware flaws, end-of-life, legacy devices
- Virtualization
- VM escape (guest reaches the host), resource reuse (data left in reallocated memory or storage)
- Cloud-specific
- Misconfigured storage, shared-tenant risks, exposed APIs
- Supply chain
- Service provider, hardware provider, software provider
- Cryptographic
- Weak or deprecated algorithms, short keys, bad implementations
- Misconfiguration
- Open ports, default settings, excessive permissions
- Mobile
- Side loading (apps from outside the store), jailbreaking or rooting
- Zero-day
- Known to attackers before a patch exists
Attacks and indicators 8
- Ransomware
- Files encrypted, payment demanded
- Trojan
- Hidden inside a wanted program; remote access trojan gives control
- Worm
- Spreads by itself across the network
- Virus
- Attaches to files, needs a user action to spread
- Spyware, keylogger
- Watches activity; records keystrokes
- Bloatware
- Unwanted preinstalled software, expands attack surface
- Logic bomb
- Triggers on a date or event
- Rootkit
- Hides at kernel or firmware level; survives reboots, evades antivirus
Security architecture 12
- Security zones
- Trusted, untrusted, screened subnet (DMZ) for public-facing servers
- Attack surface
- Everything reachable; shrink it
- Fail-open versus fail-closed
- Fail-open keeps traffic flowing when the control fails (availability); fail-closed blocks (security)
- Active versus passive
- Inline (can block, can bottleneck) versus tap or monitor port (sees a copy, alerts only)
- Jump server
- Hardened host you go through to reach protected systems
- Proxy server
- Forward proxy for clients; reverse proxy in front of servers
- IPS versus IDS
- Inline and blocks versus out of band and alerts
- Load balancer
- Spreads traffic; active-active or active-passive
- Sensors
- Collect traffic or logs for monitoring
- Port security
- 802.1X authentication on switch ports and Wi-Fi, using EAP (EAP-TLS with certificates is strongest; PEAP, EAP-TTLS, EAP-FAST)
- Firewall types
- WAF (Layer 7, protects web apps), UTM (all-in-one), NGFW (application-aware, user-aware), Layer 4 (ports) versus Layer 7 (content)
- Secure communication
- VPN and remote access; tunneling with TLS or IPsec; SD-WAN; SASE (network plus cloud security)
Data protection 9
- Regulated
- Law or regulation governs it: health, payment card, personal data
- Trade secret, intellectual property
- Formulas, source code, designs
- Legal information, financial information
- Contracts, litigation; ledgers, filings
- Human-readable versus non-human-readable
- Documents versus binaries and encrypted blobs
- Public
- Anyone may see it
- Private, sensitive
- Internal; harm if leaked
- Confidential
- Limited to those who need it
- Restricted
- Tightly controlled, often regulated
- Critical
- The organization cannot function without it
Resilience and recovery 12
- Load balancing versus clustering
- Spreads requests across servers; servers act as one system with failover
- Hot site
- Running mirror, minutes to switch, most expensive
- Warm site
- Equipment ready, data restored on failover, hours
- Cold site
- Space and power only, days
- Geographic dispersion
- Sites far enough apart that one disaster cannot hit both
- Platform diversity, multi-cloud
- Different vendors so one flaw or outage does not take everything
- Continuity of operations
- Keep the business running through the incident
- Capacity planning
- People, technology, infrastructure sized for growth and surge
- Testing
- Tabletop (talk through), failover (actually switch), simulation (drill), parallel processing (run both and compare)
- Backups
- Onsite and offsite, frequency, encryption, snapshots, replication, journaling (log every change), tested recovery
- Full, incremental, differential
- Everything; changes since the last backup of any kind (small, slow restore); changes since the last full (bigger, faster restore)
- Power
- UPS bridges to the generator; generator for long outages
Securing resources and monitoring 22
- Identification
- Vulnerability scans (credentialed sees more), application analysis static and dynamic, package monitoring, threat feeds (OSINT, proprietary, ISACs, dark web), penetration testing, responsible disclosure and bug bounty, system and process audits
- Analysis
- Confirm (false positive, false negative), prioritize with CVSS and CVE, classification, exposure factor, environmental variables, industry and organizational impact, risk tolerance
- Response
- Patch, cyber insurance, segmentation, compensating controls, documented exceptions and exemptions
- Validation
- Rescan, audit, verify
- Reporting
- Trends, open items, time to remediate
- None
- 0.0
- Low
- 0.1 to 3.9
- Medium
- 4.0 to 6.9
- High
- 7.0 to 8.9
- Critical
- 9.0 to 10.0
- Firewall rules, access lists, ports and protocols, screened subnets
- Allow only what is needed between zones
- IDS/IPS trends and signatures
- Detect known patterns; tune for trends
- Web filter
- Agent-based or centralized proxy; URL scanning, content categorization, block rules, reputation
- Operating system security
- Group Policy on Windows, SELinux on Linux
- Secure protocols
- Pick the encrypted port and transport: SSH not Telnet, HTTPS not HTTP, SFTP not FTP, SNMPv3, LDAPS, DoH or DoT
- DNS filtering
- Block known-bad domains at resolution
- Email security
- SPF (allowed senders), DKIM (signed mail), DMARC (policy for failures), email gateway
- File integrity monitoring
- Alert when critical files change
- DLP
- Prevent sensitive data from leaving by email, USB, or upload
- NAC
- Check device health before granting network access
- EDR and XDR
- Endpoint detection and response; extended across network and cloud
- User behavior analytics
- Baseline each user, alert on deviation
Identity and access management 12
- Provisioning and deprovisioning
- Create access on hire, remove it on exit; the classic offboarding failure is a still-active account
- Identity proofing
- Verify a person is who they claim before issuing credentials
- Federation
- One organization trusts another's identities
- SSO protocols
- SAML (XML, enterprise web SSO), OAuth (authorization delegation), OpenID Connect (authentication on OAuth), LDAP (directory), Kerberos (tickets, Windows domains)
- Attestation
- Confirming that a device or account state is what it claims
- Mandatory (MAC)
- Labels and clearances set by the system; users cannot change them; military
- Discretionary (DAC)
- The owner decides who gets access; file permissions
- Role-based (RBAC)
- Permissions attach to roles, users to roles
- Rule-based
- Fixed rules such as firewall ACLs or time limits
- Attribute-based (ABAC)
- Decisions from attributes: department, location, device, time
- Time-of-day restrictions
- Access only during set hours
- Least privilege
- Only what the job needs
Incident response and forensics 7
- Firewall logs
- Allowed and blocked connections
- Application logs
- Errors, logins, transactions
- Endpoint logs
- Processes, files, EDR alerts
- OS-specific logs
- Windows Event logs, Linux syslog and auth logs
- IPS/IDS logs
- Matched signatures
- Network logs, metadata
- Flows, DNS, headers
- Vulnerability scans, automated reports, dashboards, packet captures
- State, trends, and raw evidence
Governance, risk, and compliance 17
- Asset value (AV)
- What the asset is worth
- Exposure factor (EF)
- Fraction of value lost in one incident
- Single loss expectancy
- SLE = AV x EF
- Annualized rate of occurrence (ARO)
- How many times per year
- Annualized loss expectancy
- ALE = SLE x ARO
- Qualitative versus quantitative
- High/medium/low ratings versus dollars and probabilities
- Assessment cadence
- Ad hoc, recurring, one-time, continuous
- Risk register
- List of risks with key risk indicators, owners, and thresholds
- Risk tolerance and appetite
- How much variance is acceptable; appetite is expansionary, conservative, or neutral
- Strategies
- Transfer (insurance), accept (with exemption or exception), avoid (stop the activity), mitigate (add controls)
- Business impact analysis
- RTO (time to restore), RPO (data loss allowed), MTTR (mean repair time), MTBF (mean time between failures)
- SLA
- Measurable service levels and penalties
- MOA, MOU
- Agreement of intent; MOU less formal
- MSA
- Master agreement covering the relationship; work orders hang off it
- WO / SOW
- Work order or statement of work for one job
- NDA
- Confidentiality
- BPA
- Business partnership agreement: profits, responsibilities
Questions people ask
How many CompTIA Security+ SY0-701 flashcards are there?
369: 206 Acronyms, 9 The exam itself, 25 Cryptography, 19 Threat actors, vectors, and social engineering, 11 Vulnerabilities, 8 Attacks and indicators, 12 Security architecture, 9 Data protection, 12 Resilience and recovery, 22 Securing resources and monitoring, 12 Identity and access management, 7 Incident response and forensics, 17 Governance, risk, and compliance. They come from the course's cheat sheet and glossary, so what you drill is what the lessons teach.
Do I need an account?
No. The cards you mark as known are remembered in this browser only. Sign in to the course for progress that follows you between devices.