ZOLL X: troubleshooting and error codes
The ServiceForge knowledge base holds 2 documented symptoms for the ZOLL X, with 2 ranked causes, 0 diagnostic checks with test points and expected values, and 78 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
Calibration: EtCO2
Annual calibration of end-tidal CO2 monitoring using 5% CO2 calibration gas to ensure accurate readings
Ranked causes
- 1. EtCO2 sensor requires annual calibration per maintenance protocol (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: NIBP
Annual calibration check of non-invasive blood pressure module to verify accuracy of systolic, diastolic and mean pressure readings
Ranked causes
- 1. NIBP module requires annual calibration check per maintenance protocol (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Error codes
| Code | Meaning | Trigger | Severity |
|---|---|---|---|
ALARM SILENCE SHORT | Alarm Silence/Reset key is stuck. | Key stuck in pressed position | warning |
BLUETOOTH PHONE UNAVAILABLE | Unable to establish Wide Area Network connection; no Bluetooth phones detected. | Device cannot detect paired Bluetooth phones | warning |
CELLULAR CONNECT FAILURE | Unable to establish Wide Area Network connection via cellular. | Cellular modem or Bluetooth phone connection attempt failed | warning |
CHECK COMM CONFIGURATION | Configuration error prevented successful communication. | Communication setup contains invalid parameters | warning |
CO2 BAROMETRIC OUT OF RANGE | Altitude is too high for CO2 module. | Device altitude exceeds module operating range | error |
CO2 CAL FAILURE | CO2 module calibration failed. | Calibration procedure unsuccessful | error |
CO2 CAL REMINDER | CO2 module calibration reminder. | Calibration due soon | info |
CO2 CAL REQUIRED | CO2 module calibration is due. | Calibration interval expired | warning |
CO2 CHECK FLOW | CO2 module exhaust port is blocked. | Pressure sensing indicates blocked exhaust | error |
CO2 COM ERROR CODE | Communication failure with CO2 module. | Data transmission error detected | error |
CO2 DEVICE FAILURE | CO2 module malfunction or device failure. | Module self-test or hardware detection failure | error |
CO2 GAS INPUT OCCLUSION | CO2 inlet is blocked. | Inlet pressure or flow sensing indicates blockage | error |
CO2 MAINTENANCE REMINDER | Periodic CO2 module maintenance reminder. | Maintenance interval approaching | info |
CO2 MAINTENANCE REQUIRED | Periodic CO2 module maintenance is due. | Maintenance interval expired | warning |
CO2 NO FILTERLINE | No FilterLine is detected by CO2 module. | Module cannot detect FilterLine connection | error |
DEFIB CAP LEAKAGE | Defibrillator capacitor bank cannot hold a charge. | Capacitor charge decay detected during self-test | critical |
DEFIB CHARGE ERROR | Over voltage was detected during defibrillator charging. | Charging voltage exceeded safe limits | critical |
DEFIB CHARGE TIMEOUT FAIL | Battery did not produce enough current to charge capacitor. | Capacitor failed to charge within timeout period | critical |
DEFIB DEVICE FAILURE | Defibrillator device failure detected. | Self-test energy charge, discharge, or delivery failed | critical |
DEFIB DISCHARGE TEMP | Device is in hot environment or discharge circuit always on. | Temperature threshold exceeded during discharge | error |
DEFIB FATAL CHARGE ERROR | Fatal defibrillator charging error. | Charging operation failed catastrophically | critical |
DEFIB FIRE FAILURE | High or low impedance detected during defibrillator discharge. | Pad impedance out of safe range during therapy delivery | critical |
DEFIB LOW BATTERY | Battery is too low to charge defibrillator. | Battery voltage below defibrillator charging threshold | error |
DEFIB NO ENERGY DELIVERED | High impedance; no defibrillator energy was delivered. | No energy detected at output during therapy | critical |
DEFIB PACER DEVICE FAILURE | Defibrillator/pacer board failure detected. | Board error, self-test or communication failure | critical |
DEFIB PHASE FAILURE | Phase I or phase II defibrillator waveform dropout. | Waveform generation interrupted during discharge | critical |
DEFIB USING DEFAULT CALIBRATION | Defibrillator calibration data lost; using default values. | Stored calibration data corrupted or missing | error |
ECG DEVICE FAILURE | ECG hardware issue detected. | ECG software detected problem with ECG data | error |
FP DEFIB CHARGE SHORT | Defibrillator charge keys are stuck on front panel. | Key stuck in pressed position | warning |
FP DEFIB ENERGY DOWN SHORT | Defib energy Select Down (Decrease) key is stuck on front panel. | Key stuck in pressed position | warning |
FP DEFIB ENERGY UP SHORT | Defib energy Select Up (Increase) key is stuck on front panel. | Key stuck in pressed position | warning |
FP DEFIB FIRE SHORT | Front panel key or button is stuck. | Key or button stuck in pressed position | warning |
HW SHUTDOWN | Voltage threshold exceeded minimum working threshold; device shutting down. | Battery voltage dropped below minimum threshold | critical |
IBP DEVICE FAILURE | IBP hardware issue detected. | IBP software detected problem with IBP data | error |
IBP PROBE1/PROBE2/PROBE3 CIRCUIT FAILURE | Unsupported probe inserted or circuit problem detected. | Probe connection or circuit failure detected | error |
IBP PROBE1/PROBE2/PROBE3 SHORTED | Invasive Blood Pressure probe is shorted. | A/D converter value indicates probe short circuit | error |
NAMESERVICE FAILURE | Reports server hostname could not be resolved via DNS. | DNS lookup failed for server hostname | warning |
NAV PAD DOWN SHORT | Down/Counterclockwise Navigation key is stuck. | Key stuck in pressed position | warning |
NAV PAD SELECT SHORT | Select Navigation key is stuck. | Key stuck in pressed position | warning |
NAV PAD UP SHORT | Up/Clockwise Navigation key is stuck. | Key stuck in pressed position | warning |
NIBP AIR LEAK | Major air leak detected or target pressure not reached. | Pressure fails to reach target during inflation | error |
NIBP ARTIFACT | Unable to determine blood pressure due to artifact. | Signal quality insufficient for measurement | warning |
NIBP COMMUNICATION FAILURE | Communication failure with NIBP module. | Data transmission error with NIBP module | error |
NIBP EQUIPMENT CHECK | Device is unable to obtain a blood pressure reading. | NIBP measurement failed | warning |
NIBP KINKED HOSE | Cuff inflation was too rapid; tubing may be kinked or obstructed. | Inflation rate exceeds expected parameters | warning |
NIBP LOW VOLTAGE | Insufficient voltage supplied to NIBP module. | Module voltage below operating threshold | error |
NIBP MAX PRESSURE EXCEEDED | NIBP pressure limit exceeded. | Measured pressure exceeds safe maximum | error |
NIBP MONITORING FAILURE | NIBP module failure or transducer misalignment detected. | Module failure reported or measurement fault detected | error |
NIBP NEONATAL DETECTED | Device thinks neonate cuff is connected; tubing may be damaged. | Module detected neonate cuff impedance signature | warning |
NIBP TEMP OUT OF RANGE | NIBP module temperature is out of specified operating range. | Module temperature exceeds limits | warning |
NIBP WEAK PULSE | Too few pulses detected during blood pressure reading attempt. | Pulse signal below threshold during measurement | warning |
PACER CURRENT FAULT | Lack of pacer output current. | Pacer current output below threshold | critical |
PACER DEVICE FAILURE | Generation of pacer pulse failed. | Pacer pulse generation unsuccessful | critical |
PRINTER OFFLINE | Printer module is off-line. | Printer module not responding or not powered | warning |
PRINTER OUT OF PAPER | Printer out of paper or paper sensor failure. | No paper detected or paper sensor malfunction | warning |
PRINTER PLATEN OPEN | Printer platen door is open or micro switch failure. | Printer door open or micro switch malfunction detected | warning |
PS DEFIB CHARGE SHORT | Paddle set defibrillator charge keys are stuck. | Key stuck in pressed position | warning |
PS DEFIB ENERGY DOWN | Paddle set energy down keys are stuck. | Key stuck in pressed position | warning |
PS DEFIB ENERGY DOWN SHORT | Paddle set energy down select button is stuck. | Button stuck in pressed position | warning |
PS DEFIB ENERGY UP | Paddle set energy up keys are stuck. | Key stuck in pressed position | warning |
PS DEFIB FIRE SHORT | Paddle set fire keys are stuck. | Key stuck in pressed position | warning |
PS DEFIB RECORDER SHORT | Paddle set recorder keys are stuck. | Key stuck in pressed position | warning |
QUICK ACCESS SW 1 TO SW 7 SHORT | One of the quick access keys (1-7) is stuck. | Key stuck in pressed position | warning |
SCREEN CYCLE SHORT | Display/home key is stuck. | Key stuck in pressed position | warning |
SERVER AUTHENTICATION FAILED | Reports server rejected connection request from device. | Server authentication validation failed | warning |
SERVER UNREACHABLE | WAN connection established but reports server unreachable or connection lost. | Server connection failed despite WAN availability | warning |
SERVICE ERROR <CODE> | Error occurred while communicating with remote server. | Server returned error during communication | error |
SNAPSHOT SHORT | Snapshot key is stuck. | Key stuck in pressed position | warning |
SPO2 COM ERROR CODE | SpO2 module communication error. | Data transmission failure with SpO2 module | error |
SPO2 DEVICE FAILURE | SpO2 communication failure or device malfunction. | Module not responding or self-test failed | error |
SPO2 SENSOR FAILURE | SpO2 sensor defective or error detected. | Sensor self-test or signal validation failed | error |
SPO2 UNKNOWN RECOVERY NUM | SpO2 sensor recovery error. | Sensor recovery procedure failed | error |
SW SHUTDOWN WARNING | Battery has reached software shutdown capacity threshold. | Battery voltage dropped to shutdown threshold | critical |
TEMP1 OR TEMP2 CIRCUIT FAILURE | Temperature probe circuit failure; A/D converter out of range. | A/D converter reading exceeds valid range | error |
TEMP DEVICE FAILURE | Temperature hardware issue detected. | Temperature software detected problem with temperature data | error |
TEMP PROBE1 OR PROBE2 SHORTED | Temperature probe is shorted. | A/D converter value indicates probe short circuit | error |
TRANSMISSION FAILED | Communication operation failed; persists until new operation started. | Wireless transmission attempt failed | warning |
WAN CONNECTION UNAVAILABLE | Unable to establish Wide Area Network connection. | WAN connection attempt failed | warning |
Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI