Philips FM-2: troubleshooting and error codes
The ServiceForge knowledge base holds 7 documented symptoms for the Philips FM-2, with 10 ranked causes, 11 diagnostic checks with test points and expected values, and 36 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
Unit does not power on or display inactive
Display completely dark or very faint; no visible screen output after power applied
Ranked causes
- 1. Display backlight fluorescent tube or high voltage driver failed (common)
- 2. Internal battery exhausted or defective (occasional)
- 3. Monitor power supply or internal electronics failure (occasional)
Examine display in dim ambient light
- Test point
- Display face
- Expected
- Faint outline visible if backlight failed only
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Monitor fails power-on self-test patient safety
Error screen displayed during startup; all monitoring functions disabled; error number logged in error log
Ranked causes
- 1. Program checksum failure during RAM load (unknown)
- 2. Watchdog timer failure (unknown)
Press On/Off button and observe startup sequence
- Test point
- LCD screen and audio output
- Expected
- LCD illuminates blank; two-tone jingle plays; startup screen with Agilent logo, bootcode version, application version displayed
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Battery depleted or faulty caution
Monitor battery does not hold charge, fails self-test, or does not power unit during cordless operation
Ranked causes
- 1. Battery depleted or not charged (common)
Verify battery charge state before testing
- Test point
- Battery indicator or charge status display
- Expected
- Battery fully charged or at acceptable level per manual
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Monitor and accessory damage patient safety
Visual inspection for damage to monitor body, cables, line cords, transducers, instruments that may affect patient safety or performance
Ranked causes
- 1. Physical damage from handling, impact, or wear (occasional)
Visual inspection of monitor enclosure
- Test point
- Monitor body exterior
- Expected
- No cracks, dents, burns, discoloration, or physical damage
2 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Monitor displays error screen and sounds tone patient safety
Display shows error condition, audible error tone sounds, and all monitoring functions stop
Ranked causes
- 1. Self-detectable error condition (unknown)
Observe error screen display
- Test point
- Monitor display
- Expected
- Error screen displayed
2 more checks with pass and fail actions are in ServiceForge. Connect ServiceForge to your AI
Monitor shuts down without warning on undetected error patient safety
Operational error not self-detected by monitor; unit shuts down with no audible or visual warnings or indicators
Ranked causes
- 1. Undetected operational error (unknown)
Monitoring display degraded or unreliable patient safety
Display shows artifacts, gaps, or poor quality; FHR(s) or TOCO values appear unreasonable after successful power-up and self-test
Ranked causes
- 1. Defective or worn transducer (common)
Examine display after power-up and self-test
- Test point
- Display screen
- Expected
- Clear, artifact-free display with reasonable FHR and TOCO values
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Error codes
| Code | Meaning | Trigger | Severity |
|---|---|---|---|
1 | Monitor memory corrupted | Memory integrity check failure | critical |
10 | Voltage out of range | Power supply voltage outside acceptable limits | error |
11 | Watchdog timer not functioning | Watchdog timer hardware failure | critical |
12 | System received too many resets | Excessive reset events detected | critical |
13 | Recorder software incompatible with monitor | Version mismatch between monitor and recorder | error |
14 | Flash memory type incompatible with software | Flash memory type mismatch | error |
15 | Phase lock loop lost lock (non-critical) | PLL synchronization loss | info |
16 | Failed to allocate requested memory | Memory allocation failure | critical |
17 | Problem with codec detected | Codec hardware or driver failure | error |
18 | High half-word of flash failed to program | Flash programming error | critical |
19 | Low half-word of flash failed to program | Flash programming error | critical |
1xx | Algorithm errors | Fetal monitoring algorithm failure | error |
2 | Invalid internal software state | Software state machine failure | error |
20 | High half-word of flash failed to verify | Flash verification error | critical |
21 | Low half-word of flash failed to verify | Flash verification error | critical |
2xx | Printer errors | Printer system failure | error |
3 | Unable to acquire software resource | Queue or semaphore allocation failure | error |
30 | Error in communications microcontroller | Communications MCU failure | error |
3xx | Fatal operating system errors | OS system failure | critical |
4 | Stack overflow | Stack memory exhausted | critical |
4xx | Fatal processor exceptions | CPU exception or fault | critical |
5 | Bad parameter value passed to function | Function parameter validation failure | error |
50 | Corrupt patient record (trend file) | Patient trend file integrity check failure | error |
51 | Corrupt file system | File system structure failure | error |
52 | Attempt to read deleted file | Read operation on deleted file | error |
53 | File system wrapped memory | File system memory wrap-around | error |
54 | Attempt to read corrupt file | Read operation on corrupted file | error |
55 | Failed to create file | File creation failure | error |
6 | Software in unexpected state | State machine error | error |
7 | Software assertion failed (coding error) | Internal assertion check failure | error |
70 | File corrupted - FM-2 viewer communication error | Communication error during FM-2 viewer data transfer | error |
71 | Invalid patient ID - FM-2 viewer communication error | Patient ID validation failure during data transfer | error |
72 | Invalid sequence number - FM-2 viewer communication error | Sequence number mismatch during data transfer | error |
73 | Remote error - FM-2 viewer communication error | Error message from FM-2 viewer system | error |
8 | Task watchdog timer check-in failure | Task did not respond to watchdog timer | error |
9 | Software CRC in memory invalid | CRC verification failure | critical |
Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI