Siemens Healthineers Arcadis Orbic: troubleshooting and error codes
The ServiceForge knowledge base holds 106 documented symptoms for the Siemens Healthineers Arcadis Orbic, with 157 ranked causes, 172 diagnostic checks with test points and expected values, and 128 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
Image transfer from remote system to local system fails
DICOM image transfer aborts; session terminated by sender; error messages appear in UI and event log
Ranked causes
- 1. Configuration problem with remote system (common)
- 2. Network connectivity issue (common)
- 3. Presentation Context rejected during Association Negotiation (occasional)
- 4. Wrong or missing command set request at T7 level (occasional)
- 5. Transfer Syntax causes problems or is required but not sent (occasional)
- 6. Timeout in message stream (occasional)
- 7. Timeout waiting for transfer response (occasional)
- 8. Local system fails to enter image in local database (occasional)
Verify remote system configuration at local system
- Test point
- Network Nodes configuration
- Expected
- Remote system correctly configured
6 more checks with pass and fail actions, 10 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
TCP/IP ping fails
Connection failed error messages in UI; remote node does not respond. Event log shows association errors; merge log shows TCP init errors or timeout.
Ranked causes
- 1. Network problems or configuration error (common)
- 2. Wrong IP address, subnet mask, or gateway configuration (common)
- 3. Network cable not connected at hub or switch (occasional)
- 4. Domain Name Service (DNS) misconfiguration or failure (occasional)
- 5. Gateway not accessible or incorrectly configured (occasional)
- 6. Network collisions or poor performance (occasional)
- 7. Problem in remote system (occasional)
Examine merge log for TCP/IP init error
- Test point
- merge_stu.log, merge_hc.log, merge_HRI.log
- Expected
- No 'TCP/IP init error' or 'timeout in select()' messages
5 more checks with pass and fail actions, 9 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DICOM verification fails with TCP/IP ping OK
UI shows 'No response from node name'; Event log shows 'Could not open association with remote node / service not acceptable'; Merge log shows 'E: TCP init error'
Ranked causes
- 1. AET or port number of remote system is wrong (common)
- 2. Remote process is not running (common)
- 3. Remote system does not support DICOM verification (SCP) (rare)
- 4. Remote system is SCU only; C_ECHO not supported (occasional)
Verify AET and port number configuration
- Test point
- Service Tool Configuration
- Expected
- Remote system AET and port match Conformance Statement
1 more check with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Search platform logical name breaks down during searching
UI and Event log show 'Logical name breaks down during searching'; Merge log shows 'E: Peer aborted association'
Ranked causes
- 1. Any error on DICOM level (unknown)
- 2. Local SCU does not send TCP/IP packets or network switch does not forward message (occasional)
- 3. Network switch does not forward DICOM verification message (occasional)
- 4. Our local AET not correctly configured at remote system (occasional)
Review DICOM merge.log for error messages
- Test point
- merge_stu.log, merge_hc.log, merge_HRI.log
- Expected
- Error message describing DICOM-level issue
2 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
C-arm motion limit switches not functioning caution
C-arm does not stop at mechanical limits or limit switches fail to activate before mechanical end-stop is reached.
Ranked causes
- 1. Limit switch misadjusted (common)
- 2. Limit switch cabling faulty or disconnected (common)
- 3. Limit switches installed upside-down or reversed (occasional)
Test limit switch activation during C-arm motion
- Test point
- Limit switches on C-arm assembly
- Expected
- Limit switches engage before C-arm reaches mechanical limit stop
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: C-arm limit switch verification caution
Manual C-arm orbital movement and limit switch actuation requires verification
Ranked causes
- 1. Limit switch not actuating at proper position (occasional)
- 2. Limit switch misalignment (occasional)
- 3. Limit switch cable fault (occasional)
Remove cable module cover
- Test point
- Cable module enclosure
- Expected
- Cover removed safely, mechanical components accessible
3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Coupling unit defective or 24V power missing high voltage
Coupling unit is not functioning; either 24V supply is absent or unit hardware is faulty.
Ranked causes
- 1. Fuse F2 on PCB D200 is open (common)
- 2. 24V supply voltage missing at coupling unit (common)
- 3. Coupling unit hardware failure (occasional)
Check fuse F2 on printed circuit board D200
- Test point
- PCB D200 fuse F2
- Expected
- Fuse intact and not open
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Disk space low on C: or D: drive
System may have insufficient free space for operations; affects file storage and temporary operations.
Ranked causes
- 1. Temp directory contains large files (common)
- 2. Patient data stored locally instead of archived (occasional)
- 3. CD-ROM write jobs remain in AN_CDR_DIR after process complete (occasional)
Verify free space on C: drive meets minimum
- Test point
- C: drive Properties
- Expected
- at least 15% of capacity as free space
1 more check with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
FTP transfer fails
IP connection to SRS server is working but functional check of FTP transfer fails; cannot upload diagnostic data via FTP protocol
Ranked causes
- 1. FTP configuration is incorrect (common)
- 2. FTP account or password settings incorrect (common)
- 3. FTP port blocked by firewall in hospital network (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
IP connection to SRS server fails
System cannot establish network connection to remote service server at 194.138.39.18; tracert command shows 'Destination host unreachable' after maximum hops
Ranked causes
- 1. Default gateway or static route not correctly defined (common)
- 2. Customer router not correctly installed or configured (common)
- 3. Hospital routing incorrect when system and router not in same network (occasional)
Verify static route configuration
- Test point
- Command interpreter
- Expected
- route print output showing configured gateway
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
No network connection available
System cannot communicate with network resources; affects patient archiving and data sharing.
Ranked causes
- 1. Network cable disconnected or faulty (common)
- 2. TCP/IP configuration incorrect (common)
- 3. Navigation system not responding (occasional)
Test connection to navigation system
- Test point
- Service software Configuration > Network nodes
- Expected
- Host name and TCP/IP address displayed; Test successful
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
No network transfer via DICOM
DICOM services cannot transfer data over TCP/IP network; remote systems are unreachable
Ranked causes
- 1. Network problems (common)
- 2. Configuration problem (common)
- 3. DICOM process not started (occasional)
Verify network connectivity using TCP/IP ping
- Test point
- Remote DICOM nodes
- Expected
- Ping response received
3 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
USB-to-CAN adapter not functioning
Communication with CAN bus or navigation system fails; indicator light not green or device not recognized by system.
Ranked causes
- 1. USB-to-CAN module LED not green (common)
- 2. USB-to-CAN module driver not installed or corrupted (common)
- 3. Cable connection issue between main system and imaging system (common)
Verify USB-to-CAN module LED indicator
- Test point
- USB-to-CAN compact module
- Expected
- LED is green
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Access to CS knowledge base fails
Intranet address entered for CS knowledge base is not reachable; tracert output shows 'Destination host unreachable'
Ranked causes
- 1. Intranet address entered is incorrect (common)
- 2. Internet Explorer configuration is incorrect (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
CAN bus connection to main system not established
System cannot communicate with main system via CAN bus; coupling or communication failure.
Ranked causes
- 1. Monitor trolley not connected to main system or cable faulty (common)
- 2. USB-to-CAN adapter not connected or LED not green (common)
Verify physical connection to main system
- Test point
- Main system connection cable at monitor trolley rear
- Expected
- Cable securely connected; no bent contacts at plug
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Capture DICOM traffic for remote analysis by specialist
DICOM transfer fails and local troubleshooting is insufficient; specialist requires captured network traffic or local test receiver data
Ranked causes
- 1. Specialist needs detailed packet or log analysis to diagnose network or protocol issues (unknown)
- 2. Network traffic capture not possible; alternative is to capture image with test receiver (occasional)
If possible, capture DICOM transfer using network analyzer (snoop or NetXray)
- Test point
- Network interface on sending or receiving system
- Expected
- Captured DICOM packet trace file (.pcap or .cap format)
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DICOM image transfer fails with wrong or missing command set request
T7 level command set request is incorrect or not sent; association may have failed at T3 level
Ranked causes
- 1. T7 command set not sent because Association Negotiation (T3) failed (common)
- 2. Extended negotiation SCU/SCP roles not supported by peer system (occasional)
Enable T3 and T7 trace levels in merge_stu.log; send test image
- Test point
- syngo DICOM Service Tools - Storage - Extend Trace Level, merge_stu.log
- Expected
- T3 shows Association Negotiation succeeded; T7 shows command set request sent
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DICOM image transfer timeout in message stream or waiting for response
Transfer stalls or times out in the middle of the message stream; timeout while waiting for successful transfer response
Ranked causes
- 1. Inactivity timeout too short for slow network or large image (occasional)
- 2. Read PDU timeout too short; remote system slow to respond (occasional)
Examine merge_stu.log for timeout error: 'timeout in the middle of the stream'
- Test point
- merge_stu.log Analysis tool
- Expected
- Log shows timeout error location and timestamp
3 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DICOM image transfer to remote system fails at association negotiation
DICOM association negotiation fails during image transfer to remote DICOM system; session aborted by sender
Ranked causes
- 1. Network connectivity issue between systems (common)
- 2. Association negotiation protocol failure or service incompatibility (occasional)
Verify network connectivity (see network troubleshooting reference)
- Test point
- Network link between systems
- Expected
- Network connection established and stable
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DICOM image transfer to remote system fails during association negotiation
Session aborted by sender with error 'Session aborted by sender (40003) and service is unacceptable (30023)' during T3 association negotiation phase
Ranked causes
- 1. Network connectivity issue between systems (common)
- 2. DICOM Association Negotiation parameters mismatch or Presentation Context rejected (occasional)
Enable trace level T3 in merge_stu.log to capture Association Negotiation Request/Response
- Test point
- syngo DICOM Service Tools - Storage - Extend Trace Level
- Expected
- T3 trace enabled; merge_stu.log file available
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DICOM remote system cannot process transferred image or service failures
Remote system receives image but fails to store or display it; remote system database insertion fails; service errors occur on remote side
Ranked causes
- 1. Remote system internal database error or local process interference (occasional)
- 2. Remote system unable to validate or display image attributes (occasional)
Try sending image from different modality or application
- Test point
- Remote DICOM storage provider, AET and port
- Expected
- Image from different source accepted and stored on remote system
4 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DICOM retrieve of selected data fails
Query/retrieve operation does not complete; images not transferred to local system
Ranked causes
- 1. C_MOVE request fails due to incorrect AETs (common)
- 2. C_STORE fails on separate association (common)
Verify network level connectivity
- Test point
- Network path between systems
- Expected
- Network connectivity established
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Emergency stop button inoperative patient safety
Pressing emergency stop button does not block vertical lift, or lift cannot be resumed after release
Ranked causes
- 1. Emergency stop switch electrical circuit fault (rare)
- 2. Emergency stop button release mechanism stuck (occasional)
Press emergency stop switch
- Test point
- Emergency stop button
- Expected
- Vertical lift motor stops and does not respond to raise/lower buttons
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
I.I. laser light localizer function defective
Laser diodes non-functional or laser light fan beams not adjustable to focal point of tube housing
Ranked causes
- 1. Laser diodes failed (occasional)
- 2. Laser beam alignment out of adjustment (occasional)
Test laser diode function
- Test point
- Laser diodes
- Expected
- Laser diodes emit light
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
I.I. laser light localizer mechanics damaged caution
Image intensifier laser light localizer shows mechanical damage, loose components, or improper seating
Ranked causes
- 1. Impact or wear on I.I. laser light localizer (unknown)
- 2. I.I. ring loose or damaged (occasional)
Inspect I.I. laser light localizer for damage
- Test point
- Integrated I.I. laser light localizer
- Expected
- No visible damage
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
No 24V supply at D10 connector
System electronics does not provide required 24V power to 3D drive subsystem
Ranked causes
- 1. System electronics D200 defective (common)
- 2. Fuse F1 open on D200 (occasional)
Inspect fuse F1 on printed circuit board D200
- Test point
- fuse F1, D200
- Expected
- fuse intact
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
USB-to-CAN module not detected or not functioning
CAN board fails to appear in control panel or test returns unsuccessful results
Ranked causes
- 1. USB-to-CAN module driver not installed or module disconnected (common)
- 2. USB-to-CAN module hardware failure (rare)
Verify USB-to-CAN module appears in Interfaces control panel
- Test point
- Control panel Interfaces dialog
- Expected
- Board appears in dialog box
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
3D license not recognized after upgrade to Orbic 3D
System does not properly recognize the 3D license after an upgrade to the system type Orbic 3D
Ranked causes
- 1. System type not applied after upgrade (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
3D reconstruction function
3D reconstruction system must function properly and meet performance specifications
Ranked causes
- 1. 3D reconstruction system malfunction or error (unknown)
Test 3D reconstruction system
- Test point
- 3D reconstruction hardware and software
- Expected
- System produces valid 3D images
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
3D reconstruction with navigation system
3D reconstruction in combination with navigation system must function properly
Ranked causes
- 1. Combined 3D and navigation system malfunction (unknown)
Test integrated 3D and navigation
- Test point
- 3D reconstruction and navigation system
- Expected
- Systems integrate and function properly
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Accessory condition patient safety
Undamaged accessories must be in use to ensure safe operation
Ranked causes
- 1. Damaged or defective accessories in use (unknown)
Verify accessories are undamaged
- Test point
- All installed accessories
- Expected
- All accessories undamaged and functional
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
C-arm movement restricted or noisy caution
C-arm movements exhibit slackness in bearings, noise during operation, or resistance to smooth motion
Ranked causes
- 1. Bearing wear or contamination (occasional)
Test C-arm movement through full range
- Test point
- C-arm bearings and joints
- Expected
- Smooth movement with no slackness or noise
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cable and cable guide integrity high voltage
Cables and cable guides may be loose or damaged, affecting electrical safety
Ranked causes
- 1. Loose or damaged cables and cable guides (unknown)
Inspect cables and cable guides
- Test point
- All cable routing and guides
- Expected
- All cables secure and undamaged
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cable deflectors damaged or misaligned caution
Physical damage or improper positioning of cable deflectors on stand or monitor trolley
Ranked causes
- 1. Impact or wear damage to cable deflectors (unknown)
Inspect cable deflectors for damage and proper positioning
- Test point
- Stand and monitor trolley cable deflectors
- Expected
- Intact, properly secured, no cracks or deformation
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cable deflectors damaged or missing caution
Cable deflectors on stand or monitor trolley show visible damage, cracks, or are missing
Ranked causes
- 1. Wear or impact damage (unknown)
Visual inspection of cable deflectors
- Test point
- Stand and monitor trolley cable deflectors
- Expected
- Intact with no visible damage
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cable, belt, and spindle wear caution
Wire cables, belts, and spindles must be free of wear and tear
Ranked causes
- 1. Worn or damaged cables, belts, or spindles (unknown)
Inspect cables, belts, and spindles
- Test point
- Lifting column, 3D reconstruction system
- Expected
- No visible wear or damage
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: 3D adjustment repeat
3D adjustment and orbital movement calibration repeated after limit switch verification
Ranked causes
- 1. 3D adjustment re-verification required after hardware work (unknown)
Access 3D adjustment menu
- Test point
- Service software Main system
- Expected
- 3D adjustment/potentiometer option accessible
3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Angulation potentiometer adjustment
Orbital and angulation potentiometers require adjustment via service software
Ranked causes
- 1. Potentiometer calibration required (unknown)
Access potentiometer adjustment menu
- Test point
- Service software Main system menu
- Expected
- 3D adjustment/potentiometer option available
2 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: C-arm position alignment caution
C-arm requires positioning according to service UI reference image
Ranked causes
- 1. C-arm position misalignment (unknown)
Display service UI reference position
- Test point
- Service UI screen
- Expected
- Reference image of correct C-arm position visible
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Edge enhancement filter configuration
Maximum number of edge enhancement filters per examination set requires adjustment
Ranked causes
- 1. Edge enhancement filter count needs configuration (unknown)
Open service software
- Test point
- Configuration menu
- Expected
- Service software displays Configuration option
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Laser light localizer (April 2006 models)
Verify and adjust laser diode function and beam alignment on image intensifier focal point
Ranked causes
- 1. Routine maintenance per service schedule (common)
Test laser diode operation
- Test point
- Laser diodes in localizer
- Expected
- Diodes emit visible light
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: LUT configuration
Maximum number of LUTs per examination set requires adjustment in service software
Ranked causes
- 1. LUT count needs configuration (unknown)
Open service software
- Test point
- Configuration menu
- Expected
- Service software displays Configuration option
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: System calibration
3D imaging system or navigation system requires full calibration procedure
Ranked causes
- 1. System calibration needed (unknown)
Access system calibration menu
- Test point
- Service software Main system
- Expected
- 3D calibration option for ORBIC 3D visible
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Use PC Diagnosis software
Diagnostic maintenance procedure using PC Diagnosis software to check system health including drivers and hard drive
Ranked causes
- 1. Routine maintenance or system verification required (unknown)
Codonics printer hardcopy printing fails from base unit
Printing may fail when hardcopy is initiated from the base unit if the Codonics printer parameter is not properly configured
Ranked causes
- 1. Parameter "Hardcopy button sends image to film task card" not activated on Codonics printer (unknown)
Verify Hardcopy button parameter is activated
- Test point
- Codonics printer settings
- Expected
- Parameter "Hardcopy button sends image to film task card" is enabled
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Codonics printer print job fails from base unit
Printing may fail when initiated from base unit if Hardcopy button parameter not configured
Ranked causes
- 1. Hardcopy button parameter not enabled on Codonics printer (common)
Verify Hardcopy button parameter status
- Test point
- Codonics printer settings
- Expected
- Hardcopy button sends image to film task card enabled
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Collision protection functioning patient safety
Collision protection system must properly stop system movements when activated
Ranked causes
- 1. Collision protection system malfunction or damage (unknown)
Verify collision protection presence
- Test point
- Collision protection system
- Expected
- System present and functional if installed
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cover panels damaged caution
Physical damage visible on cover panels of stand or monitor trolley
Ranked causes
- 1. Impact or wear damage to cover panels (unknown)
Inspect cover panels for mechanical damage
- Test point
- ARCADIS Orbic stand and monitor trolley covers
- Expected
- No cracks, dents, or breaks
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
DICOM image transfer fails with non-zero status code in command set response
T7 level command set response returns status code other than 0 (success); transfer was rejected or resource error occurred
Ranked causes
- 1. Status 0xA7xx indicates out of resources on remote system or incorrect attribute in dataset (occasional)
Enable T2, T3, and T7 trace levels; send test image and capture response status code
- Test point
- merge_stu.log, T7 status code field
- Expected
- T7 response status = '0' for successful transfer
2 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DICOM transfer fails due to transfer syntax encoding problems or JPEG decoding
Image transfer fails with value representation or JPEG decoding error; explicit VR transfer syntax causes problems
Ranked causes
- 1. Remote system does not support explicit VR or JPEG transfer syntax (occasional)
Review transfer syntax setting in syngo Configuration DICOM network nodes
- Test point
- syngo Configuration > DICOM > network nodes
- Expected
- Currently enabled transfer syntax is either explicit VR or JPEG
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Driver error detected in Device Manager
One or more files displayed in Device Manager marked in red or with question mark, indicating driver malfunction
Ranked causes
- 1. Missing or corrupted device driver (unknown)
Open Device Manager and inspect for error indicators
- Test point
- Device Manager display
- Expected
- No files marked in red or with question mark
- Tools
- Windows Device Manager
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Dual monitor setting lost
Dual monitor configuration is not retained, typically after monitor replacement or system fault.
Ranked causes
- 1. Defective monitor or monitor replacement (common)
Access service software utilities menu
- Test point
- Service software interface
- Expected
- Utilities menu accessible
2 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Emergency stop switch functional patient safety
Emergency stop switches must be fully functional for operator safety
Ranked causes
- 1. Damaged or non-responsive emergency stop switch (unknown)
Test emergency stop switch activation
- Test point
- Emergency stop button
- Expected
- System stops immediately when activated
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Error 0001 appears after main system software download
Error 0001 displayed on base unit display following main system software download
Ranked causes
- 1. Software download incomplete or system state not refreshed (common)
Verify error 0001 is displayed on base unit
- Test point
- base unit display
- Expected
- Error 0001 visible
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Error code 30023 in DICOM session
DICOM session error 30023 - service unacceptable
Ranked causes
- 1. DICOM service or presentation context not supported by remote system (unknown)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Error code 40003 in DICOM session
DICOM session aborted by sender with error code 40003
Ranked causes
- 1. Service unacceptable or association negotiation failure (unknown)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Foot brakes ineffective patient safety
ARCADIS Orbic stand or monitor cart moves or rolls when brakes applied on flat surface
Ranked causes
- 1. Brake pads worn or brake mechanism faulty (occasional)
Test foot brake effectiveness
- Test point
- Foot brakes on stand and monitor cart
- Expected
- Equipment remains stationary when brakes engaged on flat surface
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Ground wire resistance measurement high voltage
Protective conductor resistance must be measured and evaluated
Ranked causes
- 1. Elevated or excessive ground wire resistance (unknown)
Measure ground wire resistance
- Test point
- Protective conductor circuit
- Expected
- Resistance within acceptable limits
- Tools
- Ground resistance meter
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Hard drive errors or bad sectors
Hard drive contains file system errors or bad sectors that may affect system performance or data integrity
Ranked causes
- 1. File system errors or corrupted sectors on hard drive (unknown)
Run disk check utility on hard drive
- Test point
- Hard drive
- Expected
- Checking disk completes without critical errors
- Tools
- Windows Disk Check
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Hard drive fragmentation
Hard drive file system is fragmented, potentially affecting access speed and system performance
Ranked causes
- 1. File fragmentation on hard drive (unknown)
Analyze hard drive fragmentation status
- Test point
- Hard drive
- Expected
- Analysis indicates defragmentation needed or not needed
- Tools
- Windows Defragmentation Utility
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
More symptoms
- Host name or IP address changes not applied
- ID labels missing or illegible
- Images loaded in viewing application consuming resources
- Imaging system PC defect
- Integrated I.I. laser light localizer function check
- Integrated I.I. laser light localizer mechanics damaged
- Integrated laser light localizer near tube function check
- IP address conflict detected
- IQ quick test
- Laser light localizer near tube mechanics damaged
- Leakage current exceeds limit
- Leakage current measurement
- Lifting column noisy or obstructed
- Mechanical parts clean and lubricated
- Mobile equipment wheels and brakes
- Monitor 1 not properly recognized
- Monitor damaged or improperly mounted
- Monitor enters hibernate mode instead of shutting down
- Monitor trolley remains powered after system shutdown
- Motor does not move when starting 3D scan
- Navigation system I.I. ring damaged
- Operating controls and indicators functional
- Operator documentation availability
- Orbital potentiometer out of adjustment
- Orbital, angulation, swivel, or lift brakes below spec
- Performance problems with service software and 30 f/s fluoroscopy
- Protective conductor resistance exceeds limit
- Radiation protection devices present
- Remote system does not support DICOM features or roles required for transfer
- Removable I.I. laser light localizer mechanics damaged
- Restart Application via Local Service fails with Timeout error
- Safety cutoff devices functioning
- Safety distances maintained
- Shutdown fails with CD-ROM in CD/DVD drive
- System movements stop at end positions
- System start not guaranteed with Grace Period below 800
- System start-up failures with low Grace Period setting
- Table and system position reproducibility
- Unusual noise during operation
- USB-to-CAN driver problems
- Visual damage affecting safety
- Wall, ceiling, and floor mountings secure
- Warning devices functioning
- Warning labels missing or illegible
- Warning labels present and recognizable
- Wheels or castors defective
46 more symptoms with ranked causes and checks are in ServiceForge. Connect ServiceForge to your AI
Error codes
| Code | Meaning | Trigger | Severity |
|---|---|---|---|
0001 | Error following main system software download | After completion of main system software download to base unit | warning |
30023 | Service unacceptable | Remote DICOM system rejected the requested service or presentation context | error |
40003 | Session aborted by sender | DICOM Association negotiation fails or is rejected | error |
A7xx | Out of resources | Command set response contains error status | error |
Connection failed because the remote node does not exist | Remote system cannot be contacted | TCP/IP ping fails to reach remote node | error |
Could not open association with remote node | DICOM association with remote system failed | Network or remote system problem prevents connection establishment | error |
E: TCP init error | TCP/IP initialization failed | Network connectivity or configuration problem | error |
[MC_ALREADY_REGISTERED] | Application was already registered | unknown | |
[MC_ASSOCIATION_ABORTED] | Association was aborted | unknown | |
[MC_ASSOCIATION_CLOSED] | Association was closed by peer | unknown | |
[MC_ASSOCIATION_REJECTED] | Association negotiation failed | unknown | |
[MC_ATTRIBUTE_HAS_VALUES] | Attribute has value(s) - VR cannot be changed to SQ | unknown | |
[MC_BAD_DIR_RECORD_TYPE] | Invalid directory record type | unknown | |
[MC_BUFFER_TOO_SMALL] | Value too large for buffer | unknown | |
[MC_CALLBACK_CANNOT_COMPLY] | Callback cannot comply | unknown | |
[MC_CALLBACK_DATA_SIZE_NEGATIVE] | Callback provided negative data size | unknown | |
[MC_CALLBACK_DATA_SIZE_UNEVEN] | Callback provided uneven data size | unknown | |
[MC_CALLBACK_PARM_ERROR] | Invalid parameter from callback | unknown | |
[MC_CALLBACK_REGISTERED] | Not allowed if callback is registered | unknown | |
[MC_CANNOT_COMPLY] | Callback cannot comply with request | unknown | |
[MC_CANT_ACCESS_PROFILE] | Cannot access MergeCOM services file | unknown | |
[MC_CONFIG_INFO_ERROR] | Invalid configuration parameter | unknown | |
[MC_CONFIG_INFO_MISSING] | Required configuration info missing | unknown | |
[MC_CONNECTION_FAILED] | Failed to connect to remote host | unknown | |
[MC_DDFILE_ERROR] | Problem with data dictionary file | unknown | |
[MC_DOES_NOT_VALIDATE] | Message contains validation errors | unknown | |
[MC_EMPTY_VALUE] | Attribute has no value yet | unknown | |
[MC_END_OF_DATA] | End of data | unknown | |
[MC_END_OF_LIST] | End of list has been reached | unknown | |
[MC_ENTITY_ALREADY_EXISTS] | Lower level directory entity already exists | unknown | |
[MC_EXT_INFO_UNAVAILABLE] | Extended negotiation information unavailable | unknown | |
[MC_FOUND] | Private block found | unknown | |
[MC_FUNCTION_UNAVAILABLE] | Function not available on this machine | unknown | |
[MC_INACTIVITY_TIMEOUT] | Timed out waiting on network partner in middle of a transfer | unknown | |
[MC_INCOMPATIBLE_VALUE] | Tag's value incompatible with function call | unknown | |
[MC_INCOMPATIBLE_VR] | Tag's VR incompatible with function call | unknown | |
[MC_INVALID_APPLICATION_ID] | Application ID parameter is invalid | unknown | |
[MC_INVALID_APPLICATION_TITLE] | Application Title parameter is invalid | unknown | |
[MC_INVALID_ASSOC_ID] | Association ID parameter is invalid | unknown | |
[MC_INVALID_CHARS_IN_VALUE] | Invalid characters in value for this VR | unknown | |
[MC_INVALID_COMMAND] | Invalid command parameter | unknown | |
[MC_INVALID_DATA_TYPE] | Invalid data type parameter | unknown | |
[MC_INVALID_DICOMDIR_ID] | DICOMDIR ID parameter invalid | unknown | |
[MC_INVALID_DIRECTORY_RECORD_OFFSET] | Directory record offset doesn't match a directory record | unknown | |
[MC_INVALID_ENTITY_ID] | Entity ID parameter invalid | unknown | |
[MC_INVALID_FILE] | Invalid DICOM file: did not contain DICM in prefix | unknown | |
[MC_INVALID_FILE_ID] | File ID parameter invalid | unknown | |
[MC_INVALID_GROUP] | Private group not an odd number | unknown | |
[MC_INVALID_HOST_NAME] | Host name parameter invalid | unknown | |
[MC_INVALID_ITEM_ID] | Item ID parameter invalid | unknown | |
[MC_INVALID_LENGTH_FOR_TITLE] | Application title not 1-16 bytes long | unknown | |
[MC_INVALID_LENGTH_FOR_VR] | Invalid VR length in stream data | unknown | |
[MC_INVALID_LICENSE] | Invalid license number specified in ASSOC_PARMS | unknown | |
[MC_INVALID_LOWER_DIR_RECORD] | Invalid lower-level directory record type | unknown | |
[MC_INVALID_MESSAGE_ID] | Message ID parameter invalid | unknown | |
[MC_INVALID_MESSAGE_RECEIVED] | Network partner sent an invalid message | unknown | |
[MC_INVALID_MRDR_ID] | MRDR ID parameter invalid | unknown | |
[MC_INVALID_PAD] | Invalid number for padding, must be even | unknown | |
[MC_INVALID_PARAMETER_NAME] | Invalid name parameter value | unknown | |
[MC_INVALID_PORT_NUMBER] | Port number parameter not positive | unknown | |
[MC_INVALID_PRIVATE_CODE] | Invalid private group code | unknown | |
[MC_INVALID_SERVICE_LIST_NAME] | Invalid service list name parameter | unknown | |
[MC_INVALID_SOP_CLASS_UID] | SOP class UID parameter is invalid | unknown | |
[MC_INVALID_TAG] | Tag parameter invalid | unknown | |
[MC_INVALID_TRANSFER_SYNTAX] | Invalid transfer syntax code | unknown | |
[MC_INVALID_VALUE_FOR_VR] | Invalid value for this tag's VR | unknown | |
[MC_INVALID_VALUE_NUMBER] | Invalid value number for the attribute | unknown | |
[MC_INVALID_VERSION] | Invalid version of utilities used to generate configuration functions | unknown | |
[MC_INVALID_VR_CODE] | VR parameter is invalid | unknown | |
[MC_LIBRARY_ALREADY_INITIALIZED] | MC_Library_Initialization has already been called | unknown | |
[MC_LIBRARY_NOT_INITIALIZED] | MC_Library_Initialization not called yet | unknown | |
[MC_LOG_EMPTY] | No messages have been logged | unknown | |
[MC_MESSAGE_EMPTY] | The message object is empty | unknown | |
[MC_MESSAGE_VALIDATES] | Message validates | unknown | |
[MC_MISSING_CONFIG_PARM] | Required parameter missing in merge.ini | unknown | |
[MC_MSGFILE_ERROR] | Problem with message information file | unknown | |
[MC_MUST_BE_POSITIVE] | Value is not positive | unknown | |
[MC_NETWORK_SHUT_DOWN] | Network unexpectedly shutdown | unknown | |
[MC_NO_APPLICATIONS_REGISTERED] | No applications registered | unknown | |
[MC_NO_CALLBACK] | Attribute has no callback registered | unknown | |
[MC_NO_CONDITION_FUNCTION] | Warning: no function specified for Type 1C or Type 2C attribute | warning | |
[MC_NO_FILE_SYSTEM] | No file system available to perform requested function | unknown | |
[MC_NO_INFO_REGISTERED] | No negotiation information registered for the service | unknown | |
[MC_NO_LICENSE] | License not found in ASSOC_PARMS | unknown | |
[MC_NO_MERGE_INI] | MERGE.INI file cannot be located | unknown | |
[MC_NO_MORE_ATTRIBUTES] | Message has no more attributes | unknown | |
[MC_NO_MORE_VALUES] | Attribute has no more values | unknown | |
[MC_NON_SERVICE_ATTRIBUTE] | Invalid attribute for service | unknown | |
[MC_NO_PROFILE] | Could not access MergeCOM Profile | unknown | |
[MC_NO_REQUEST_PENDING] | No association request to accept/reject | unknown | |
[MC_NOT_FOUND] | Private block not found | unknown | |
[MC_NOT_ONE_OF_DEFINED_TERMS] | Value not one of defined terms | unknown | |
[MC_NOT_ONE_OF_ENUMERATED_VALUES] | Value not an enumerated value | unknown | |
[MC_NULL_POINTER_PARM] | Null parameter | unknown | |
[MC_NULL_VALUE] | Attribute's value is NULL | unknown | |
[MC_OUT_OF_ORDER_TAG] | A tag was encoded in the stream not in ascending order | unknown | |
[MC_PROTOCOL_ERROR] | Protocol violation: Call made out of sequence | unknown | |
[MC_REQUIRED_ATTRIBUTE_MISSING] | Required attribute not in message | unknown | |
[MC_REQUIRED_DATASET_MISSING] | Missing required data set for this message command | unknown | |
[MC_REQUIRED_VALUE_MISSING] | Required attribute has no value | unknown | |
[MC_STATE_VIOLATION] | Function call invalid now | unknown | |
[MC_SYSTEM_CALL_INTERRUPTED] | System call was interrupted | unknown | |
[MC_SYSTEM_ERROR] | System error | unknown | |
[MC_TAG_ALREADY_EXISTS] | Tag already exists | unknown | |
[MC_TEMP_FILE_ERROR] | Temporary file I/O error | unknown | |
[MC_TIMEOUT] | Timed out waiting on network partner | unknown | |
[MC_TOO_FEW_VALUES] | Attribute must have more values | unknown | |
[MC_TOO_MANY_BLOCKS] | No room for more private blocks | unknown | |
[MC_TOO_MANY_VALUES] | Too many values for this attribute | unknown | |
[MC_UNABLE_TO_CHECK_CONDITION] | Unable to check condition | unknown | |
[MC_UNABLE_TO_GET_ITEM_ID] | Function unable to get item ID from DICOMDIR object | unknown | |
[MC_UNACCEPTABLE_SERVICE] | Message service unacceptable for this association | unknown | |
[MC_UNEXPECTED_EOD] | Unexpected end of stream data | unknown | |
[MC_UNKNOWN_HOST_CONNECTED] | Unknown host attempted to connect | unknown | |
[MC_UNKNOWN_HOST_NAME] | Unable to resolve host name to ip address | unknown | |
[MC_UNKNOWN_ITEM] | Item is not configured | unknown | |
[MC_UNKNOWN_SERVICE] | Service is not configured | unknown | |
[MC_VALUE_MAY_NOT_BE_NULL] | Type 1[C] value may not be NULL | unknown | |
[MC_VALUE_NOT_ALLOWED] | Attribute must not be used under current condition | unknown | |
[MC_VALUE_OUT_OF_RANGE] | Out of range: Numeric precision would be lost | unknown | |
[MC_VALUE_TOO_LARGE] | Stream value length too large | unknown | |
[MC_VR_ALREADY_VALID] | Value representation is already valid | unknown | |
Read PDU timeout | Timeout occurred while waiting for response PDU after sending command set request | Remote system is not responding within the configured read PDU timeout interval | warning |
Service is unacceptable (30023) | Remote system rejected the DICOM service parameters offered by sending system | Incompatible service configuration, unsupported roles, or presentation context mismatch | error |
Session aborted by sender (40003) | DICOM association was aborted by the sending system during negotiation | Remote system rejects association parameters or presentation context during T3 negotiation phase | error |
Status A7xx | Remote DICOM system returned out-of-resources status code in command set response | Transfer was attempted but remote system cannot accept image due to resource constraints or attribute errors | error |
Timeout | Restart operation did not complete within expected time | Attempted restart via Local Service > Utilities > System > Restart Application | error |
Timeout in the middle of the message stream | Transfer was interrupted due to inactivity timeout while sending DICOM image data | No data transmitted for longer than inactivity timeout interval during transfer of large image or slow network | warning |
Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI
Community
0 fixes logged by technicians through their AI, with outcomes, for this model.
ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.