Physio-Control LIFEPAK 500: troubleshooting and error codes

The ServiceForge knowledge base holds 72 documented symptoms for the Physio-Control LIFEPAK 500, with 93 ranked causes, 107 diagnostic checks with test points and expected values, and 126 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI

Symptoms

Unit displays damage or wear patient safety

Visible defects on external surfaces preventing safe operation

Ranked causes

  1. 1. Damage to exterior surfaces (unknown)
  2. 2. Excessive wear (unknown)
  3. 3. Improper mechanical function (unknown)
  4. 4. Damaged connectors (unknown)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Unit does not power on patient safety

Device fails to charge or respond to operation

Ranked causes

  1. 1. Defective test set or setup issue (common)
  2. 2. Patient interface connector damaged (occasional)
  3. 3. Energy storage capacitor issue (occasional)
  4. 4. Main PCW defective (occasional)
First check

Verify test set-up and reset

Test point
test setup
Expected
test setup correct

3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Fault codes recorded in LIFEPAK 500

LIFEPAK 500 AED has recorded one or more fault codes during internal self-test or routine use. Fault codes are stored in the Fault Code Log and may indicate transient electromagnetic interference or electrostatic discharge. Codes may not indicate permanent equipment failure.

Ranked causes

  1. 1. Transient electromagnetic interference (EMI) (occasional)
  2. 2. Electrostatic discharge (ESD) (occasional)
  3. 3. Permanent hardware error (rare)
First check

Review recorded fault code(s) in Fault Code Log

Test point
Fault Code Log memory
Expected
Fault code present with date and time of occurrence

1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: AED impedance patient safety

Verify AED output impedance matches specification using decade resistance box and test adapter

Ranked causes

  1. 1. Impedance calibration required per service procedure (common)
  2. 2. Impedance not within specification (unknown)
First check

Verify AED impedance output at test post

Test point
QUIK-COMBO test post adapter
Expected
225 OHMS Ω
Tools
decade resistance box set to 225 Ω, VP78-QUIK-COMBO test post adapter

5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: Energy meter baseline and component connection high voltage

Connect all components to LIFEPAK 500 patient connector and establish energy meter baseline

Ranked causes

  1. 1. Components must be connected to patient connector for testing (common)
  2. 2. Energy meter baseline must be established using LIFEPAK energy meter (common)
First check

Unplug all components from LIFEPAK 500 patient connector

Test point
LIFEPAK 500 patient connector
Expected
all components disconnected

1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: LIFEPAK 500 boot routine after battery replacement patient safety

Restore normal operation after battery has been replaced in the unit

Ranked causes

  1. 1. Battery replacement requires boot routine execution (common)
  2. 2. Verify battery status message (common)
First check

Insert fully functional battery

Test point
Battery compartment
Expected
Battery inserted, does not return battery fault indications

3 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: LIFEPAK 500 energy output patient safety

Verify defibrillator delivers specified energy level when PUSH TO SHOCK button is activated during test mode

Ranked causes

  1. 1. Energy calibration out of specification (unknown)
  2. 2. Calibration procedure execution (unknown)
First check

Access energy calibration screen

Test point
LIFEPAK 500 user interface
Expected
CALIBRATE ENERGY screen displayed

3 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Cannot set time or date

Unit will not accept or retain time and date settings

Ranked causes

  1. 1. Time/Date clock battery dead or missing (common)
  2. 2. Key switch installation improper (occasional)
First check

Verify Time/Date clock battery

Test point
Battery compartment
Expected
Battery present and functional

2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Charge time exceeds specification patient safety

AED takes longer than 15 seconds to charge to 360 J

Ranked causes

  1. 1. Battery voltage low or charger circuit slow (common)
  2. 2. High-voltage charging circuit degradation (occasional)
First check

Measure charge time from power button to delivery

Test point
AED output; timer
Expected
360 J in 15 seconds or less, ≤15 s
Tools
Stopwatch or analyzer with timing function

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Defib output insufficient or weak patient safety

Defibrillator produces reduced or no therapeutic output

Ranked causes

  1. 1. Battery low or failing (unknown)
  2. 2. Electrode pads defective or expired (unknown)

Electrode impedance test fails patient safety

AED does not respond correctly to electrode impedance tests or readings are incorrect

Ranked causes

  1. 1. Electrode cable or connector defect (common)
  2. 2. Impedance measurement circuit failure (occasional)
First check

Visually inspect electrode cables and connectors

Test point
Electrode connectors on AED
Expected
No visible damage, corrosion, or loose connections

1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Electrode pads not detected patient safety

Electrodes fail to register or are not recognized

Ranked causes

  1. 1. Electrode pads not seated properly (unknown)
  2. 2. Low battery or weak battery (unknown)

Energy output and charge time deficient patient safety

Defibrillator will not charge or charges slowly

Ranked causes

  1. 1. Faulty functional battery (common)
  2. 2. Energy storage capacitor defective (occasional)
First check

Verify battery is fully charged

Test point
battery status
Expected
fully functional battery

1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Energy output incorrect patient safety

AED does not deliver specified energy levels to patient

Ranked causes

  1. 1. Capacitor charge or discharge circuit failure (common)
  2. 2. Energy calibration drift (occasional)
First check

Measure energy output at 360 J setting

Test point
Defibrillator analyzer input
Expected
342–378 J for monophasic; 342–378 J for biphasic shock 2, Monophasic 360 J ±5%; Biphasic 100 J ±5%, 360 J ±5%
Tools
Defibrillator analyzer

1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Firmware or system error

Device firmware or internal system malfunction

Ranked causes

  1. 1. Firmware corruption or error (rare)
  2. 2. Internal voltage reference error (rare)
First check

Run system diagnostics

Test point
Device self-test
Expected
All systems pass

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Lead-to-lead leakage current excessive high voltage

Leakage current between electrode leads exceeds safe limit

Ranked causes

  1. 1. Electrode cable insulation breakdown or contamination (occasional)
  2. 2. High-voltage output circuit isolation fault (rare)
First check

Measure lead-to-lead leakage current

Test point
Electrode output connectors
Expected
does not exceed 9 µA, ≤9 µA
Tools
Leakage current meter or digital multimeter on µA range

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

AED fails to connect to analyzer

QUIK-COMBO cable not properly seated or defective

Ranked causes

  1. 1. QUIK-COMBO test post adapter not connected (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Analyze LIFEPAK menu access

Menu navigation to adjust or verify defibrillator calibration settings

Ranked causes

  1. 1. Menu system access needed for parameter adjustment (unknown)
First check

Confirm ANALYZE MENU key accessibility

Test point
LIFEPAK 500 keypad
Expected
Menu system responds to key press

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Auto battery test disabled patient safety

Automatic battery self-test mode is not enabled; unit cannot perform ongoing battery monitoring

Ranked causes

  1. 1. Auto battery test mode set to OFF (common)
First check

Verify auto battery test mode setting

Test point
Service Mode menu
Expected
AUTO BATTERY TEST mode is ON

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Automatic advisory operation failed patient safety

AED does not complete automatic advisory operation diagnostic tests; CPR coaching or shock advisory may be non-functional

Ranked causes

  1. 1. Advisory algorithm or analysis circuit failure (unknown)
First check

Verify automatic advisory operation test completion

Test point
AED analysis and advice module
Expected
AED completes all automatic advisory operation tests

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Automatic advisory operation fails patient safety

AED does not complete automatic advisory operation tests correctly

Ranked causes

  1. 1. Software or processing circuit fault (occasional)
First check

Run automatic advisory operation diagnostic

Test point
Service Mode diagnostic menu
Expected
AED completes all automatic advisory operation tests without error

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Automatic test results fail patient safety

One or more automatic tests display failure instead of PASS in the Automatic Test Results window

Ranked causes

  1. 1. Test execution error or equipment malfunction (unknown)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Battery auto-test disabled patient safety

AUTO BATTERY TEST mode is not enabled

Ranked causes

  1. 1. Auto battery test setting disabled in software (occasional)
First check

Verify AUTO BATTERY TEST mode setting

Test point
Service Mode menu
Expected
AUTO BATTERY TEST mode is set to ON

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Battery cartridge leaking or defective caution

Battery shows signs of leakage or does not function

Ranked causes

  1. 1. Battery cartridge defective (unknown)

Battery charger voltage out of specification

Battery charger output voltage is outside 9.78–10.00 V range; charger or power supply defective

Ranked causes

  1. 1. Battery charger circuit degradation or external power supply failure (occasional)
First check

Measure battery charger output voltage

Test point
Charger output connector
Expected
9.78 to 10.00 volts, 9.78–10.00 V
Tools
Digital multimeter

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Battery connection fault

Battery not detected or connection issue

Ranked causes

  1. 1. Battery connector disconnected or loose (common)
First check

Check battery connector seated properly on Main PCW

Test point
Battery connector
Expected
Connector fully inserted and secure

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Battery error patient safety

Battery-related fault or alarm condition

Ranked causes

  1. 1. Low battery voltage (common)
First check

Check battery voltage

Test point
Battery terminals
Expected
Nominal voltage for battery type

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Battery polarity incorrect caution

Battery installed with reversed polarity

Ranked causes

  1. 1. Battery installed backward (occasional)
First check

Verify battery polarity matches markings

Test point
Battery compartment
Expected
Positive and negative terminals aligned correctly

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Battery voltage low or absent

Battery voltage reading below expected level

Ranked causes

  1. 1. Battery depleted or defective (common)
First check

Measure battery voltage

Test point
Battery terminals
Expected
Within specification per battery type

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Cables, connectors, or electrodes physically damaged patient safety

Visual or physical inspection reveals cracks, corrosion, loose connections, frayed wires, or other damage to cables, connectors, or electrode pads

Ranked causes

  1. 1. Mechanical wear, environmental exposure, or manufacturing defect (common)
First check

Visual and tactile inspection of cables, connectors, electrodes

Test point
Entire cable assembly and electrode pads
Expected
No visible cracks, corrosion, fraying, or loose connections

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: Battery resistance check

Measure resistance of negative battery terminal to verify battery condition and connector integrity

Ranked causes

  1. 1. Excessive battery or connector resistance (unknown)
First check

Measure resistance from negative battery terminal to Sternum Output Pin 1

Test point
negative battery terminal to Pin 1 (patient connector)
Expected
less than 8 Ω, < 8 Ω
Tools
DMM

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: Defibrillation output energy measurement high voltage

Measure defibrillation output energy using LIFEPAK energy meter connected to analyzer

Ranked causes

  1. 1. AED must be in Clinical mode for defibrillation measurement (common)
First check

Place AED in Clinical mode

Test point
AED control panel
Expected
AED in Clinical mode

1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: Energy output patient safety

Verification that the defibrillator energy output meets specified performance within acceptable tolerance

Ranked causes

  1. 1. Energy calibration required (unknown)
First check

Set defibrillation analysis mode to ENERGY

Test point
ENERGY selection
Expected
@??? t 1range

6 more checks with pass and fail actions, 6 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: ESD test verification caution

Electrostatic discharge test procedure for LIFEPAK 500 using ESD10 device per IEC 61000-4-2 standard

Ranked causes

  1. 1. ESD immunity verification required (unknown)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: LCD contrast adjustment

Adjustment procedure to set LCD contrast on LIFEPAK 500 AED to optimal display level

Ranked causes

  1. 1. LCD contrast requires calibration (unknown)
First check

Access ADJUST LCD CONTRAST screen

Test point
Service menu
Expected
ADJUST LCD CONTRAST screen displays

3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: LIFEPAK 500 boot test patient safety

Procedure to verify LIFEPAK 500 boots correctly into CONNECT ELECTRODES state after completing TimeOut/Max Battery Recovery procedure

Ranked causes

  1. 1. TimeOut/Max Battery Recovery procedure completion (common)
First check

Insert insulated shunter cable between TR+XX and TR-abb as shown at the left

Test point
TR+XX and TR-abb
Expected
Insulated shunter cable connected

5 more checks with pass and fail actions are in ServiceForge. Connect ServiceForge to your AI

Calibration: LIFEPAK 500 defibrillator analysis function patient safety

Verify ANALYZE button and menu functions for proper operation and device response

Ranked causes

  1. 1. Device ANALYZE function requires calibration verification (unknown)
First check

Power on device in HEART mode

Test point
Power switch
Expected
Device boots to HEART mode

3 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: Oscilloscope defibrillation output high voltage

Set oscilloscope to measure defibrillation energy output with correct settings and energy meter baseline

Ranked causes

  1. 1. Oscilloscope requires proper configuration for energy measurement (common)
First check

Connect oscilloscope to defibrillation analyzer scope output

Test point
scope output connection
Expected
oscilloscope connected

3 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: Performance inspection patient safety

Computer-assisted automated tests for LIFEPAK 500 defibrillator including serial communications, battery sense, slow charge rate, 9 V monitor, motion detection, and PPE self-test functions

Ranked causes

  1. 1. Calibration procedure execution (common)
First check

Serial port communication

Test point
COM1 or COM2
Expected
Unit under test connected to selected serial port

5 more checks with pass and fail actions, 8 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: Performance Inspection Procedure patient safety

Verification of LIFEPAK 500 defibrillator performance by measuring defibrillator impedance readings against specified tolerances using a decade resistance box and VPK-100 test adaptor.

Ranked causes

  1. 1. Routine calibration and performance verification (common)
First check

Press ANALYZE button to initiate impedance measurement

Test point
ANALYZE button
Expected
Initiate Part A impedance test

3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: Performance Inspection Procedure - Fail condition patient safety

Action required when impedance measurements are outside specified tolerances.

Ranked causes

  1. 1. Impedance measurement outside tolerance (rare)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Calibration: remaining energy levels patient safety

Verify remaining energy levels on display are within acceptable output ranges for monophasic and biphasic LIFEPAK 500 defibrillators

Ranked causes

  1. 1. Energy level output verification required (unknown)
First check

Verify monophasic AED remaining energy output

Test point
LIFEPAK 500 Monophasic AED display
Expected
200 ± and 360 ±

1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Computer assisted tests fail caution

AED fails computer-assisted diagnostic tests in Service Mode

Ranked causes

  1. 1. Internal fault in tested circuit or software error (occasional)
First check

Execute computer-assisted test suite in Service Mode

Test point
Service Mode test menu
Expected
All computer-assisted tests pass without errors

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Computer-assisted tests failed

AED does not pass computer-assisted diagnostic tests; internal system fault detected

Ranked causes

  1. 1. Microprocessor, memory, or internal system fault (unknown)
First check

Run computer-assisted diagnostic test suite

Test point
AED microprocessor and internal circuits
Expected
All computer-assisted tests pass

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Data or memory issue

Device memory or stored data error

Ranked causes

  1. 1. Data corruption in memory (rare)
First check

Test memory integrity

Test point
Device memory
Expected
No error codes or CRC failures

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Data save not completed patient safety

Device powers up but data save operation did not complete

Ranked causes

  1. 1. Data save operation failed (unknown)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Date or time incorrect

AED internal clock displays wrong date or time after self-test

Ranked causes

  1. 1. Battery-backed real-time clock failure or user error during setup (occasional)
First check

Verify time and date display

Test point
AED display after self-test
Expected
Current date and time displayed correctly

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Device selected to wrong mode patient safety

Unit operating in incorrect mode or configuration

Ranked causes

  1. 1. Mode switch set incorrectly (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Electrode impedance test failure

AED does not respond properly to electrode impedance measurement tests; may indicate electrode or sensing circuit defect

Ranked causes

  1. 1. Defective electrodes or impedance sensing circuit (unknown)
First check

Verify electrode impedance test response

Test point
Electrode connectors
Expected
AED properly responds to impedance tests

1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Energy output out of specification patient safety

Actual delivered energy does not match nominal specification or tolerance range for any shock energy level

Ranked causes

  1. 1. High-voltage supply, charging circuit, or capacitor degradation (unknown)
First check

Measure shock energy at each level

Test point
Defibrillator analyzer input
Expected
Monophasic: 200 J (190–210), 300 J (285–315), 360 J (342–378); Biphasic: 100 J (95–105), 360 J (342–378)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Error message or alarm code displayed patient safety

Device displays error or alarm notification to operator

Ranked causes

  1. 1. Internal device error or alarm condition (unknown)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Fault code does not clear after restart patient safety

Fault code persists in Fault Code Log after shutdown and restart of the AED, indicating possible permanent hardware error or recurring transient interference.

Ranked causes

  1. 1. Permanent hardware failure (rare)
First check

Verify fault code persists after two restart cycles

Test point
Fault Code Log
Expected
Same fault code recorded after restart; does not clear

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Improved power on sequence

Device powers on in unexpected sequence or manner

Ranked causes

  1. 1. Dime-of-Way clock battery defect (rare)
First check

Verify Main PCW installation and operation

Test point
Main PCW
Expected
PCW installed and functioning properly

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Incorrect time or date display caution

AED displays wrong time and date values

Ranked causes

  1. 1. Real-time clock battery depleted or circuit failure (occasional)
First check

Verify displayed time and date are correct

Test point
AED display screen
Expected
Time and date match current values

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Keyboard does not respond caution

AED fails to enter Service Mode when keyboard is tested

Ranked causes

  1. 1. Keyboard membrane or circuit failure (occasional)
First check

Attempt keyboard test in Service Mode

Test point
Keyboard input
Expected
AED successfully enters Service Mode

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Keypad test failed

Keypad does not respond to input or shows error during test

Ranked causes

  1. 1. Key switch caps loose or damaged (occasional)
First check

Verify keypad overlay is properly installed

Test point
Top cover keypad area
Expected
Cover properly installed and secure

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Leakage current exceeds limit high voltage

Lead-to-lead leakage current exceeds 9 µA; electrical safety hazard to patient or operator

Ranked causes

  1. 1. Insulation breakdown or contamination on PCB or connectors (rare)
First check

Measure lead-to-lead leakage current

Test point
Electrode connectors or internal test points
Expected
Leakage current ≤9 µA, ≤9 µA
Tools
Medical-grade leakage current meter

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Main CPU error

Main CPU fault code detected during self-test

Ranked causes

  1. 1. Defective Main CPU (rare)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Pad or electrode issue patient safety

Problem with defibrillator pads or electrodes

Ranked causes

  1. 1. Pads expired or defective (common)
First check

Verify pad expiration date

Test point
Pad package
Expected
Current date before expiration

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Performance Inspection patient safety

Verify LIFEPAK 500 AED functions correctly through systematic checks of power, indicators, and button operation

Ranked causes

  1. 1. Unit requires periodic performance verification (common)
First check

Power on the LIFEPAK 500 AED

Test point
ON/OFF pad
Expected
Unit powers on

4 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI

More symptoms

  • Power-on sequence incomplete
  • Review fault codes on display
  • Serial number mismatch
  • Service Mode entry failed
  • Shock counter display review
  • Test equipment verification
  • Unit displays ANALYZING NOW—STAND CLEAR
  • Unit displays ANALYZING NOW—STAND CLEAR—NO SHOCK ADVISED—CHECK FOR PULSE
  • Unit displays CONNECT ELECTRODES
  • Unit displays fault code
  • Unit marked as out of use
  • Yellow operating system light on

12 more symptoms with ranked causes and checks are in ServiceForge. Connect ServiceForge to your AI

Error codes

CodeMeaningTriggerSeverity
**??CPU data save volume errorCPU unable to access data volumeerror
**?`CPU measured clock input out of rangeClock frequency outside specificationerror
**?@CPU SV voltage check failedVoltage measurement out of range during testerror
**?>CPU clock usage flag not organizedClock memory structure corruptederror
**?^CPU symbol stored flag high (repeated)Symbol storage flag remains setwarning
**?]CPU symbol two stored flag high (repeated)Secondary symbol flag remains setwarning
**?aCPU symbol two stored flag highSecondary symbol flag set abnormallywarning
**?bCPU symbol stored flag highSymbol storage flag set incorrectlywarning
Battery Low BatteryBattery voltage is low but unit may still operateBattery voltage drops below normal operating levelwarning
Battery Out of ServiceBattery is no longer usable or not installedBattery voltage below threshold or expired battery detectederror
CCC 1Corrective action code indicating first fault routePrimary fault detectionunknown
CCC 2Corrective action code indicating second fault routePrimary fault persists after first remedyunknown
D>?@Data save memory read errorDevice unable to read from data save memoryerror
D>??Data save mount volume errorDevice unable to access data save locationerror
D>?`RAM or long-term battery discrepancyMismatch between RAM and backup battery statuserror
**?dCPU measured alert input out of rangeAlert signal voltage abnormalerror
Data CRC Data Corrupted DataData integrity check failed; memory corruption detectedDevice detects checksum mismatch in stored dataerror
DDMMMYY HH:MMFault code with date and time stampWhen fault codes are present in device memoryunknown
E-.Data memory test zero battery malfunctionBattery test failureerror
E-$Data memory test zero zero battery malfunctionBattery test failureerror
E-^??Control circuit power mismatchControl board voltage regulation out of specificationerror
E-0@.System waveform shape errorOutput waveform deviates from specified shapeerror
E-0@]Device low power, system status conditionBattery or power supply below operating thresholdwarning
E-0@$Device queue buffer overrunData buffer overflow conditionwarning
E-0@^System low amplitude errorOutput signal amplitude below specificationerror
E-0@]System telemetry function errorData transmission or telemetry subsystem failureerror
E-01Loose or incorrect pad applicationPad sensor detects abnormal impedance or contacterror
E-01Connector, battery contacts defectiveBattery contact or connector failure detectederror
E-02Battery signal data corruptedBattery data reading errorerror
E-02Loose or incorrect connectorElectrode connector not fully seated or damagederror
E-03Loose skin electrode, modeElectrode contact lost during operationwarning
E-04Battery rigging to internal power dataBattery rigging configuration errorerror
E-04Loose skin electrode, missing AED connectorElectrode signal intermittent or absenterror
E-05Loose skeletal, to-I, modeSkeletal muscle artifact or motion detectedwarning
E-06Loose heart, mode, off, more, or onElectrode or lead contact problem during operationerror
E-07Loose heart, mode, all 1 st, on or offIntermittent electrode signal during defibrillationerror
E-08Loose heart, receiveElectrode contact lost during analysis phaseerror
E-09Loose E15, do-I, receive, modeE15 sensor or lead contact intermittentwarning
E-0@aSystem address errorMemory or communication address fault detectederror
E-0@bDevice high power, system status conditionBattery or power supply above normal operating thresholdwarning
E-0@ESystem configuration power mismatchConfiguration does not match actual power supplyerror
E-1Unit will not load or power onDevice fails to power upcritical
E-1AED not ready—test abortion detectedSelf-test failurecritical
E-10Loose R15#, mode registered on subsystemR15# sensor reporting abnormal statewarning
E-10Control invalid (I/O E15, I14, HE)Control processing error detectederror
E-10Communication test defibrillator missing successUnit fails communication diagnostic testerror
E101E15 chip malfunctionChip hardware failurecritical
E102E15 chip not readyChip initialization failurecritical
E103E15 chip sample timeout not storedTimeout during samplingerror
E104E15 chip queue full errorQueue overflowerror
E105E15 chip shutdown data corruptedData corruption on shutdowncritical
E106Control circuit current short detected anchorShort circuit detectedcritical
E107Control circuit current short leads conditionShort circuit on leadserror
E108Control circuit current short energy statusEnergy circuit shortcritical
E-11Loose display, reset, modeDisplay firmware or state errorwarning
E-11Startup ROM test failed, ROM not maskedROM integrity check failure during startupcritical
E-11Communication Y defibrillator missing successY-channel communication failureerror
E-12Communication test X defibrillator missing successX-channel communication failureerror
E-12Control invalid, startup data error, data category mismatchStartup configuration data errorerror
E-12Loose axon motor, bank, subsystem, modeMotor control or feedback errorerror
E-13Anomaly in ROM test expiredROM anomaly detection during test sequenceerror
E-13Communication Y X defibrillator missing successDual-channel communication failureerror
E-13Loose extension, to-I, bank, subsystem, modeExtension module connection or control errorwarning
E-14Control invalid, EEPROM abort object, ROM test expiredEEPROM or ROM integrity failurecritical
E-14Loose bus, bank, subsystem, modeInternal bus communication errorerror
E-14Communication test band errorBand frequency communication error detectederror
E-15Communication Y band errorY-band communication frequency errorerror
E-15Startup ROM anomaly offset, EEPROM not maskedROM offset or EEPROM integrity issue during startuperror
E-15Loose monitor, E15, bank, subsystem, modeMonitor module or E15 interface malfunctionerror
E-16Loose electro, bank, subsystem, modeElectrocardiogram processing errorerror
E-16Mohawk band HIS band error at test complex malfunctionHIS band frequency or modulation errorerror
E-16Startup sensor support, EEPROM not maskedSensor configuration or EEPROM error at startuperror
E-17Mohawk HIS complex at Y complex malfunctionHIS-Y complex signal integrity failureerror
E-17Loose control, and, bank, subsystem, modeControl system error or interface failureerror
E-17Startup output signal, data flowfield, ROM not maskedOutput signal or data flow error at startuperror
E-18Loose non, bank, subsystem, modeNon-standard or undefined subsystem errorwarning
E-18Startup clock check, ROM not maskedClock circuit or ROM integrity failureerror
E-18Check FusesFuse integrity diagnostic failurewarning
E-19Startup CPU, ROM not maskedCPU initialization or ROM failurecritical
E-19Check the BatteryBattery diagnostic test failedwarning
E-1b??Analog low voltage malfunctionAnalog circuit supply voltage below minimum thresholdcritical
E-1b?@Non-rank waveform absentExpected waveform signal not detected on reference channelwarning
E-1d?@EEPROM memory not initializedSystem detects uninitialized EEPROM on startuperror
E-1d?`EEPROM code download failedFirmware upload to EEPROM does not complete successfullyerror
E-1d??EEPROM communication checksum failureData read from EEPROM fails checksum validationerror
E-1d?dEEPROM communications bad packet detectedReceived data packet fails integrity checkerror
E-1d?ZEEPROM no data received from timeoutEEPROM communication times out waiting for dataerror
E-2Unit will not charge or battery lowBattery charging failure detectederror
E-20Startup EEPROM, ROM not maskedEEPROM access or ROM integrity failurecritical
E-20Replace battery Time Mask Clock BatteryClock or backup battery depletedwarning
E-21Startup input abort, ROM not maskedInput circuit or ROM failure at startuperror
E-22Startup input anomaly, ROM not maskedInput anomaly detection during startuperror
E-23Startup output abort, ROM not maskedOutput circuit or ROM failure at startuperror
E-24Startup input abort, EEPROM, ROM not maskedInput circuit, EEPROM, or ROM failurecritical
E-25Startup ROM anomaly, ROM not maskedROM anomaly detected at startuperror
E-3Battery is damaged or will not hold chargeBattery fails to maintain chargeerror
E-3AED not ready—dump memory errorMemory dump failedcritical
E-4AED not ready—data memory errorMemory corruptioncritical
E-4User pads, electrodes, energy output unable to dischargeDefibrillation output failurecritical
E-5AED not ready—memory directory system errorDirectory system failurecritical
E-5User pads, therapy button will not dischargeTherapy button fails to trigger dischargeerror
E-6AED not ready—memory data mismatch errorData integrity check failedcritical
E-6User pads, data will not dischargeData transmission failure during dischargewarning
E-7AED not ready—memory directory system errorDirectory malfunctioncritical
E-7User pads, therapy button will not discharge will not dischargeRepeated therapy button discharge failureerror
E-8User pads, capacitor malfunctionCapacitor charging or holding failureerror
E-9Decomfibrillator ECG incomplete at ECG complex malfunctionECG signal acquisition or analysis failureerror
E-^?dControl board signal update timeoutControl signal update cycle exceeds timeout thresholdwarning
EE-01Self-test failed too many timesMultiple consecutive self-test failurescritical
EE-02Self-test abort not insuredAbort safety mechanism failure during self-testcritical
EE-03Self-test runtime assertsRuntime assertion detected during self-testerror
EE-04Non-volatile dropped lead dead messageLead-off signal loss during operationerror
EE-05Non-volatile dropped low battery messageBattery voltage drops unexpectedlyerror
EE-06Non-volatile battery not continualBattery continuity check failureerror
EE-07Incorrect file of waveform data typeWaveform data format error detectedwarning
EE-08Configuration of battery used out of order function messageBattery configuration mismatch detectederror
EE-09Non-verbose dropped lead dead messageLead-off detection during normal operationwarning
EE-10Control voltage jumps startup switch mightControl voltage fluctuation at startuperror
EE-11Control battery high voltageBattery voltage exceeds safe rangecritical
E-^?ZControl board signal output lead status timeoutControl output signal fails to reach expected stateerror
Fault codes stored in Fault Code LogAED has detected and recorded one or more internal faults during self-test or operationInternal self-test program execution or routine AED operationwarning
Pad Battery Out of Service Pad BatteryDefibrillator pads are expired or non-functionalPads beyond expiration date or connection failureerror
S??Unit data save volume errorData volume access failureerror
Sensor Reset EnergySensor or energy measurement system errorDevice cannot measure or reset energy-related sensorserror
System FPGA Firmware Voltage ReferenceInternal system, FPGA, firmware, or voltage reference failureSelf-test detects failure in core system componentcritical
**?ZCPU measured pump input out of rangePump drive signal abnormalerror

Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI

Community

0 fixes logged by technicians through their AI, with outcomes, for this model.

ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.