FR FieldReady Academy
Cheat sheet

Security+ SY0-701 Memorization Sheet

Print this and keep it beside you while you study. Security+ is a vocabulary exam: most questions describe a situation and ask for the exact term, control, or next step. Every table here is fair game.

Download the PDF Start the free course

01The exam itself

FactValue
Exam codeSY0-701 (Security+)
QuestionsUp to 90, multiple choice plus performance-based
Time90 minutes
Passing score750 on a scale of 100 to 900 (about 83%)
1.0 General Security Concepts12%
2.0 Threats, Vulnerabilities, and Mitigations22%
3.0 Security Architecture18%
4.0 Security Operations28%
5.0 Security Program Management and Oversight20%
Read for the qualifier: BEST, MOST likely, FIRST, NEXT, LEAST. Many answers are 'the least disruptive control that fixes the stated problem.'

02Security controls and core concepts

Control categoryWho or what applies itExamples
TechnicalSystems and softwareFirewalls, encryption, IDS, ACLs, MFA
ManagerialPolicy and oversightRisk assessments, security policies, awareness program planning
OperationalPeople carrying out proceduresGuards, awareness training delivery, incident response steps, backups
PhysicalThe building and hardwareLocks, fences, bollards, badges, cameras, lighting
Control typePurposeExamples
PreventiveStop it before it happensFirewall rule, door lock, least privilege
DeterrentDiscourage the attemptWarning signs, visible cameras, login banners
DetectiveNotice it happenedIDS, logs, audits, motion sensors, cameras reviewed later
CorrectiveUndo the damageRestore from backup, patch after incident, incident response
CompensatingAlternative when the ideal control is not possibleExtra monitoring on a system that cannot be patched
DirectiveTell people what to doPolicies, procedures, acceptable use, signage
  • CIA: Confidentiality (encryption, access control), Integrity (hashing, signatures, change control), Availability (redundancy, backups, DDoS protection)
  • Non-repudiation: the sender cannot deny sending; digital signatures
  • AAA: Authentication (who you are), Authorization (what you may do), Accounting (what you did). Authenticating systems as well as people (certificates, 802.1X)
  • Gap analysis: where you are versus where the framework or policy says you should be
  • Deception: honeypot (decoy system), honeynet (decoy network), honeyfile (bait document), honeytoken (fake credential or record that alerts when used)
Zero trust componentPlaneJob
Policy engineControl planeDecides allow or deny for each request
Policy administratorControl planeTells the enforcement point what the engine decided
Adaptive identityControl planeAuthentication strength changes with context (location, device, behavior)
Threat scope reductionControl planeLimit what any identity can reach
Policy-driven access controlControl planeRules, not network location, grant access
Policy enforcement pointData planeWhere the allow or deny is applied to traffic
Implicit trust zonesData planeSmall zones where traffic is allowed after verification
Subject and systemData planeThe user or device asking, and the resource

Physical security

  • Bollards stop vehicles. Fencing sets the perimeter. Lighting deters and helps cameras
  • Access control vestibule (mantrap): two doors, one opens at a time, stops tailgating
  • Access badge, security guard, video surveillance
  • Sensors: infrared (body heat), pressure (weight on a floor or mat), microwave (motion by reflected waves), ultrasonic (motion by sound)

03Change management

  • Business process: approval process, ownership, stakeholders, impact analysis, test results, backout plan, maintenance window, standard operating procedure
  • Technical implications: allow lists and deny lists, restricted activities, downtime, service and application restarts, legacy applications, dependencies
  • Documentation: update diagrams, policies, and procedures. Version control tracks every change and lets you roll back
  • Order in a question: request and impact analysis, approval, schedule the window, test, implement with a backout plan ready, document

04Cryptography

ConceptDetail
SymmetricOne shared key encrypts and decrypts. Fast, bulk data. AES (128, 192, 256-bit), 3DES (legacy), ChaCha20, Blowfish
AsymmetricPublic key encrypts or verifies, private key decrypts or signs. Slow, used for key exchange and signatures. RSA, ECC (smaller keys, same strength), DSA, ECDSA
Key exchangeDiffie-Hellman and ECDHE agree on a shared key over an open channel. Ephemeral keys give perfect forward secrecy
HashingOne-way fixed-length fingerprint: MD5 128-bit (broken), SHA-1 160-bit (deprecated), SHA-256, SHA-3. HMAC adds a key for authenticity
SaltingRandom data added to a password before hashing so identical passwords hash differently and rainbow tables fail
Key stretchingMake hashing slow on purpose: PBKDF2, bcrypt, scrypt, Argon2
Digital signatureHash the message, encrypt the hash with the private key. Proves integrity, authenticity, and non-repudiation
Key lengthLonger is stronger; AES-256 over AES-128, RSA 2048 minimum, ECC 256 is comparable to RSA 3072
BlockchainOpen public ledger: chained hashed blocks, tamper-evident, distributed
Transport encryptionTLS 1.2 and 1.3 for web and mail, IPsec for VPNs, SSH for shells. Deprecated: SSL, TLS 1.0 and 1.1
Encryption levelWhat is protected
Full-diskThe whole drive; protects a lost laptop
Partition or volumeOne partition or logical volume
FileIndividual files
DatabaseThe whole database
RecordIndividual fields or rows, such as card numbers

Tools and obfuscation

  • TPM: chip on the motherboard that stores keys and measures boot; used by full-disk encryption
  • HSM: dedicated hardware appliance or card for key storage and crypto operations at scale
  • KMS: key management service, usually cloud, for creating, rotating, and controlling keys
  • Secure enclave: isolated processor area for secrets on phones and laptops
  • Key escrow: a trusted third party holds a copy of the key for recovery
  • Steganography hides data inside images or audio. Tokenization replaces data with a token mapped in a vault. Data masking shows only part (xxxx-1234)
PKI termMeaning
Certificate authority (CA)Issues and signs certificates; the root of trust
Registration authorityVerifies identity before the CA issues
CSRCertificate signing request: the public key plus identity sent to the CA
CRLCertificate revocation list, downloaded periodically; can be stale
OCSPReal-time revocation check of one certificate; OCSP stapling has the server include a fresh response
Self-signedNot signed by a trusted CA; browsers warn; internal use only
Third-partyIssued by a public CA; trusted by browsers
Wildcard*.example.com covers every subdomain at one level
SANSubject alternative name: several names on one certificate
FormatsPEM (Base64 text, .crt .pem), DER (binary), PFX or P12 (with private key), P7B (chain, no private key)

05Threat actors, vectors, and social engineering

ActorTypical traitsTypical motivation
Nation-stateExternal, well funded, highly sophisticated, patient (APT)Espionage, war, disruption
Organized crimeExternal, funded, sophisticatedFinancial gain: ransomware, fraud
HacktivistExternal, modest resourcesPhilosophical or political, service disruption
Insider threatInternal, has access alreadyRevenge, financial gain, or accidental
Unskilled attackerExternal, low sophistication, uses others' toolsChaos, notoriety
Shadow ITInternal, not maliciousConvenience; creates unmanaged risk

Motivations to recognize

  • Data exfiltration, espionage, service disruption, blackmail, financial gain, philosophical or political beliefs, ethical (white hat), revenge, disruption or chaos, war
VectorExamples
Message-basedEmail, SMS, instant messaging
Image-based and file-basedMalicious images, macros in documents, executables
Voice callVishing
Removable deviceUSB drops
Vulnerable softwareClient-based (agent installed) versus agentless
Unsupported systemsEnd-of-life operating systems and applications
Unsecure networksOpen wireless, unmanaged wired ports, Bluetooth
Open service ports, default credentialsExposed services, unchanged admin passwords
Supply chainManaged service providers, vendors, suppliers
Human vectorOne-line definition
PhishingFraudulent email to steal credentials or deliver malware
Vishing, smishingThe same by voice call, by text message
Spear phishing, whalingTargeted at a person; targeted at an executive
Business email compromiseAttacker uses or imitates a real business account to redirect payments
PretextingAn invented story that justifies the request
Impersonation, brand impersonationPretending to be a person; pretending to be a company
Watering holeCompromise a site the targets already visit
TyposquattingLook-alike domain names catching mistyped URLs
Misinformation, disinformationFalse content spread unknowingly; spread deliberately
Tailgating, shoulder surfing, dumpster divingFollowing through a door; watching a screen; reading the trash

06Vulnerabilities

ClassMembers to recognize
ApplicationMemory injection, buffer overflow, race conditions (time-of-check to time-of-use), malicious update
Operating systemUnpatched services, weak defaults
Web-basedSQL injection (' OR 1=1), cross-site scripting (script in a page other users load)
HardwareFirmware flaws, end-of-life, legacy devices
VirtualizationVM escape (guest reaches the host), resource reuse (data left in reallocated memory or storage)
Cloud-specificMisconfigured storage, shared-tenant risks, exposed APIs
Supply chainService provider, hardware provider, software provider
CryptographicWeak or deprecated algorithms, short keys, bad implementations
MisconfigurationOpen ports, default settings, excessive permissions
MobileSide loading (apps from outside the store), jailbreaking or rooting
Zero-dayKnown to attackers before a patch exists

07Attacks and indicators

MalwareTell
RansomwareFiles encrypted, payment demanded
TrojanHidden inside a wanted program; remote access trojan gives control
WormSpreads by itself across the network
VirusAttaches to files, needs a user action to spread
Spyware, keyloggerWatches activity; records keystrokes
BloatwareUnwanted preinstalled software, expands attack surface
Logic bombTriggers on a date or event
RootkitHides at kernel or firmware level; survives reboots, evades antivirus
AttackTellDefense
DDoS (amplified, reflected)Floods from many sources; small requests to third parties produce large responses at the victimUpstream scrubbing, rate limiting
DNS attacksPoisoned cache, spoofed answers, domain hijackingDNSSEC, DNS filtering
Wireless attacksEvil twin, deauthentication, rogue APWPA3, 802.1X, protected management frames
On-pathAttacker between the parties reads or alters trafficTLS, VPN, certificate pinning
Credential replayCaptured authentication reusedSession tokens, nonces, MFA
InjectionUntrusted input executed by a database, shell, or LDAPInput validation, parameterized queries
Buffer overflowInput longer than the buffer overwrites memoryPatching, memory-safe code, ASLR
Privilege escalationNormal user gains adminLeast privilege, patching
Forgery (CSRF, SSRF)Victim's browser or the server is tricked into making a requestAnti-forgery tokens, input validation
Directory traversal../../ in a path reaches files outside the web rootInput validation, least privilege
DowngradeForces a weaker protocol or cipherDisable legacy protocols
Collision, birthdayTwo inputs with the same hash; probability grows fast with attemptsStrong hashes (SHA-256+)
Password sprayingOne common password tried against many accountsMFA, lockout tuned for spraying
Brute forceEvery combination against one accountLockout, length, MFA
RFID cloning, brute force on locks, environmentalPhysical attacksPhysical controls, monitoring

Indicators of malicious activity

  • Account lockout, concurrent session usage, impossible travel (logins from two distant places in minutes)
  • Blocked content, resource consumption spikes, resources becoming inaccessible
  • Out-of-cycle logging, missing logs (attacker cleared them), published or documented exploits for your versions

Mitigation techniques

  • Segmentation; access control (ACLs, permissions); application allow lists; isolation; patching; encryption; monitoring; least privilege; configuration enforcement; decommissioning
  • Hardening: encryption, endpoint protection, host-based firewall, host-based IPS, disable unused ports and protocols, change default passwords, remove unnecessary software

08Security architecture

Architecture models

  • Cloud responsibility matrix: the provider secures the infrastructure; the customer secures data, identities, and configuration. Hybrid and third-party vendors add shared responsibility
  • Infrastructure as code: environments defined in files; serverless: provider runs the function; microservices: many small services with APIs
  • Network: physical isolation (air gap), logical segmentation (VLANs, subnets), software-defined networking
  • On-premises versus cloud; centralized versus decentralized; containerization (shared kernel) versus virtualization (hypervisor)
  • IoT, ICS/SCADA (industrial control), RTOS (real-time), embedded systems: hard to patch, isolate them
  • Considerations: availability, resilience, cost, responsiveness, scalability, ease of deployment, risk transference, ease of recovery, patch availability, inability to patch, power, compute
Infrastructure conceptDetail
Security zonesTrusted, untrusted, screened subnet (DMZ) for public-facing servers
Attack surfaceEverything reachable; shrink it
Fail-open versus fail-closedFail-open keeps traffic flowing when the control fails (availability); fail-closed blocks (security)
Active versus passiveInline (can block, can bottleneck) versus tap or monitor port (sees a copy, alerts only)
Jump serverHardened host you go through to reach protected systems
Proxy serverForward proxy for clients; reverse proxy in front of servers
IPS versus IDSInline and blocks versus out of band and alerts
Load balancerSpreads traffic; active-active or active-passive
SensorsCollect traffic or logs for monitoring
Port security802.1X authentication on switch ports and Wi-Fi, using EAP (EAP-TLS with certificates is strongest; PEAP, EAP-TTLS, EAP-FAST)
Firewall typesWAF (Layer 7, protects web apps), UTM (all-in-one), NGFW (application-aware, user-aware), Layer 4 (ports) versus Layer 7 (content)
Secure communicationVPN and remote access; tunneling with TLS or IPsec; SD-WAN; SASE (network plus cloud security)

09Data protection

Data typeMeaning
RegulatedLaw or regulation governs it: health, payment card, personal data
Trade secret, intellectual propertyFormulas, source code, designs
Legal information, financial informationContracts, litigation; ledgers, filings
Human-readable versus non-human-readableDocuments versus binaries and encrypted blobs
ClassificationTypical use
PublicAnyone may see it
Private, sensitiveInternal; harm if leaked
ConfidentialLimited to those who need it
RestrictedTightly controlled, often regulated
CriticalThe organization cannot function without it
  • States: at rest (disk, database), in transit (network), in use (memory, being processed)
  • Data sovereignty: data is subject to the laws of the country where it is stored. Geolocation and geographic restrictions control where data may live or be accessed from
  • Methods: encryption, hashing, masking, tokenization, obfuscation, segmentation, permission restrictions

10Resilience and recovery

ConceptDetail
Load balancing versus clusteringSpreads requests across servers; servers act as one system with failover
Hot siteRunning mirror, minutes to switch, most expensive
Warm siteEquipment ready, data restored on failover, hours
Cold siteSpace and power only, days
Geographic dispersionSites far enough apart that one disaster cannot hit both
Platform diversity, multi-cloudDifferent vendors so one flaw or outage does not take everything
Continuity of operationsKeep the business running through the incident
Capacity planningPeople, technology, infrastructure sized for growth and surge
TestingTabletop (talk through), failover (actually switch), simulation (drill), parallel processing (run both and compare)
BackupsOnsite and offsite, frequency, encryption, snapshots, replication, journaling (log every change), tested recovery
Full, incremental, differentialEverything; changes since the last backup of any kind (small, slow restore); changes since the last full (bigger, faster restore)
PowerUPS bridges to the generator; generator for long outages
RAIDHow it worksSurvives
RAID 0Striping, no redundancyNothing; speed only
RAID 1MirroringOne disk failure
RAID 5Striping with distributed parity, 3+ disksOne disk
RAID 6Striping with double parity, 4+ disksTwo disks
RAID 10Mirrored pairs, stripedOne disk per mirror

11Securing resources and monitoring

Baselines, hardening, wireless, mobile, applications

  • Secure baseline: establish it, deploy it, maintain it (drift detection)
  • Hardening targets: mobile devices, workstations, switches, routers, cloud infrastructure, servers, ICS/SCADA, embedded and RTOS, IoT
  • Wireless: site survey and heat map first; WPA3; enterprise authentication with AAA and RADIUS; EAP-TLS strongest
  • Mobile: MDM enforces policy; deployment models BYOD (personal), COPE (company owned, personally enabled), CYOD (choose from a list); connections cellular, Wi-Fi, Bluetooth
  • Application security: input validation, secure cookies, static code analysis, code signing; sandboxing runs untrusted code in isolation

Asset management

  • Acquisition and procurement, assignment and ownership, classification, monitoring and asset tracking (inventory, enumeration)
  • Disposal: sanitization (wipe so data cannot be recovered), destruction (shred, degauss, pulverize), certification (proof it was done), data retention rules first
Vulnerability management stepContents
IdentificationVulnerability scans (credentialed sees more), application analysis static and dynamic, package monitoring, threat feeds (OSINT, proprietary, ISACs, dark web), penetration testing, responsible disclosure and bug bounty, system and process audits
AnalysisConfirm (false positive, false negative), prioritize with CVSS and CVE, classification, exposure factor, environmental variables, industry and organizational impact, risk tolerance
ResponsePatch, cyber insurance, segmentation, compensating controls, documented exceptions and exemptions
ValidationRescan, audit, verify
ReportingTrends, open items, time to remediate
CVSS ratingScore
None0.0
Low0.1 to 3.9
Medium4.0 to 6.9
High7.0 to 8.9
Critical9.0 to 10.0

Monitoring tools

  • Log aggregation, alerting, scanning, reporting, archiving; alert response and remediation (quarantine); alert tuning to cut false positives
  • SCAP: automated compliance checking against benchmarks (CIS). Agents versus agentless collection
  • SIEM correlates logs; antivirus; DLP stops data leaving; SNMP traps push device alerts; NetFlow shows who talked to whom; vulnerability scanners
Enterprise capabilityOne-line job
Firewall rules, access lists, ports and protocols, screened subnetsAllow only what is needed between zones
IDS/IPS trends and signaturesDetect known patterns; tune for trends
Web filterAgent-based or centralized proxy; URL scanning, content categorization, block rules, reputation
Operating system securityGroup Policy on Windows, SELinux on Linux
Secure protocolsPick the encrypted port and transport: SSH not Telnet, HTTPS not HTTP, SFTP not FTP, SNMPv3, LDAPS, DoH or DoT
DNS filteringBlock known-bad domains at resolution
Email securitySPF (allowed senders), DKIM (signed mail), DMARC (policy for failures), email gateway
File integrity monitoringAlert when critical files change
DLPPrevent sensitive data from leaving by email, USB, or upload
NACCheck device health before granting network access
EDR and XDREndpoint detection and response; extended across network and cloud
User behavior analyticsBaseline each user, alert on deviation

12Identity and access management

ConceptDetail
Provisioning and deprovisioningCreate access on hire, remove it on exit; the classic offboarding failure is a still-active account
Identity proofingVerify a person is who they claim before issuing credentials
FederationOne organization trusts another's identities
SSO protocolsSAML (XML, enterprise web SSO), OAuth (authorization delegation), OpenID Connect (authentication on OAuth), LDAP (directory), Kerberos (tickets, Windows domains)
AttestationConfirming that a device or account state is what it claims
Access control modelRule
Mandatory (MAC)Labels and clearances set by the system; users cannot change them; military
Discretionary (DAC)The owner decides who gets access; file permissions
Role-based (RBAC)Permissions attach to roles, users to roles
Rule-basedFixed rules such as firewall ACLs or time limits
Attribute-based (ABAC)Decisions from attributes: department, location, device, time
Time-of-day restrictionsAccess only during set hours
Least privilegeOnly what the job needs

MFA and passwords

  • Factors: something you know (password, PIN), something you have (token, phone, smart card, security key), something you are (biometrics), somewhere you are (location)
  • Tokens: hard (device), soft (app), security keys (FIDO2). Biometrics have false acceptance and false rejection rates
  • Password policy: length beats complexity, no reuse, expiration and age rules, password managers, passwordless with keys or biometrics
  • Privileged access management: just-in-time permissions, password vaulting, ephemeral (temporary) credentials

Automation and orchestration

  • Use cases: user and resource provisioning, guard rails, security groups, ticket creation and escalation, enabling and disabling services, continuous integration and testing, integrations and APIs
  • Benefits: efficiency, enforced baselines, secure scaling, employee retention, reaction time, workforce multiplier
  • Considerations: complexity, cost, single point of failure, technical debt, ongoing supportability

13Incident response and forensics

Incident response process, in order

  • 1. Preparation: plans, tools, training, contacts.
  • 2. Detection: notice that something happened.
  • 3. Analysis: confirm and scope it.
  • 4. Containment: stop the spread (isolate, block).
  • 5. Eradication: remove the cause (malware, accounts, vulnerability).
  • 6. Recovery: restore systems and monitor.
  • 7. Lessons learned: review and improve.
  • Training and testing: tabletop exercises and simulations
  • Root cause analysis finds why, not just what. Threat hunting searches proactively for signs an alert missed
  • Forensics: legal hold (preserve, do not delete), chain of custody (who handled evidence, when), acquisition (image it), preservation, reporting, e-discovery
  • Order of volatility (collect first): CPU cache and registers, RAM, swap and temporary files, disk, remote logs, archives and backups
Data sourceWhat it tells you
Firewall logsAllowed and blocked connections
Application logsErrors, logins, transactions
Endpoint logsProcesses, files, EDR alerts
OS-specific logsWindows Event logs, Linux syslog and auth logs
IPS/IDS logsMatched signatures
Network logs, metadataFlows, DNS, headers
Vulnerability scans, automated reports, dashboards, packet capturesState, trends, and raw evidence

14Governance, risk, and compliance

DocumentWhat it isExamples
PolicyWhat must be done, high levelAcceptable use, information security, business continuity, disaster recovery, incident response, SDLC, change management
StandardSpecific mandatory settingsPassword, access control, physical security, encryption
ProcedureStep by step howChange management steps, onboarding and offboarding, playbooks
GuidelineRecommended, not mandatoryBest-practice advice
  • External considerations: regulatory, legal, industry, local and regional, national, global. Monitoring and revision keep documents current
  • Governance structures: boards, committees, government entities; centralized versus decentralized
  • Data roles: owner (accountable), controller (decides why and how personal data is processed), processor (processes on the controller's behalf), custodian or steward (day-to-day handling and quality)
Risk termDefinition or formula
Asset value (AV)What the asset is worth
Exposure factor (EF)Fraction of value lost in one incident
Single loss expectancySLE = AV x EF
Annualized rate of occurrence (ARO)How many times per year
Annualized loss expectancyALE = SLE x ARO
Qualitative versus quantitativeHigh/medium/low ratings versus dollars and probabilities
Assessment cadenceAd hoc, recurring, one-time, continuous
Risk registerList of risks with key risk indicators, owners, and thresholds
Risk tolerance and appetiteHow much variance is acceptable; appetite is expansionary, conservative, or neutral
StrategiesTransfer (insurance), accept (with exemption or exception), avoid (stop the activity), mitigate (add controls)
Business impact analysisRTO (time to restore), RPO (data loss allowed), MTTR (mean repair time), MTBF (mean time between failures)
AgreementUse
SLAMeasurable service levels and penalties
MOA, MOUAgreement of intent; MOU less formal
MSAMaster agreement covering the relationship; work orders hang off it
WO / SOWWork order or statement of work for one job
NDAConfidentiality
BPABusiness partnership agreement: profits, responsibilities

Third-party risk

  • Vendor assessment: penetration testing, right-to-audit clause, evidence of internal audits, independent assessments, supply chain analysis
  • Vendor selection: due diligence, conflict of interest. Ongoing: monitoring, questionnaires, rules of engagement

Compliance and privacy

  • Reporting: internal and external. Consequences: fines, sanctions, reputational damage, loss of license, contractual impacts
  • Monitoring: due diligence and due care, attestation and acknowledgement, internal and external, automation
  • Privacy: legal implications at local, regional, national, global levels; data subject; controller versus processor; ownership; data inventory and retention; right to be forgotten

Audits, assessments, penetration testing

  • Attestation; internal (compliance, audit committee, self-assessments); external (regulatory, examinations, assessment, independent third-party audit)
  • Pen test types: physical, offensive (red), defensive (blue), integrated (purple)
  • Environment knowledge: known (full information, white box), partially known (some, gray box), unknown (none, black box)
  • Reconnaissance: passive (public sources, no contact) versus active (scanning the target)

Security awareness

  • Phishing campaigns and recognizing and reporting attempts; anomalous behavior recognition (risky, unexpected, unintentional)
  • User guidance: policies and handbooks, situational awareness, insider threat, password management, removable media and cables, social engineering, operational security, hybrid and remote work
  • Reporting and monitoring: initial and recurring; program development and execution

15Ports and secure protocol pairs

InsecurePortSecure replacementPort
HTTP80HTTPS (TLS)443
FTP20, 21SFTP (over SSH); FTPS22; 989, 990
Telnet23SSH22
SMTP25SMTPS or submission with TLS465, 587
POP3110POP3S995
IMAP143IMAPS993
LDAP389LDAPS636
SNMP v1, v2c161, 162SNMPv3 (same ports, adds auth and encryption)161, 162
DNS53DNS over TLS; DNS over HTTPS853; 443
NTP123NTS123
RTP (voice)dynamicSRTPdynamic
SIP5060SIP over TLS5061
  • Other ports: DHCP 67/68, TFTP 69, Kerberos 88, RDP 3389, SMB 445, syslog 514, RADIUS 1812/1813, TACACS+ TCP 49, SQL Server 1433, MySQL 3306, IKE 500 and NAT-T 4500
  • IPsec: AH integrity only, ESP encryption, IKE negotiates keys; transport mode protects the payload, tunnel mode wraps the whole packet
  • Email authentication: SPF lists allowed sending servers, DKIM signs messages, DMARC says what to do when they fail
  • Wireless: WEP broken, WPA deprecated, WPA2 AES, WPA3 SAE; enterprise mode uses 802.1X with RADIUS

16Acronyms

Every acronym used in this course, 206 in all.

AcronymStands forMeaning
3DESTriple Data Encryption StandardDES applied three times; legacy and slow, replaced by AES.
802.1XIEEE 802.1XPort-based network access control: a device must authenticate before the switch port or Wi-Fi passes traffic.
AAAAuthentication, authorization, and accountingProve who you are, decide what you may do, record what you did.
ABACAttribute-based access controlAccess decisions based on attributes of the user, resource, and context, such as time and location.
ACLAccess control listAn ordered list of permit and deny rules on a router, firewall, or file system.
AESAdvanced Encryption StandardThe standard symmetric cipher, with 128, 192, or 256-bit keys.
AES-128AES with a 128-bit keyThe standard-strength AES, secure and fast.
AES-256AES with a 256-bit keyThe high-strength AES used for data at rest and sensitive sessions.
AES-CCMPAES in CCMP modeThe AES-based encryption WPA2 uses for Wi-Fi.
AHAuthentication HeaderThe IPsec protocol that provides integrity and authentication without encryption.
ALEAnnualized loss expectancyThe expected yearly cost of a risk: SLE times ARO.
APAccess pointThe radio that bridges Wi-Fi clients onto the wired network.
APIApplication programming interfaceThe defined way one program talks to another, such as the web endpoints a cloud service exposes.
APTAdvanced persistent threatA well-funded, skilled, patient attacker, usually a nation-state, that stays hidden for a long time.
AROAnnualized rate of occurrenceHow many times per year an incident is expected to happen.
ARPAddress Resolution ProtocolFinds the MAC address that goes with a known IPv4 address on the local segment.
ASLRAddress space layout randomizationRandomizes where programs load in memory so exploits cannot predict addresses.
AUPAcceptable use policyThe rules for how staff may use company systems and data.
AVAsset valueWhat an asset is worth, the first number in quantitative risk analysis (SLE = AV x EF).
AVAntivirusSoftware that detects, quarantines, and removes malware using signatures, heuristics, and behavior.
BECBusiness email compromiseFraud by email impersonating an executive or vendor to redirect payments.
BIABusiness impact analysisIdentifies critical functions and what an outage of each would cost, setting RTO and RPO.
BPABusiness partnership agreementHow partners share responsibilities, profits, and liabilities.
BYODBring your own deviceStaff use personal phones and laptops for work.
CACertificate authorityThe trusted entity that signs certificates.
CEOChief executive officerThe top executive; the person impersonated in whaling and business email compromise.
CFOChief financial officerThe executive in charge of money; a common target and impersonation in payment fraud.
CIContinuous integrationEvery code change is automatically built and tested when it is committed.
CIAConfidentiality, integrity, and availabilityThe three goals of security: keep data secret, keep it correct, keep it reachable.
CISCenter for Internet SecurityThe organization that publishes hardening benchmarks and the CIS Controls.
COPECorporate-owned, personally enabledThe company buys the device and lets staff use it personally.
CPUCentral processing unitThe processor that executes instructions.
CRLCertificate revocation listA signed list of revoked certificate serial numbers published by a CA.
CSRCertificate signing requestThe file containing a public key and identity that you send to a CA to get a certificate.
CSRFCross-site request forgeryTricks a logged-in user's browser into sending a request the user did not intend.
CVECommon Vulnerabilities and ExposuresThe public identifier for a known vulnerability, such as CVE-2024-12345.
CVSSCommon Vulnerability Scoring SystemA 0 to 10 severity score for a vulnerability.
CYODChoose your own deviceStaff pick from a list of approved devices the company then owns and manages.
DACDiscretionary access controlThe owner of a resource decides who may access it.
DBADatabase administratorThe person who runs the database servers.
DDoSDistributed denial of serviceMany sources, usually a botnet, flood a target at once.
DERDistinguished Encoding RulesThe binary format for certificates and keys.
DESData Encryption StandardThe 1970s 56-bit block cipher; broken by brute force, do not use.
DHCPDynamic Host Configuration ProtocolHands out IP addresses, masks, gateways, and DNS servers automatically (UDP 67 and 68).
DKIMDomainKeys Identified MailOutgoing mail is digitally signed; the public key is published in DNS.
DLPData loss preventionTools that detect and block sensitive data leaving by email, web, USB, or cloud.
DMARCDomain-based Message Authentication, Reporting, and ConformanceA DNS policy telling receivers what to do with mail that fails SPF or DKIM, and where to send reports.
DMZDemilitarized zoneA screened subnet between the internet and the internal network for public-facing servers.
DNSDomain Name SystemTranslates names such as www.example.com into IP addresses (UDP 53, TCP 53 for zone transfers).
DNSSECDNS Security ExtensionsDigital signatures on DNS records so a resolver can tell an answer was not forged.
DoHDNS over HTTPSDNS queries carried inside HTTPS on TCP 443 so they cannot be read or altered in transit.
DoSDenial of serviceOne source floods or crashes a target so it cannot serve users.
DoTDNS over TLSDNS queries encrypted with TLS on TCP 853.
DSADigital Signature AlgorithmA government-standard signature algorithm; used less than RSA and ECDSA today.
EAPExtensible Authentication ProtocolThe framework that carries authentication methods inside 802.1X.
EAP-FASTEAP Flexible Authentication via Secure TunnelingCisco's tunneled EAP method using a protected access credential instead of a certificate.
EAP-TLSEAP with Transport Layer SecurityCertificate-based authentication on both sides; the strongest Wi-Fi and wired 802.1X method.
EAP-TTLSEAP with Tunneled TLSA server certificate builds a TLS tunnel, then the client authenticates inside it with a password or other method.
ECCElliptic curve cryptographyPublic-key cryptography that gives RSA-level strength with much shorter keys, ideal for phones and IoT.
ECDHEElliptic Curve Diffie-Hellman EphemeralKey exchange with a fresh elliptic curve key per session, giving forward secrecy.
ECDSAElliptic Curve Digital Signature AlgorithmDigital signatures using elliptic curve keys.
EDREndpoint detection and responseEndpoint agents that record activity, detect attacks, and let responders isolate and clean the machine.
EFExposure factorThe fraction of an asset's value lost in one incident.
ESPEncapsulating Security PayloadThe IPsec protocol that encrypts and authenticates the payload.
FIDO2Fast Identity Online 2Passwordless or second-factor authentication with a hardware security key or device biometrics.
FIMFile integrity monitoringAlerts when critical files or configurations change.
FTPFile Transfer ProtocolPlaintext file transfer on TCP 21 (control) and 20 (data); replace with SFTP or FTPS.
FTPSFTP SecureFTP wrapped in TLS, ports 990 and 989 (implicit) or 21 with an upgrade (explicit).
GBGigabyteAbout a billion bytes; the unit for RAM, storage, and data caps.
GCMPGalois/Counter Mode ProtocolThe stronger AES encryption mode used by WPA3.
GPSGlobal Positioning SystemSatellite positioning, also used as a stratum 0 time reference.
HMACHash-based message authentication codeA keyed hash that proves a message came from someone with the key and was not altered.
HRHuman resourcesThe department that hires and separates staff; its system should drive account provisioning and removal.
HSMHardware security moduleA tamper-resistant appliance or card that generates, stores, and uses cryptographic keys.
HTTPHypertext Transfer ProtocolWeb traffic in the clear on TCP 80.
HTTPSHypertext Transfer Protocol SecureHTTP inside TLS on TCP 443.
IaaSInfrastructure as a serviceThe provider supplies virtual machines, storage, and networks; you manage the operating system and up.
IaCInfrastructure as codeDefining networks and servers in files that tools build automatically and repeatably.
ICSIndustrial control systemThe general term for computers that run physical processes; SCADA is one kind.
IDIdentifier or identificationA name or number that uniquely labels a user, device, session, or record.
IDSIntrusion detection systemWatches a copy of the traffic and alerts on attacks; cannot block them.
IKEInternet Key ExchangeNegotiates the keys and security associations for IPsec; UDP 500, and 4500 through NAT.
IMAPInternet Message Access ProtocolReads mail that stays on the server, synced across devices; TCP 143, secure 993.
IMAPSIMAP SecureIMAP over TLS on TCP 993.
iOSiPhone operating systemApple's mobile operating system for iPhone.
IoTInternet of ThingsNetworked devices such as cameras, sensors, thermostats, and smart TVs.
IPInternet ProtocolThe Layer 3 protocol that addresses and routes packets between networks.
IPSIntrusion prevention systemSits inline and blocks attacks as they pass.
IPsecInternet Protocol SecurityThe suite that encrypts and authenticates IP packets for VPNs.
ISACInformation sharing and analysis centerAn industry group where members share threat intelligence.
ITInformation technologyComputers, networks, and the people who run them.
KMSKey management serviceA managed, usually cloud-hosted, service that creates, stores, rotates, and controls access to encryption keys.
LACPLink Aggregation Control ProtocolNegotiates bundling several physical links into one logical link (802.1AX, formerly 802.3ad).
LANLocal area networkOne site's network: a building, floor, or campus that one organization owns and runs.
LDAPLightweight Directory Access ProtocolQueries a directory such as Active Directory for users and groups; TCP 389, secure 636.
LDAPSLDAP SecureLDAP over TLS on TCP 636.
LTELong-Term Evolution4G cellular data; the workhorse mobile broadband standard.
MACMedia access control (address)The 48-bit Layer 2 hardware address of a network interface, which a switch uses to forward frames.
MACMandatory access controlThe access control model where the system assigns classification labels that users cannot change.
MD5Message Digest 5A 128-bit hash that is broken: collisions can be manufactured; recognize, never recommend.
MDMMobile device managementSoftware that enrolls phones and tablets and enforces policy: passcodes, encryption, apps, remote wipe.
MFAMulti-factor authenticationTwo or more different kinds of proof: something you know, have, are, or where you are.
MIMEMultipurpose Internet Mail ExtensionsThe standard that lets email carry attachments and non-text content.
MOAMemorandum of agreementA more formal, sometimes binding, statement of what parties agree to do.
MOUMemorandum of understandingA non-binding statement of intent and roles between parties.
MPLSMultiprotocol Label SwitchingA provider WAN that forwards by short labels instead of IP lookups, with traffic engineering and QoS.
msMillisecondOne thousandth of a second; latency and response times.
MSAMaster service agreementThe umbrella contract covering a whole vendor relationship; individual jobs hang off it.
MTBFMean time between failuresThe average running time before a component fails; a reliability measure.
MTTRMean time to repairThe average time to fix a failure and restore service.
NACNetwork access controlChecks a device's identity and health before letting it onto the network.
NAT-TNAT traversalWraps IPsec in UDP 4500 so it can pass through address translation.
NDANon-disclosure agreementA contract that keeps shared information confidential.
NGFWNext-generation firewallA firewall that identifies applications and users, and includes intrusion prevention.
NTPNetwork Time ProtocolSynchronizes clocks across the network (UDP 123); wrong time breaks Kerberos, certificates, and logs.
NTSNetwork Time SecurityAuthentication and integrity for NTP so time cannot be spoofed.
OAuthOpen AuthorizationLets a user grant an application limited access to their account on another service without sharing the password.
OCSPOnline Certificate Status ProtocolA real-time query to the CA asking whether one certificate is revoked.
OSOperating systemThe software that manages hardware and runs applications: Windows, macOS, Linux, iOS, Android.
OSINTOpen-source intelligenceInformation gathered from public sources: websites, social media, records, DNS.
P7BPKCS #7 bundleA file holding a certificate chain with no private key.
PBKDF2Password-Based Key Derivation Function 2Stretches a password with many hash rounds so guessing is slow.
PEAPProtected EAPA server certificate creates a TLS tunnel and the user's password is checked inside it.
PEMPrivacy Enhanced Mail (format)The Base64 text format for certificates and keys, with BEGIN and END lines.
PFXPersonal Information ExchangeA password-protected bundle holding a certificate and its private key (also .p12).
PINPersonal identification numberA short numeric secret, a something-you-know factor.
PKIPublic key infrastructureThe system of certificate authorities, certificates, and revocation that makes public keys trustworthy.
POP3Post Office Protocol version 3Downloads mail to one device and usually deletes it from the server; TCP 110, secure 995.
POP3SPOP3 SecurePOP3 over TLS on TCP 995.
PSKPre-shared keyOne shared passphrase for everyone on a Wi-Fi network (Personal mode).
RARegistration authorityThe part of a PKI that verifies identities before the CA signs.
RADIUSRemote Authentication Dial-In User ServiceThe AAA server behind Wi-Fi Enterprise, VPNs, and 802.1X; UDP 1812 and 1813.
RAIDRedundant array of independent disksCombining disks for speed, capacity, or fault tolerance: 0 stripe, 1 mirror, 5 stripe with parity, 6 double parity, 10 mirrored stripes.
RAMRandom-access memoryThe working memory that holds running programs and data; lost at power off.
RATRemote access trojanMalware that opens a back door so an attacker can control the machine.
RBACRole-based access controlPermissions are assigned to roles, and users get roles.
RC4Rivest Cipher 4A fast stream cipher used in WEP and old TLS; broken and deprecated.
RDPRemote Desktop ProtocolMicrosoft's remote graphical desktop on TCP 3389.
RFIDRadio-frequency identificationTags read by radio for badges, inventory, and asset tracking.
RPORecovery point objectiveThe maximum acceptable data loss, measured in time.
RSARivest, Shamir, AdlemanThe classic public-key algorithm for encryption and digital signatures.
RTORecovery time objectiveThe maximum acceptable time to restore a service after failure.
RTOSReal-time operating systemAn operating system that guarantees responses within strict time limits, used in embedded and control devices.
RTPReal-time Transport ProtocolCarries the actual voice and video packets of a call, over UDP.
SaaSSoftware as a serviceComplete applications delivered over the web, such as email and office suites.
SAESimultaneous authentication of equalsThe WPA3 Personal handshake that resists offline password guessing.
SAMLSecurity Assertion Markup LanguageAn XML standard for passing authentication between an identity provider and a web application (enterprise SSO).
SANSubject alternative nameThe certificate field listing every hostname the certificate is valid for.
SASESecure access service edgeSD-WAN networking plus cloud-delivered security (firewall, web gateway, ZTNA, CASB) as one service.
SCADASupervisory control and data acquisitionSystems that monitor and control industrial processes such as power, water, and manufacturing.
SCAPSecurity Content Automation ProtocolStandard formats that let tools check systems against security benchmarks automatically.
SD-WANSoftware-defined wide area networkSteers traffic across several cheap links (broadband, LTE, MPLS) by policy from a central controller.
SDLCSoftware development life cycleThe phases of building software: plan, design, code, test, deploy, maintain.
SDNSoftware-defined networkingSeparates the control plane (decisions) from the data plane (forwarding) and centralizes control.
SFTPSSH File Transfer ProtocolFile transfer inside an SSH session, TCP 22.
SHASecure Hash AlgorithmThe family of hash functions: SHA-1 (deprecated), SHA-2 (SHA-256, the standard), SHA-3.
SHA-1Secure Hash Algorithm 1A 160-bit hash, deprecated because collisions have been found.
SHA-2Secure Hash Algorithm 2The current hash family, including SHA-256 and SHA-512.
SHA-256Secure Hash Algorithm 256-bitThe standard hash today: a 256-bit fingerprint of any input.
SHA-3Secure Hash Algorithm 3A newer hash standard with a different internal design from SHA-2.
SIEMSecurity information and event managementCollects logs from everything, correlates them, and raises alerts.
SIPSession Initiation ProtocolSets up and tears down voice and video calls; port 5060, or 5061 with TLS.
SLAService level agreementThe contract stating measurable service commitments, such as 99.9% uptime.
SLESingle loss expectancyThe cost of one occurrence of a risk: asset value times exposure factor.
SMBServer Message BlockWindows file and printer sharing on TCP 445.
SMSShort Message ServiceText messages; used for one-time codes and also a phishing channel (smishing).
SMTPSimple Mail Transfer ProtocolSends email between servers on TCP 25; clients submit on 587 with TLS.
SMTPSSMTP SecureSMTP with TLS, port 465 (implicit) or 587 with STARTTLS.
SNMPSimple Network Management ProtocolPolls and receives alerts from network devices (UDP 161 polls, 162 traps).
SOWStatement of workDefines one specific piece of work: deliverables, timeline, and price.
SPFSender Policy FrameworkA DNS TXT record listing which servers may send mail for a domain.
SQLStructured Query LanguageThe language used to query databases; also the name of the servers on TCP 1433 (Microsoft) and 3306 (MySQL).
SRTPSecure Real-time Transport ProtocolEncrypted RTP for voice and video.
SSHSecure ShellEncrypted remote command-line access and file transfer on TCP 22; replaces Telnet and FTP.
SSIDService set identifierThe Wi-Fi network name that access points broadcast and clients join.
SSLSecure Sockets LayerThe predecessor of TLS; every version is deprecated.
SSOSingle sign-onLog in once and reach many systems without signing in again.
SSRFServer-side request forgeryMakes the web server itself fetch a URL the attacker supplies, often reaching internal systems.
SY0-701CompTIA Security+ exam SY0-701The current version of the Security+ certification exam.
TACACS+Terminal Access Controller Access-Control System PlusCisco's AAA protocol for device administration on TCP 49; encrypts the whole payload and separates authentication from authorization.
TCPTransmission Control ProtocolReliable, ordered, connection-based transport: three-way handshake, acknowledgments, retransmission.
TFTPTrivial File Transfer ProtocolBare-bones UDP 69 file transfer with no login, used for firmware and config files.
TKIPTemporal Key Integrity ProtocolWPA's per-packet keying scheme; deprecated.
TLSTransport Layer SecurityThe encryption layer under HTTPS and most secure protocols; use 1.2 or 1.3.
TOCTime of checkThe moment a program verifies a condition; in a race condition, before it acts on it.
TOUTime of useThe moment a program acts on a condition it checked earlier.
TPMTrusted Platform ModuleA security chip on the motherboard that stores keys and measurements; required for BitLocker and Windows 11.
TVTelevisionA display or broadcast receiver; smart TVs are IoT devices.
UBAUser behavior analyticsBaselines what each user normally does and flags deviations.
UEFIUnified Extensible Firmware InterfaceModern firmware that replaces BIOS: GPT disks, Secure Boot, mouse-driven setup.
UPSUninterruptible power supplyA battery unit that keeps equipment running through a power cut and conditions the power.
URLUniform resource locatorA web address such as https://www.example.com/page.
USBUniversal Serial BusThe standard port for peripherals, storage, and charging.
UTMUnified threat managementOne appliance bundling firewall, IDS/IPS, antivirus, content filtering, and VPN.
VLANVirtual local area networkA logical LAN on a switch: ports in different VLANs are separate broadcast domains.
VMVirtual machineA complete computer running as software on a hypervisor.
VPNVirtual private networkAn encrypted tunnel across an untrusted network such as the internet.
WAFWeb application firewallA firewall that understands HTTP and blocks attacks on web applications such as SQL injection and XSS.
WANWide area networkConnects LANs across cities or countries, usually over links leased from a provider.
WEPWired Equivalent PrivacyThe original Wi-Fi encryption, broken in minutes; never use it.
Wi-FiWireless fidelityThe trade name for IEEE 802.11 wireless networking.
WOWork orderA short authorization for one specific job.
WPAWi-Fi Protected AccessThe interim fix for WEP that used TKIP; deprecated.
WPA2Wi-Fi Protected Access 2Wi-Fi security using AES with CCMP; still common and acceptable.
WPA3Wi-Fi Protected Access 3The current Wi-Fi security standard: SAE in Personal mode, stronger encryption, protected management frames.
XDRExtended detection and responseEDR extended across endpoints, network, cloud, and email into one correlated view.
XMLExtensible Markup LanguageA text format for structured data, used by SAML, SOAP, and many configuration files.
XSSCross-site scriptingAn attacker's script runs in other users' browsers because a site echoes untrusted input.