Xerox Phaser 8200: troubleshooting and error codes
The ServiceForge knowledge base holds 151 documented symptoms for the Xerox Phaser 8200, with 341 ranked causes, 227 diagnostic checks with test points and expected values, and 218 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
Incomplete image transfer to paper
Part of the image remains on the drum instead of fully transferring to paper, usually appearing on chase page or next print
Ranked causes
- 1. Insufficient or non-uniform drum oiling (common)
- 2. Wiper blade in drum maintenance drawer damaged (common)
- 3. Improper media selection (occasional)
- 4. Drum maintenance cam roller or electric clutch malfunction (occasional)
- 5. Drum temperature too high (occasional)
- 6. Paper preheater temperature incorrect (occasional)
- 7. Printhead defective (rare)
Inspect media quality and weight
- Test point
- Paper stock
- Expected
- Smooth paper of appropriate weight
6 more checks with pass and fail actions, 7 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Paper path timing out of range
Paper Path Timing tests (ID #17 and #4) report abnormal sensor-to-sensor timing indicating feeding or skew issues
Ranked causes
- 1. Paper not being picked reliably (common)
- 2. Paper feeding not smooth through trays (common)
- 3. Pick roller contaminated or worn (occasional)
- 4. Excessive paper skew or damage (occasional)
- 5. Front door deskew fingers damaged (occasional)
- 6. Exit rollers slipping or exit flag worn (occasional)
- 7. Transfix roller dirty or improperly oiled (occasional)
Measure timing from Tray 3 pick motor to tray 3 pick flag (ID#17 R#0)
- Test point
- Tray 3 pick motor, tray 3 pick flag
- Expected
- > 850 ms, greater than
6 more checks with pass and fail actions, 7 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Uneven cyan fill
Non-uniform fill throughout the print with possible wrinkling or paper deformity
Ranked causes
- 1. Weak jets (unknown)
- 2. Uneven drum heating (unknown)
- 3. Wrinkling from print media (unknown)
- 4. Drum maintenance tray fouled (unknown)
- 5. Drum-temperature sensor debris or misalignment (unknown)
- 6. Incorrect transfix pressure (unknown)
- 7. Drum/transfix assembly failure (rare)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Uneven magenta fill
Non-uniform fill throughout the print with possible wrinkling or paper deformity
Ranked causes
- 1. Weak jets (unknown)
- 2. Uneven drum heating (unknown)
- 3. Wrinkling from print media (unknown)
- 4. Drum maintenance tray fouled (unknown)
- 5. Drum-temperature sensor debris or misalignment (unknown)
- 6. Incorrect transfix pressure (unknown)
- 7. Drum/transfix assembly failure (rare)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Weak or missing jets in print output
Service Test 2 shows weak or missing jets during print; observable as gaps or thin lines in color output
Ranked causes
- 1. Contaminated wiper blade (common)
- 2. Debris in paper path scraping ink from drum (common)
- 3. Inadequate cleaning cycles (occasional)
- 4. Cap/Wipe/Purge (C/W/P) out of alignment (occasional)
- 5. Contaminated C/W/P with wax streaks (occasional)
- 6. C/W/P wiper gasket separation or pitting (occasional)
- 7. Defective printhead (occasional)
Print Service Test 2 and observe for weak or missing jets
- Test point
- printer output
- Expected
- All jets firing evenly with full color intensity
8 more checks with pass and fail actions, 7 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Black solid fill uneven or wrinkled
Print shows non-uniform fill across the page, wrinkling, or paper deformity in black solid fill test print
Ranked causes
- 1. Weak jets or uneven drum heating (common)
- 2. Drum maintenance tray worn, causing streaking (common)
- 3. Paper type incompatible (occasional)
- 4. Drum temperature sensor debris or misalignment (occasional)
- 5. Transfix pressure incorrect (occasional)
- 6. Drum/transfix assembly failure (rare)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Yellow Solid Fill
Print shows non-uniform fills with possible wrinkling or paper deformity; should show even, uniform fills throughout
Ranked causes
- 1. Weak jets or uneven drum heating (common)
- 2. Wrinkling from print media incompatibility (occasional)
- 3. Streaking from worn drum maintenance tray (occasional)
- 4. Drum temperature sensor debris or improper contact (occasional)
- 5. Incorrect transfix pressure (occasional)
- 6. Defective drum or transfix assembly (rare)
Visual inspection of print
- Test point
- Yellow solid fill print
- Expected
- Even, uniform fills throughout with no wrinkling or paper deformity
4 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Red solid fill uneven or wrinkled
Print shows non-uniform fill across the page, wrinkling, or paper deformity in red solid fill test print
Ranked causes
- 1. Weak jets or uneven drum heating (common)
- 2. Drum maintenance tray worn, causing streaking (common)
- 3. Paper type incompatible (occasional)
- 4. Drum temperature sensor debris or misalignment (occasional)
- 5. Transfix pressure incorrect (occasional)
- 6. Drum/transfix assembly failure (rare)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Wrinkling on print
Print damage usually in corners with solid fills, paper appears wrinkled or creased
Ranked causes
- 1. Media moisture absorption in high-humidity environment (common)
- 2. Improper media weight or type (common)
- 3. Deskew fingers damaged or missing (occasional)
- 4. Maintenance drawer wiper blade damaged (occasional)
- 5. Transfix roller spring pressure incorrect (occasional)
- 6. Drum or transfix assembly defective (rare)
Inspect paper for moisture damage
- Test point
- Media stock
- Expected
- Paper not warped or curled
6 more checks with pass and fail actions, 6 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Blue solid fill uneven or wrinkled
Print shows non-uniform fill with wrinkling or paper deformity
Ranked causes
- 1. Weak jets (common)
- 2. Uneven drum heating (common)
- 3. Drum temperature sensor debris or poor contact (occasional)
- 4. Incorrect transfix pressure (occasional)
- 5. Drum/transfix assembly defective (rare)
Inspect print for uniform fill and absence of wrinkling
- Test point
- Blue solid fill test print
- Expected
- Even, uniform fills throughout print with no wrinkling or paper deformity
4 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Device fault hang
Printer displays device fault code and hangs during operation
Ranked causes
- 1. Fault 5,001.41 - mechanical or power control board (common)
- 2. Fault 7,002.44 - mechanical or power control board (common)
- 3. Fault 7,004.46 - mechanical/I/O Right/power board (common)
- 4. Fault 8,001.44 - mechanical/I/O Right/power board (common)
- 5. Faults 9,005-9,008 (840) or 9,005/9,069/9,037/9,101 (850) (occasional)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Display on/off with LED flash
Display flickers on and off, LED flashing (possible continuous reboot)
Ranked causes
- 1. Power supply issue (common)
- 2. Memory DIMM connection problem (common)
- 3. NVRAM corrupt (occasional)
- 4. Code DIMM corrupt or connection problem (occasional)
- 5. Boot ROM corrupt or connection problem (occasional)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Green solid fill uneven or wrinkled
Print shows non-uniform fill with wrinkling or paper deformity
Ranked causes
- 1. Weak jets (common)
- 2. Uneven drum heating (common)
- 3. Drum temperature sensor debris or poor contact (occasional)
- 4. Incorrect transfix pressure (occasional)
- 5. Drum/transfix assembly defective (rare)
Inspect print for uniform fill and absence of wrinkling
- Test point
- Green solid fill test print
- Expected
- Even, uniform fills throughout print with no wrinkling or paper deformity
4 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Low purge volume or low R2 vacuum reading
Purge volume is low or R2 is less than 3000, indicating leak in vacuum system or inadequate peak vacuum
Ranked causes
- 1. Leak in vacuum system (occasional)
- 2. Inadequate peak vacuum (occasional)
- 3. Misaligned C/W/P belt or motion problem (occasional)
- 4. Damaged C/W/P gasket (occasional)
- 5. Defective vacuum module (occasional)
Verify purge volume and R2 reading from Cap Vacuum test
- Test point
- maintenance tray, diagnostics menu
- Expected
- normal purge volume, R2 between 3000-8000 unspecified, 3000-8000
2 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Poor ink adhesion or poor image durability
Ink does not adhere properly to media, image durability compromised
Ranked causes
- 1. Incorrect media tray setting for transparencies (common)
- 2. Paper preheater temperature incorrect (common)
- 3. Drum temperature too cold (common)
- 4. Inappropriate transparency film type (occasional)
- 5. Transfix roller spring pressure incorrect (occasional)
Verify media tray setting for transparency media
- Test point
- System configuration
- Expected
- Media tray set to 'Transparency'
4 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Printhead error codes detected on display
Printer displays error code indicating printhead problem at startup or during operation
Ranked causes
- 1. Error code 13,035.47 in fault history (rare)
- 2. Open printhead thermostat (rare)
- 3. Error 13,004.43 or 13,020.41 (HTD calibration drift) (occasional)
- 4. Error 13,001.40, 13,002.41, 13017.47, or 13018.48 (ribbon cable issue) (occasional)
- 5. Error 4002.41 or 4006.45 (power control issue) (occasional)
Check error code in fault history for 13,035.47
- Test point
- fault history display
- Expected
- Error 13,035.47 not present or present
2 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Tektronix logo, PE LED heartbeat
Tektronix logo displayed, front panel error light off, rear PE LED showing heartbeat pattern
Ranked causes
- 1. External component or connection (common)
- 2. NVRAM corrupt (occasional)
- 3. Internal component failure (occasional)
- 4. Code DIMM connection problem (occasional)
- 5. Memory DIMM connection problem (occasional)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Tektronix logo, ready light off, PE LED static
Tektronix logo on display, front panel ready light off, rear PE LED static
Ranked causes
- 1. Code DIMM connection problem (common)
- 2. Memory DIMM connection problem (common)
- 3. Failed code ROM DIMM (occasional)
- 4. Failed memory DIMM (occasional)
- 5. Failed main board (occasional)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Y-Axis Geometry test abnormal vibration caution
Diagnostic test measures amplitude and frequency of vibration peaks in y-axis system. Identifies up to 15 peaks. Abnormal results indicate belt, pulley, drum, or motor issues.
Ranked causes
- 1. High vibration at 4.9 Hz (>2500 @ 4.9 +/- 0.5) (occasional)
- 2. High vibration at 6.2 Hz (>2300 @ 6.2 +/- 0.6) (occasional)
- 3. High vibration at 25.4 Hz (>3700 @ 25.4 +/- 2.5) (occasional)
- 4. High vibration at 87.6 Hz (>800 @ 87.6 +/- 8.8) (occasional)
- 5. High vibration at any frequency >15 Hz (>1000) (occasional)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Blank display with front panel lights on
Front panel lights are on but display blank; rear LEDs static
Ranked causes
- 1. Main board not seated correctly (common)
- 2. Code DIMM not seated correctly (common)
- 3. Possible bad upgrade (occasional)
- 4. ESD damage to main board (occasional)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Blank display with rear LED flashing
Front panel lights on, display blank, rear LED flashing (SDRAM error codes may appear)
Ranked causes
- 1. Memory DIMM not seated correctly (common)
- 2. Code DIMM connection problem (common)
- 3. Unsupported or defective memory DIMM (occasional)
- 4. ESD damage to main board (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cap Axis Geometry test abnormal results caution
Diagnostic test measures alignment of Cap/Wipe/Purge assembly via belt hysteresis, motor current, and cap tilt. Results outside range indicate misalignment or tension issues.
Ranked causes
- 1. Right belt hysteresis abnormal (result 0: >75 or <20) (occasional)
- 2. Process Motor no load current high (result 1: >61) (occasional)
- 3. Left belt hysteresis abnormal (result 2: >120 or <50) (occasional)
- 4. Cap tilt abnormal (result 3: >160 or <40) (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cap Vacuum test abnormal results caution
Diagnostic test measures vacuum decay time via head tilt mechanism. Results outside range indicate vacuum system or mechanical issues.
Ranked causes
- 1. No vacuum pull current abnormal (result 0: >200 or <20) (occasional)
- 2. Slack take-up position abnormal (result 1: >1600 or <40) (occasional)
- 3. Vacuum bleed off time too high (result 2: >8000) (occasional)
- 4. Vacuum bleed off time too low (result 2: <3000) (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cap/Wipe/Purge assembly cannot find home caution
Cap-home sensor does not see sensor flag when expected; assembly fails to home
Ranked causes
- 1. Cap-home sensor faulty (occasional)
- 2. Paper-feed motor not operating (occasional)
- 3. Cap/wipe/purge clutch failing (occasional)
- 4. Assembly jammed or obstructed (occasional)
Check alignment of C/W/P assembly belts
- Test point
- C/W/P assembly belts
- Expected
- Belts properly aligned
3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Diagnostic test termination abnormality caution
Diagnostic test completes with termination status indicating fault, abort, failure, or interruption. Test results displayed with status code 2-6.
Ranked causes
- 1. Test interrupted by front panel button press (occasional)
- 2. Test encountered abort condition (occasional)
- 3. Test did not produce expected results (occasional)
- 4. Print engine declared fault during test (rare)
Observe test termination status code
- Test point
- Front panel display or CentreWare IS diagnostic history
- Expected
- Status value 0-6 indicating termination condition
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Failure during power-up
Printer fails or displays error messages during initial startup before Xerox logo appears
Ranked causes
- 1. RAM DIMM not supported or not installed (common)
- 2. POST error or BIST error during startup (common)
- 3. I/O Right not detected (POST Error 4) (occasional)
- 4. Front panel not detected (POST Error 5) (occasional)
Check for failure message on front panel
- Test point
- Front panel display
- Expected
- No message or check message type
2 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Front panel frozen
Front panel display or controls not responding to input
Ranked causes
- 1. Front panel needs reset (common)
- 2. Code DIMM connection problem (occasional)
- 3. Memory DIMM connection problem (occasional)
- 4. Main board connection problem (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Image never prints from Windows application caution
Printer front panel displays 'Receiving data' message as if data is incoming, but nothing prints to paper or printer returns to Ready mode without producing output.
Ranked causes
- 1. Transmission retry timeout setting too low (common)
- 2. Print-to-file option enabled in print dialog (common)
- 3. PC printer driver or settings misconfiguration (occasional)
- 4. Network connectivity problem between PC and network printer (occasional)
Verify TRANSMISSION RETRY setting in printer driver
- Test point
- Printer driver setup options TRANSMISSION RETRY field
- Expected
- Value set to 850
3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Printhead error code detected
Printer displays error code indicating printhead problem
Ranked causes
- 1. Printhead thermostat open (occasional)
- 2. Power supply failure (occasional)
- 3. Printhead ribbon cable connection issue (occasional)
- 4. Power control board failure (occasional)
Note the error code displayed
- Test point
- printer display or fault history
- Expected
- specific error code number
2 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Printhead unable to tilt
Printhead is unable to move on its tilt axis; process motor stalled after attempting multiple revolutions to disengage head tilt mechanism and X-axis displacement
Ranked causes
- 1. Tilt arm motion obstructed by foreign object (common)
- 2. Tilt arm parked on locking pin (occasional)
- 3. X-axis motor failure or resistance out of spec (occasional)
- 4. Damaged gears or belt tension incorrect (occasional)
Visually inspect tilt arm motion path for obstructions
- Test point
- Tilt arm area
- Expected
- No obstruction present
3 more checks with pass and fail actions, 6 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Uneven or nonuniform solid fills in color output
YMCKRGB solid fill prints show wrinkles, deformity, or uneven color density throughout the print
Ranked causes
- 1. Weak jets or uneven drum heating (common)
- 2. Debris buildup on drum temperature sensor or improper sensor contact (common)
- 3. Incorrect transfix pressure (occasional)
- 4. Drum maintenance drawer not properly seated or dirty (common)
Print YMCKRGB solid fill test in duplex at Standard resolution
- Test point
- Paper output
- Expected
- Even, uniform fills throughout all seven color prints
3 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Uneven solid fill in YMCKRGB prints caution
Solid fill prints show wrinkles, deformity, or non-uniform color fills throughout the print, visible in duplex mode at Standard or Enhanced resolutions
Ranked causes
- 1. Weak jets (common)
- 2. Uneven drum heating (common)
- 3. Incorrect transfix pressure (occasional)
- 4. Worn drum/transfix assembly (rare)
Print YMCKRGB test prints in duplex mode at Standard resolution and inspect for wrinkles and uniformity
- Test point
- YMCKRGB solid fill prints
- Expected
- Even, uniform fills throughout each print, no wrinkles or deformity
3 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Voltages test abnormal readings caution
Diagnostic test measures key power supply voltages. Abnormal readings indicate power supply failure or connection issues.
Ranked causes
- 1. 40V ADC reading abnormal (>30739 or <27039) (occasional)
- 2. Vcc voltage ADC reading abnormal (>32235 or <30662) (occasional)
- 3. 3.3V ADC reading abnormal (>33838 or <30615) (occasional)
- 4. Ground sense ADC reading abnormal (>405 or <201) (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Weak or missing jets
Service Test 2 shows weak or missing ink jets affecting print quality
Ranked causes
- 1. Contaminated maintenance drawer wiper blade (common)
- 2. Debris in paper path scraping ink from drum (occasional)
- 3. Weak jet not recovered by maintenance cycle (common)
- 4. Cap/Wipe/Purge system issue (common)
Clean the maintenance drawer wiper blade
- Test point
- maintenance drawer
- Expected
- clean wiper blade with no contamination
2 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Y-Axis Belt Slip test abnormal results caution
Diagnostic test prints banded image and measures effect on y-axis motion during transfix. Results indicate media weight, belt tension, or image quality issues.
Ranked causes
- 1. Slip index too high (>4.0) (occasional)
- 2. Slip index too low (<1.8) (occasional)
- 3. Peak Y-axis following error high (>72) (occasional)
- 4. Peak Y-axis following error low (<40) (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Black ink-melt heater jam caution
Black ink-melt heater on but ink not dripping; ink stick jam suspected
Ranked causes
- 1. Ink stick jam in black chute (common)
- 2. Ink loader failure (occasional)
- 3. Power supply failure (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: X-axis scale adjustment
Thin parallel pin stripes running length of page, evenly spaced across width, visible on test print; requires menu-based scale adjustment
Ranked causes
- 1. Printhead X-axis motion gain or rate-of-travel incorrect (common)
- 2. NVRAM chip (Phaser 840) or BootROM/Printer ID chip (Phaser 850/860) replaced (occasional)
- 3. X-axis component replaced (occasional)
Allow printer to reach idle Ready to Print state
- Test point
- Printer status display
- Expected
- Printer displays Ready to Print status
5 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Communication problem with network or host
Printer cannot communicate with network or connected computer
Ranked causes
- 1. Ethernet hardware port issue or network configuration problem (occasional)
- 2. Parallel port hardware issue or cable problem (occasional)
- 3. Main board port failure after hardware verification (rare)
Test Ethernet port if connected by Ethernet
- Test point
- Ethernet port and network connection
- Expected
- Web browser accesses CentreWare IS page with printer IP address
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cyan ink-melt heater jam caution
Cyan ink-melt heater on but ink not dripping; ink stick jam suspected
Ranked causes
- 1. Ink stick jam in cyan chute (common)
- 2. Ink loader failure (occasional)
- 3. Power supply failure (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
DM Axis Performance test abnormal results caution
Diagnostic test measures drum maintenance system controllability, sensor distances, clutch timing, wipe/oil cycles, and drag. Results outside normal ranges indicate mechanical issues.
Ranked causes
- 1. Controllability flag failure (result 0) (rare)
- 2. High wipe/oil drag values (results > 19) (occasional)
- 3. Low maintenance drawer lift results (< 9) (occasional)
Run DM Axis Performance test (Test ID# 6)
- Test point
- Controllability flag result
- Expected
- Result not 0
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Drum maintenance home flag detection failure caution
Maintenance blade position sensor failed to detect drum-maintenance home flag transitions
Ranked causes
- 1. Compound gear not rotating (common)
- 2. Drum maintenance cam or bushings damaged (occasional)
- 3. Faulty I/O board or clutch (occasional)
Observe drum-maintenance home flag motion while turning on printer
- Test point
- Drum-maintenance home flag
- Expected
- Flag rotates during power-on sequence
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
False media jam message
Printer displays media jam error without actual jam present
Ranked causes
- 1. Lower Tray paper pick flag stuck (common)
- 2. Lower Tray Assembly fuse blown (occasional)
- 3. Damaged Lower Tray connector (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Magenta ink-melt heater jam caution
Magenta ink-melt heater on but ink not dripping; ink stick jam suspected
Ranked causes
- 1. Ink stick jam in magenta chute (common)
- 2. Ink loader failure (occasional)
- 3. Power supply failure (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Media jam in Lower Feeder 2
Paper does not feed from lower feeder 2, sensor events or timeouts detected
Ranked causes
- 1. Tray pulled out during printing (common)
- 2. Static charge on rear tray sensor (occasional)
- 3. Lower feeder failure (occasional)
Verify tray position
- Test point
- Lower Feeder 2 tray
- Expected
- Tray fully inserted
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
No lights or sound during power on
Printer shows no lights or sound when powered on, no fan movement
Ranked causes
- 1. Short in power system (common)
- 2. No wall power (common)
- 3. Power supply failed (common)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Oil streaks on print edge
Oil stains appear on the edge of the print
Ranked causes
- 1. Drum maintenance cam roller or electric clutch not operating correctly (common)
- 2. Wiper blade in drum maintenance drawer damaged (common)
- 3. Drum maintenance actuators not operating correctly (occasional)
Test drum maintenance cam roller and electric clutch operation
- Test point
- Drum maintenance system
- Expected
- Components operating correctly
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Oil streaks on top of print
Oil marks appear on top surface of printed output
Ranked causes
- 1. Stripper fingers or rapid release guide soiled (common)
- 2. Maintenance drawer blade soiled or damaged (common)
- 3. Ink residue on drum (common)
Clean stripper fingers and rapid release guide
- Test point
- Print path components
- Expected
- Components clean and free of oil residue
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Paper path status diagnostic abnormal
Paper Path Status test (Test ID #3) identifies sensor state abnormalities that would prevent page printing
Ranked causes
- 1. Media present in paper path (common)
- 2. Door or cover open (common)
- 3. Missing or improperly installed tray (occasional)
Verify duplex media sensor detects paper
- Test point
- Duplex sensor
- Expected
- 1 = No media at duplex sensor
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Power supply does not output DC voltages high voltage
Fuses functional but no DC voltages measured from power supply output
Ranked causes
- 1. Shorted motor or solenoid driver (common)
- 2. Power control board has shorted driver (occasional)
- 3. Defective motor or solenoid (occasional)
Disconnect +40 DC loopback connector and attach service load (Phaser 840/850 only)
- Test point
- J250 connector
- Expected
- Rear panel LEDs illuminate
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Printer does not initialize
Printer does not begin initializing when powered on; Power light may not be on
Ranked causes
- 1. AC input voltage out of specification (common)
- 2. Power supply fuse F1 open (common)
- 3. Power supply defective (occasional)
Measure AC input voltage
- Test point
- Power supply input
- Expected
- 87 to 128 VAC (115 VAC nominal) or 174 to 250 VAC (220 VAC nominal), 87–128 VAC or 174–250 VAC
- Tools
- DMM
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Printer intermittently hangs or stops responding
Printer becomes unresponsive at random intervals during operation
Ranked causes
- 1. Normal operation taking extended time (common)
- 2. Corrupt data from network or host causing crash (occasional)
- 3. Main board component failure or static damage (occasional)
Determine if front panel responds during apparent hang
- Test point
- Front panel buttons and cover sensors
- Expected
- Panel responds to input
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Printer shuts down or reboots unexpectedly
Printer spontaneously powers off or restarts without user action
Ranked causes
- 1. Power source problem or overcurrent condition (common)
- 2. Power supply failure with slow restart (occasional)
- 3. Fault condition triggering automatic reboot (common)
Observe power-on behavior after shutdown
- Test point
- Power switch and rear panel LEDs
- Expected
- Power-up begins within 2 seconds or after 6 seconds
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Yellow ink-melt heater jam caution
Yellow ink-melt heater on but ink not dripping; ink stick jam suspected
Ranked causes
- 1. Ink stick jam in yellow chute (common)
- 2. Ink loader failure (occasional)
- 3. Power supply failure (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Black stripe on every print
2-inch wide black stripe from top to bottom on every print, all 4 colors
Ranked causes
- 1. Damaged printhead data cable (common)
- 2. Failed main board (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Transfix roller pressure spring adjustment patient safety
Print wrinkles on left or right side in duplex mode due to unbalanced transfix roller pressure; requires synchronized set screw adjustment
Ranked causes
- 1. Transfix roller pressure unbalanced between left and right sides (common)
- 2. Wrinkling on both left and right sides indicates drum/transfix assembly failure (occasional)
Print YMCKRGB test in duplex mode
- Test point
- Printed test page output
- Expected
- YMCKRGB test printed without wrinkles on both sides
8 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Compound gear sensor not detecting transitions caution
Compound gear sensor reports no transitions when gear should be turning
Ranked causes
- 1. Sensor physically broken (occasional)
- 2. Sensor not plugged in (common)
Run diagnostics to verify compound gear sensor operation
- Test point
- Compound gear sensor
- Expected
- Sensor detects transitions when gear turns
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
High R2 vacuum reading
R2 reading greater than 8000 from Cap Vacuum test, indicating problem with air solenoid or clogged tubing
Ranked causes
- 1. Defective air solenoid (occasional)
- 2. Clogged vacuum tubing (occasional)
Verify R2 reading from Cap Vacuum test
- Test point
- diagnostics menu
- Expected
- R2 between 3000-8000 unspecified, 3000-8000
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Intermittent power loss with spurious over-current caution
Printer shuts down then powers up again after 2–6 seconds; fans twitch briefly and LEDs flash.
Ranked causes
- 1. Spurious over-current detection (occasional)
- 2. Power supply auto-ranged to 220 VAC (occasional)
Measure power-up time from power switch to stable operation
- Test point
- Front panel LEDs
- Expected
- Within 2 seconds for normal operation
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Lower tray assembly connection failure caution
Problem detected with lower tray assembly or its installation; connection faulty
Ranked causes
- 1. Damaged LTA connector (occasional)
- 2. Damaged printer-side connection (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Media jam - timeout on pick flag Lower Feeder 2
Media does not move from lower feeder 2 within expected time
Ranked causes
- 1. Leading-edge jam with right corner folded (common)
- 2. Media bias block clamping media in tray (common)
Verify media loading
- Test point
- Lower Feeder 2 tray
- Expected
- Tray properly loaded with adequate media
7 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
More symptoms
- No response to power switch
- Printhead-to-drum gap incorrect
- Process motor stall during operation
- Process Motor test abnormal results
- Repeating print defects on print
- Transfix Load test abnormal results
- Wrinkled paper in duplex solid fill prints
- X-axis motor not moving
- Y-Axis Encoder test abnormal results
- Abnormal purge vacuum readings
- Bad message ID in DMC event request
- Black ink-level sensor malfunction
- C/W/P belt misalignment
- C/W/P wiper gasket separation or pitting
- Calibration: Cap/wipe/purge assembly belt alignment (timing)
- Calibration: Drum position encoder gap setting
- Calibration: Drum position encoder gap setting (alternate model)
- Calibration: Printhead-to-drum gap
- Calibration: Printhead-to-drum gap adjustment
- Calibration: Transfix roller pressure spring adjustment after continued wrinkling
- Cap Axis Drive test abnormal results
- Cap task unexpected message during homing
- Cap/wipe/purge sensor actuated too soon
- Color mixing between rows
- Cyan ink-level sensor malfunction
- Diagnostic test initialization failure
- DMC event parameter block not found in linked list
- DMC event parameter block not prepped
- DMC motion segment programmed too late
- DMC motion segment too short
- DMC timer event missed
- DMC timer parameter block not found
- Drum heater not heating or heating slowly
- Drum heater running away
- Drum maintenance home sensor actuated too soon
- Drum maintenance home sensor state error
- Drum maintenance unexpected motion detected
- Drum thermistor open circuit
- Drum thermistor short circuit
- Drum thermistor temperature fault
- Electronics fan twitches or rear LEDs blink then stop
- Energy Star mode door open error
- Ethernet port communication verification
- Heater fuse F2 or F3 open
- Ink smears on first side of duplex print
- Ink well sense cable unplugged
- Invalid device state argument to DMC
- LEDs blink then hang in unknown state
- Magenta ink-level sensor malfunction
- Media jam - pick flag stuck in Lower Feeder 2
- No lights or sound on power-up (Phaser 850 specific)
- Non-Xerox ink failure suspected
- Paper path drive current excessive
- Parallel port communication verification
- Power remains on after power switch off
- Power supply failure
- Preheater heater not heating or heating slowly
- Preheater heater running away
- Preheater thermistor ADC converter fault
- Preheater thermistor open circuit
- Preheater thermistor short circuit
- Preheater thermistor temperature fault
- Printer does not power up
- Printer does not print built-in page
- Printer shuts down unexpectedly
- Printhead left jet stack heater not heating or heating slowly
- Printhead left jet stack heater running away
- Printhead left jet stack thermistor open circuit
- Printhead left jet stack thermistor short circuit
- Printhead reservoir ADC converter fault
- Printhead reservoir heater not heating or heating slowly
- Printhead reservoir heater running away
- Printhead reservoir thermistor open circuit
- Printhead reservoir thermistor short circuit
- Printhead right jet stack heater not heating or heating slowly
- Printhead right jet stack heater running away
- Printhead right jet stack thermistor open circuit
- Printhead right jet stack thermistor short circuit
- Process motor DMC status message mismatch
- Process motor task negative delay error
- Process motor task unexpected message error
- Short circuit in power supply system
- Squiggly vertical lines on print
- Stagnant ink discoloration in solid color areas
- Streaking visible in solid fill prints
- Unexpected CAP command in idle state
- Unexpected XA message received
- Use error handler for print failures
- Vacuum pump and solenoid valve function check
- Wax streaks or smudges on printhead faceplate
- Yellow ink-level sensor malfunction
91 more symptoms with ranked causes and checks are in ServiceForge. Connect ServiceForge to your AI
Error codes
| Code | Meaning | Trigger | Severity |
|---|---|---|---|
04,001.40 | PC device fault: failure reading printhead NVRAM data | Printhead NVRAM data cannot be read at boot or during operation | error |
04,002.41 | PC device fault: printhead NVRAM data all zeros | Printhead NVRAM contains all 0x00 values at read | error |
07,001.43 | Lower tray assembly problem; connection failure or installation error | Detected during initialization or operation | error |
07,001.65 | Bad I/O right circuit board detected | Lower tray assembly fault reported | error |
07,002.44 | Process motor stall detected | Process motor fails to complete motion during transfix, drum maintenance, or head tilt | error |
07,003.45 | Compound gear sensor failed to detect transitions | No sensor transitions observed when compound gear should rotate | error |
07,004.46 | Drum maintenance cam home sensor state error; sensor did not actuate as expected | Drum maintenance home sensor behavior incorrect during initialization or operation | error |
07,005.47 | Drum maintenance sensor position error; actuated at unexpected time | Home sensor triggered earlier than expected | error |
07,006.48 | Drum maintenance unexpected motion; sensor actuated when no motion expected | Home sensor actuates during idle or no-motion condition | error |
08,001.44 | Cap/Wipe/Purge assembly cannot find home position; sensor did not see flag | Cap-home sensor fails to detect expected flag position during homing | error |
08,003.46 | Cap-home sensor actuated too soon; assembly obstructed during motion | Home sensor triggers earlier than expected during homing motion | warning |
08,009.65 | Unexpected message during cap/wipe/purge assembly homing; Y-Axis encoder failure | Unexpected ITC message received during CAP assembly initialization or homing | error |
09,009.44 | Ink well sense cable unplugged from printhead | Printhead ink well sense cable detected as disconnected | warning |
10 | EEPROM test failure | First 24 bytes read from EEPROM fails to verify Tektronix Ethernet address | error |
10.01 | EEPROM read failure | POST Printer ID chip test | error |
10.02 | EEPROM write failure | POST Printer ID chip test | error |
10.03 | EEPROM re-read failure | POST Printer ID chip test | error |
10.04 | EEPROM write/read mismatch | POST Printer ID chip verification | error |
11 | Mariner ASIC version verification failure | Mariner ASIC on main board fails version level verification | error |
11,001.60 | DMC timer event missed; health check detected timer event in past | Health check routine detects timer event scheduled for time in past | error |
11,007.66 | DMC event parameter block not prepped before notification request | DMC library receives unprepared parameter block in event request | error |
11,008.67 | Bad message ID in DMC event request; inconsistent state field | DMC event notification request contains invalid state field | error |
11.01 | Ethernet port chip failure | POST Ethernet test | error |
11,011.61 | DMC event parameter block not found in linked list | DMC library unable to locate event parameter block | error |
11.02 | Ethernet port ID error | POST Ethernet chip identification | error |
11,020.61 | DMC timer parameter block not found in linked list | DMC library unable to locate timer parameter block | error |
11,022.63 | Invalid device state argument to dmc_get_device_stat() | DMC function receives invalid ITC message base parameter | error |
11,025.66 | DMC motion segment programmed too late; interrupt service routine missed | DMC ASIC interrupt to program event control hardware occurs too late for next segment | error |
11,029.61 | DMC motion segment too short; less than 750 microseconds | Software attempts to program motion profile with insufficient segment duration | error |
11033.65 | Motion Control Event Missed | Health check routine detects pending hardware motion profile event is in the past | error |
11034.66 | Motion Control Done Timer Too Late | Cannot program motion control profile done event in time | error |
11038.61 | A/D Input Out of Range | MEDUSA ASIC analog to digital calibration detects input out of tolerance | error |
11039.62 | Printhead NVRAM Read Failure | NVRAM read attempt via I2C interface fails | error |
12 | Medusa ASIC version verification failure | Medusa ASIC on main board fails version level verification | error |
12002.62 | ITC Send Message Failure (secondary failure) | Message queue full; unable to place message in destination queue | error |
12.xx | CPU Interrupt test failure or unexpected interrupt request | POST CPU interrupt test | critical |
13 | Super Glue ASIC version verification failure | Super Glue ASIC on main board fails version level verification | error |
13,001.40 | Printhead ribbon cable communication error | Cable connection issue or cable failure | error |
13001.40 | Left Jet Stack Thermistor Open | Thermistor in left jet stack detected as open circuit | error |
13,002.41 | Printhead ribbon cable communication error | Cable connection issue or cable failure | error |
13002.41 | Left Jet Stack Thermistor Short | Thermistor in left jet stack detected as shorted | error |
13003.42 | Left Jet Stack Heater Running Away | Left jet stack heater temperature uncontrolled and rising | critical |
13004.43 | Left Jet Stack Heater Slow | Left jet stack heater not heating or heating too slowly | warning |
13.01 | USB test failure | POST USB test | critical |
13011.66 | Bad TCH Message in Fault State | Unexpected message received by reservoir thermal manager while in device fault state | error |
13,017.47 | Printhead ribbon cable communication error | Cable connection issue or cable failure | error |
13017.47 | Right Jet Stack Thermistor Open | Thermistor in right jet stack detected as open circuit | error |
13,018.48 | Printhead ribbon cable communication error | Cable connection issue or cable failure | error |
13018.48 | Right Jet Stack Thermistor Short | Thermistor in right jet stack detected as shorted | error |
13019.40 | Right Jet Stack Heater Running Away | Right jet stack heater temperature uncontrolled and rising | critical |
13020.41 | Right Jet Stack Heater Slow | Right jet stack heater not heating or heating slowly | warning |
13033.45 | Reservoir Thermistor Open | Thermistor in ink reservoir detected as open circuit | error |
13034.46 | Reservoir Thermistor Short | Thermistor in ink reservoir detected as shorted | error |
13,035.47 | Printhead thermostat failure detected | Thermostat open or abnormal reading | error |
13035.47 | Reservoir Heater Running Away | Reservoir heater temperature uncontrolled and rising | critical |
13036.48 | Reservoir Heater Slow | Reservoir heater not heating or heating slowly | warning |
13037.61 | Reservoir ADC Is Bad | Analog to digital converter for reservoir thermistor appears faulty | error |
14 | CL1284 parallel port controller chip test failure | CL1284 IC on main board fails version level verification | error |
14.xx | Real Time Clock test failures | POST RTC test (soft error) | warning |
15000.40 | Drum Temperature Incorrect | Drum temperature sensed by thermistor is out of specification | warning |
15001.42 | Drum Thermistor Open | Drum thermistor detected as open circuit | error |
15002.43 | Drum Thermistor Short | Drum thermistor detected as shorted | error |
15003.44 | Drum Heater Running Away | Drum heater temperature uncontrolled and rising | critical |
15004.45 | Drum Heater Slow | Drum heater not heating at normal rate | warning |
15.01 | RAM SODIMM in slot 1 failed | POST RAM slot 1 test (soft error) | warning |
15.02 | RAM SODIMM in slot 2 failed | POST RAM slot 2 test (soft error) | warning |
15.03 | RAM SODIMM in slot 1 incompatible | POST RAM slot 1 compatibility test (soft error) | warning |
15.04 | RAM SODIMM in slot 2 incompatible | POST RAM slot 2 compatibility test (soft error) | warning |
16000.40 | Preheater Temperature Incorrect | Preheater temperature sensed by thermistor is out of specification | warning |
16001.43 | Preheater Thermistor Open | Preheater thermistor detected as open circuit | error |
16002.44 | Preheater Thermistor Short | Preheater thermistor detected as shorted | error |
16003.45 | Preheater Heater Running Away | Preheater heater temperature uncontrolled and rising | critical |
16004.46 | Preheater Heater Slow | Preheater not heating or heating slowly | warning |
16005.47 | Preheater Thermistor ADC Bad | Invalid reading reported by preheater thermistor ADC converter | error |
16.01 | Less than 64 MB of RAM detected | POST RAM capacity test (soft error) | warning |
17 | Ethernet chip existence test failure | Ethernet chip on main board not detected or does not respond | error |
17.xx | Unrecognized option card responding | POST option card detection (should never occur) | error |
18.xx | Optional Token Ring card failures | POST option card test (should never occur) | error |
19001.4X | Printhead Calibration Dev Fault 0x01 | Incorrect reading during scales and offset calibration | error |
19002.4X | Printhead Calibration Dev Fault 0x02 | Incorrect reading during printhead data tap determination | error |
19008.63 | Incorrect Printhead Installed | Printhead type does not match software compilation | error |
2 | SDRAM SIMM presence test failed | Power-on self-test detects missing SDRAM modules | error |
20.01 | I/O Left not detected | POST I/O Left detection | error |
2,001.40 | System fault: engine cannot detect presence of right I/O board | Right I/O board not detected at power-up or during operation | error |
20.02 | I/O Left partially responding | POST I/O Left communication test | error |
2,002.40 | System fault: engine cannot detect presence of left I/O board | Left I/O board not detected at power-up or during operation | error |
2,002.61 | System program fault: queue initialization failure during engine firmware boot | sy_creat_queues() function call fails during sy_app_init() execution | error |
2,003.62 | System program fault: unable to start service diagnostic tasks during boot | sy_app_init() fails to start service diagnostics task while booting into diagnostic mode | error |
2.01 | Failure to read chip IDs | POST chip ID test at power-up | critical |
2.02 | Failure testing timer values | POST timer test at power-up | critical |
21.01 | Printhead not responding | POST printhead communication test | critical |
21.02 | Printhead NVRAM not responding | POST printhead NVRAM test | critical |
21.03 | Printhead ink level sensed below range | POST ink level sensor test (soft error) | warning |
21.04 | One color sensed out of range for printhead ink level | POST ink level color range test (soft error) | warning |
21.05 | Printhead reservoir thermistor above range | POST printhead temperature sensor test | error |
21.06 | Left printhead jetstack thermistor out of range | POST left jetstack temperature test | error |
21.07 | Right printhead jetstack thermistor out of range | POST right jetstack temperature test | error |
21.08 | Printhead reservoir thermistor out of range | POST printhead reservoir temperature test | error |
22.01 | Maintenance Kit counter not responding | POST maintenance kit counter test (soft error) | warning |
22.02 | Intermittent response from maintenance kit counter | POST maintenance kit counter test (soft error) | warning |
22024.01 | Printhead Not Parked When Powered Off | Printhead was not in parked position at power down | warning |
22,101.06 | Unexpected lower tray present sensor event in Lower Feeder 2 with media in Lower Feeder 2 | Tray present sensor detects unexpected event while media is present in feeder | warning |
22,102.07 | Sticky pick flag in Lower Feeder 2 with media picked from Lower Feeder 2 | Media does not advance due to restricted pick flag motion | warning |
22,102.18 | Time-out on pick flag of Lower Feeder 2 with media picked from Lower Feeder 2 | Pick flag does not complete motion within timeout period | warning |
22,104.11 | Time-out on pick flag of Lower Feeder 1 with media picked from Lower Feeder 2 | Pick flag motion timeout when picking from Lower Feeder 2 | warning |
22,105.01 | Unexpected standard tray sensor event with media in Lower Feeder 2 | Standard tray sensor detects unexpected event while media in lower feeder | warning |
22,200.06 | Command stop event with media in lower feeder 1 | System stop command issued while media present in feeder 1 | error |
22,306.15 | Time-out of pick flag on main tray with media picked from the main tray | Pick flag does not respond within expected time | error |
22,322.13 | Unknown standard tray event | Unexpected standard tray event | warning |
22,411.01 | Handfeed width A or A4 sensor event | Media not detected at handfeed sensor or wrong size | warning |
22,500.00 | Command stop event with media in front door area | Media detected in front door area during command stop | error |
22,501.01 | Unexpected Lower-tray-present sensor event in Lower Feeder 2 with media in front door area | Lower tray sensor triggered unexpectedly | warning |
22,503.03 | Unexpected Lower-tray-present sensor event in Lower Feeder 1 with media in front door area | Lower tray sensor triggered unexpectedly | warning |
22,505.05 | Unexpected standard-tray-sensor event with media in front door area | Standard tray sensor triggered unexpectedly | warning |
22,506.06 | Unexpected standard tray pick flag event | Pick flag triggered unexpectedly | error |
22,508.08 | Unexpected preheat entry sensor (left side) event | Preheat entry sensor triggered unexpectedly | warning |
22,508.10 | Time-out on preheat entry sensor (left side) | Preheat entry sensor does not trigger within expected time | error |
22,511.02 | Unexpected A/A4 sensor event | A/A4 width sensor triggered unexpectedly | warning |
22,512.14 | Time-out on preheat exit sensor | Preheat exit sensor does not trigger within expected time | error |
22,514.05 | Unexpected Exit Sensor event | Exit sensor triggered unexpectedly | warning |
22,522.04 | Media not exiting completely | Media remains in exit area beyond expected time | error |
22,538.13 | Time-out on preheat exit sensor (duplex) with media in front door area | Preheat exit sensor does not trigger within expected time in duplex mode | error |
22,541.05 | Unexpected A/A4 sensor event | A/A4 width sensor triggered unexpectedly | warning |
22,542.17 | Time-out on preheat exit sensor (duplex). Unexpected duplex sensor event | Preheat exit sensor or duplex sensor timeout in duplex mode | error |
22,548.03 | Duplex long declaration determined from duplex sensor | Duplex sensor detects media longer than expected | warning |
22,600.01 | Command stop event with media in exit cover area | Media detected in exit cover area during command stop | error |
22,601.02 | Unexpected Lower-tray-present-sensor event in Lower Feeder 2 with media in exit door area | Lower tray sensor triggered unexpectedly | warning |
22,603.04 | Unexpected Lower-tray-present-sensor event in Lower Feeder 1 with media in exit door area | Lower tray sensor triggered unexpectedly | warning |
22,605.05 | Unexpected standard-tray-sensor event with media in exit door area | Standard tray sensor triggered unexpectedly | warning |
22,613.05 | Unexpected stripper exit sensor event | Stripper exit sensor triggered unexpectedly | warning |
22,613.16 | Unexpected stripper exit sensor event | Stripper exit sensor triggered unexpectedly | warning |
22,614.06 | Unexpected duplex-sensor event | Duplex sensor triggered unexpectedly | warning |
22,638.14 | Time-out on preheat-entry sensor (duplex) with media in exit cover | Preheat entry sensor does not trigger within expected time in duplex mode | error |
22,644.11 | Time-out on duplex sensor | Duplex sensor does not trigger within expected time | error |
22,700.02 | Command-stop event while transfixing (positioning error at start of drum maintenance or imaging) | Command stop during transfix operation due to positioning error | critical |
22703.05 | Y-axis stall during transfix operation | Motor stall during transfix, typically caused by belt slippage | error |
22705.07 | Y-axis time-out during transfix media movement to exit sensor | Media did not reach exit sensor within timeout period | error |
22706.08 | Y-axis declared page too short using A4 sensor or preheat exit sensor | Media length detected as shorter than expected for smaller size media | error |
22707.00 | Y-axis declared media too long, typically from multipick or stuck A4 sensor | Media length exceeds expected maximum | error |
22721.05 | Y-axis print failure, media did not arrive at preheat exit sensor in time | Media did not reach preheat exit sensor before print completion window | error |
22722.06 | Y-axis timeout during transfix moving media to stripper sensor | Media did not reach stripper sensor within timeout period | error |
22900.04 | Unexpected front door event detected | Front door opened during operation or spurious event | warning |
22901.05 | Unexpected exit cover event detected | Exit cover opened during operation or spurious event | warning |
23003.65 | Head Tweak Read Failed from NVRAM | Read of head tweak value failed; two saved values differ | critical |
23089.61 | NVRAM Programming Fault (0x59), same as 23003.65 | NVRAM head tweak value invalid | critical |
23133.60 | NVRAM Corruption Detected on power-up | Firmware validation check detects corrupted NVRAM variable | error |
3 | SDRAM bank 0 test failed | Power-on self-test detects failure in DRAM bank 0 | error |
31001.4x | Auxiliary Motor Error | Auxiliary motor fault condition | unknown |
31002.4x | Process Motor Stall | Process motor stall detected | unknown |
31003.42 | Preheat Exit Sensor Bad diagnostic action | Sensor reading conflict detected | error |
31003.4x | Preheat Exit Sensor Bad | Sensors around preheater exit indicate media presence/absence contradicting preheat exit sensor reading | error |
31044.60 | Bad Message in mp_sleep_for() function | Media path task received unexpected inter-task communication message during delay period | error |
31049.65 | Program fault during auxiliary tray pick | Media path task received unexpected inter-task communication message during auxiliary tray pick | error |
31058.65 | Bad message during auxiliary tray pick operations | Media path task received unexpected inter-task communication while picking from auxiliary tray | error |
4 | SDRAM bank 1 test failed | Power-on self-test detects failure in DRAM bank 1 | error |
4002.41 | Power control board or printhead ribbon cable failure | Power control circuit malfunction or cable fault | error |
4,003.42 | PC device fault: printhead NVRAM data all ones | Printhead NVRAM contains all 0xFF values at read | error |
4,004.43 | PC device fault: printhead NVRAM checksum failure | Checksum verification of printhead NVRAM data fails | error |
4,006.45 | Power control board or printhead ribbon cable failure | Power control circuit malfunction or cable fault | error |
4,006.67 | PC program fault: undefined message received by processor | Processor receives unrecognized or undefined message | error |
4.01 | I/O Right or front panel not detected | POST I/O testing; front panel not initialized | critical |
4,013.43 | PC device fault: printhead unable to move on tilt axis due to collision | Process motor stalls after attempting to disengage head tilt mechanism through multiple revolutions and X-axis displacement | error |
4,014.44 | PC device fault: calibration failure | Calibration process fails | info |
4,015.45 | PC device fault: printhead adjust timeout | Engine remains in printhead adjust state for over 20 minutes | error |
4,016.46 | PC device fault: printhead NVRAM format number not understood | Printhead format number in NVRAM does not match firmware version expectations | error |
4,016.68 | PC program fault: bad message in main ready loop | pc_ready() receives unexpected or out-of-order message while printer waiting for PostScript command | error |
4,017.47 | PC device fault: ambient temperature below minimum | Ambient temperature drops below 10°C | warning |
4,018.48 | PC device fault: printhead temperature dropped during warm-up | Printhead temperature falls below clean threshold after initial warm-up assessment at power-up | warning |
4,019.40 | PC device fault: 193 DPI calibration failure | Target Volt-Sec Area of Fast Color mode cannot be achieved during calibration | error |
4,020.41 | PC device fault: head and cap in contact at boot | Head/cap contact flag set in NVRAM at power-up | error |
4,021.42 | PC device fault: drum surface dirty at boot | Drum dirty flag set in NVRAM at power-up | warning |
4,023.66 | PC program fault: dangerous process motor motion detected | PC task detects unsafe printer position before sending motor command to print, chase, or move eccentric/dm cam | error |
4,029.63 | PC program fault: head calibrate task spawn failed | Attempt to spawn printhead calibration task fails | error |
4,032.66 | PC program fault: undefined result in process result handler | pc_process_result() receives undefined inter-task communication result message | error |
4,035.60 | PC program fault: bad status message in process status handler | pc_process_status() receives unexpected inter-task communication status message | error |
4,040.65 | PC program fault: re-entrant halt sequence detected | Soft shutdown request made while printer already in halt state | error |
4,046.62 | PC program fault: dangerous process motor motion during shutdown | PC detects unsafe print head position during soft shutdown when sending motor command | error |
4,051.67 | PC program fault: bad command result during drum warm-up | PostScript command returns SERVICE_NEEDED during drum warm-up initialization | error |
4,059.66 | PC program fault: bad command result during drop flush processing | PostScript command returns SERVICE_NEEDED during big drop flush operation | error |
4,064.62 | PC program fault: invalid thermal state in non-volatile memory | Thermal state value in NVRAM not recognized by firmware | error |
4,128.63 | PC program fault: bad command result waiting for fault clear | PostScript command returns SERVICE_NEEDED while waiting for fault state to clear | error |
4,243.61 | PC program fault: printhead invalid set point for print mode | Printhead detected with different set points for different print modes; invalid set point for selected mode | error |
5 | SDRAM bank 2 test failed | Power-on self-test detects failure in DRAM bank 2 | error |
5,001.41 | Y-axis drum-home sensor failure | Drum completes full revolution without drum-home sensor activation | error |
5,002.42 | Y-axis position failure | Drum position does not match expected position | error |
5,005.67 | Y-axis bad inter-task communication in home state | YA task receives YA_CMD_INIT or unrecognized command while in home state | error |
5.01 | Front panel not detected | POST front panel test at power-up | critical |
5,026.61 | Y-axis missed rendezvous message during image printing | YA task fails to receive rendezvous message to sync drum motion to paper path during transfix | error |
6 | SDRAM bank 3 test failed | Power-on self-test detects failure in DRAM bank 3 | error |
6,000.41 | X-axis motor current fault (XA_FAULT_MCURRENT) | X-axis motor control detects coil open/short or motor fuse open | error |
6,001.42 | X-axis motor fault | X-axis motor control detects coil open/short or motor fuse open | error |
6,002.43 | X-axis motor fault | X-axis motor control detects coil open/short or motor fuse open | error |
6,003.44 | Motor coil open or shorted; X-axis motor fuse open | X-axis motor fails to move during diagnostics | error |
6,005.68 | Door opened in Energy Star mode; unexpected firmware fault reported | Door opened while printer in Energy Star mode | warning |
6.01 | Duplex sensor detected but front panel not responding | POST duplex/front panel test | critical |
6,033.66 | XA unexpected ITC message; XA task protocol error | XA task received unexpected message while idle | error |
7,004.46 | Maintenance blade position sensor failed to detect drum-maintenance home flag transitions | Right I/O board sensor unable to detect flag transitions during power-on | error |
7.01 | Front panel detected but I/O Right not responding | POST I/O testing | error |
7,035.63 | Process motor negative delay error; negative delay argument passed to pm_sleep_for() | Software function called with invalid negative delay | error |
7,036.64 | Unexpected message in pm_sleep_for(); ITC communication error | Unexpected message received during pm_sleep_for() processing | error |
7,052.62 | Bad message ID in pm_update_dmc_status(); DMC status message mismatch | Received ITC message does not match expected DMC status message type | error |
8,002.67 | Generic cap task program fault; main CAP state sequencer entered fault state | Unexpected conditions detected during CAP movements such as home or goto | error |
8,022.60 | Unexpected CAP command while idle; invalid CAP command or message received | CAP task in idle state receives invalid command or unknown ITC message | error |
9 | NVRAM test failure (Phaser 840 only) | Walking 1s/0s test fails on last 4 bytes in VxWorks section of NVRAM | error |
9,001.45 | Cyan ink-level sensor malfunction in cyan reservoir | Ink-level sensor in cyan reservoir reports fault | error |
9,002.46 | Magenta ink-level sensor malfunction in magenta reservoir | Ink-level sensor in magenta reservoir reports fault | error |
9,003.47 | Yellow ink-level sensor malfunction in yellow reservoir | Ink-level sensor in yellow reservoir reports fault | error |
9,004.48 | Black ink-level sensor malfunction in black reservoir | Ink-level sensor in black reservoir reports fault | error |
9,005.40 | Cyan ink-melt heater jam; heater on but no ink dripping | Cyan heater energized but no ink output detected | error |
9,006.41 | Magenta ink-melt heater jam; heater on but no ink dripping | Magenta heater energized but no ink output detected | error |
9,007.42 | Yellow ink-melt heater jam; heater on but no ink dripping | Yellow heater energized but no ink output detected | error |
9,008.43 | Black ink-melt heater jam; heater on but no ink dripping | Black heater energized but no ink output detected | error |
PE 1 rapid blink | CPU Bridge and/or PCI bus communication failure | BIST execution during power-up | critical |
PE 2 rapid blinks | ROM not responding | BIST execution during power-up | critical |
PE 3 rapid blinks | System hangs during code initialization | BIST execution during power-up | critical |
PS/PE 1 blink each then off | Power supply shutdown due to regulation failure | DC power applied; power supply could not remain regulated | critical |
PS/PE on solid | Printer held in reset mode | System power-up | critical |
RAM ERROR | RAM socket has no supported SODIMM installed | POST RAM testing at power-up | critical |
Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI