Philips Avalon FM40: troubleshooting and error codes
The ServiceForge knowledge base holds 60 documented symptoms for the Philips Avalon FM40, with 135 ranked causes, 31 diagnostic checks with test points and expected values, and 0 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
External device not receiving data via LAN/RS232
External surveillance system or device does not receive exported data from monitor
Ranked causes
- 1. LAN/RS232 port not configured for data export (common)
- 2. Cable not connected correctly or defective (common)
- 3. External device does not support protocol version (occasional)
- 4. Terminal concentrator does not support dynamic speed negotiation (rare)
- 5. LAN/RS232 board in wrong slot (occasional)
- 6. LAN/RS232 board defective (rare)
- 7. Wrong cable for RS232 connection (occasional)
7 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
External device not receiving data via MIB/RS232
External device does not receive exported data from monitor via MIB/RS232 interface
Ranked causes
- 1. MIB/RS232 port not configured for data export (common)
- 2. Wrong data export protocol driver configured (common)
- 3. Cable not connected correctly or defective (common)
- 4. External device does not support protocol version (occasional)
- 5. Terminal concentrator does not support dynamic speed negotiation (rare)
- 6. MIB/RS232 board in wrong slot (occasional)
- 7. MIB/RS232 board or connector board defective (rare)
7 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
INOP Check Paper message displayed
Check paper error message displayed by recorder
Ranked causes
- 1. Drawer open with paper on sensor (common)
- 2. Paper jam (common)
- 3. Paper sensor dirty (occasional)
- 4. Paper sensor defective (rare)
- 5. Rubber roller slipping (occasional)
- 6. Non-approved paper loaded (occasional)
- 7. Inadequate contrast or no paper marks (occasional)
7 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Display is blank or brightness reduced
Screen shows no image or reduced brightness after boot phase completes
Ranked causes
- 1. Display flex cable not connected properly (common)
- 2. Back-light inverter cable not connected properly (occasional)
- 3. Back-light tubes defective (occasional)
- 4. Back-light inverter defective (rare)
- 5. LCD flat panel defective (rare)
- 6. API board defective (rare)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Touchscreen not functioning
Touchscreen does not respond to touch input
Ranked causes
- 1. Touchscreen functionality temporarily disabled (common)
- 2. Touch screen cable not connected (occasional)
- 3. Touch controller defective (occasional)
- 4. Touch Sensor defective (occasional)
- 5. Touch calibration problem (occasional)
Check for padlock symbol on Main Screen
- Test point
- Main Screen key
- Expected
- No padlock symbol visible
1 more check with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Transducer Finder LED does not light up
Transducer is plugged in but Finder LED does not illuminate and transducer not working.
Ranked causes
- 1. INOP Bus Master Malfunc displayed - transducer cable defective (common)
- 2. Connector block is defective (occasional)
- 3. Transducer or connector block defective (occasional)
- 4. API board is defective (occasional)
- 5. No power to API board (rare)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Unit does not power on
Green LED does not light, no test tone heard from speaker
Ranked causes
- 1. No AC mains connection (common)
- 2. Power supply defective (occasional)
- 3. Switch board cable disconnected or loose (occasional)
- 4. Switch board defective (occasional)
- 5. API board defective (rare)
Verify AC mains connection
- Test point
- Power cord and AC outlet
- Expected
- Power cord firmly connected to powered AC outlet
2 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Keyboard or Mouse not functioning
Keyboard or mouse attached directly to monitor are not responding.
Ranked causes
- 1. Keyboard/Mouse not connected properly (common)
- 2. Keyboard/Mouse are defective (occasional)
- 3. USB/PS/2 I/O board not properly plugged in (occasional)
- 4. USB/PS/2 I/O board is defective (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
No recorder key available and INOP FetRec Equip Malf displayed
Recorder control unavailable on screen with equipment malfunction message
Ranked causes
- 1. Recorder not calibrated (common)
- 2. EEPROM on API board defective (rare)
- 3. Recorder controller on API board defective (rare)
- 4. Recorder cable disconnected (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Paper empty warning issued but paper not out
Warning displayed at bottom of screen indicating paper empty but paper is actually loaded
Ranked causes
- 1. Drawer open or not properly closed (common)
- 2. Paper jam (common)
- 3. Paper sensor disconnected (occasional)
- 4. Paper sensor defective (rare)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Paper not transporting
Paper does not move or advance through the recorder mechanism
Ranked causes
- 1. Drawer open or not properly closed (common)
- 2. Paper jam (common)
- 3. Stepper motor cable disconnected (occasional)
- 4. Stepper motor defective (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Alarm sounds not issued despite alarm condition patient safety
Alarm activates but no audible sound is produced from the speaker
Ranked causes
- 1. Monitor volume set to 0 (common)
- 2. Speaker defective (occasional)
- 3. Sound amplifier on API board defective (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Monitor alarmed but Nurse Call not activated patient safety
Monitor alarm triggered but nurse call relay does not activate.
Ranked causes
- 1. Incorrect relay configuration (latency, trigger) (common)
- 2. Cable connection defective to monitor or nurse call system (occasional)
- 3. Flexible Nurse Call Relay I/O board is defective (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
No test sound or Speaker Malfunct INOP
Speaker does not produce test tone during boot or INOP Speaker Malfunct message displayed
Ranked causes
- 1. Speaker cable disconnected (common)
- 2. Speaker defective (occasional)
- 3. API board defective (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Paper remains blank despite normal recorder operation
Recorder runs normally but printhead does not print on paper
Ranked causes
- 1. Thermal printhead disconnected (occasional)
- 2. Thermal printhead defective (rare)
- 3. Wrong side of paper facing up (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Remote touch display not responding via MIB/RS232
Connected remote display does not respond to touch input or control signals
Ranked causes
- 1. Cable not properly connected (common)
- 2. MIB/RS232 port not configured (common)
- 3. Factory defaults loaded (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Settings Malfunct INOP message displayed
Settings Malfunct message appears on screen indicating configuration or memory corruption
Ranked causes
- 1. Problem during configuration cloning process (occasional)
- 2. Settings memory space corrupted (occasional)
- 3. Main CPU board defective (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Speaker Malfunct INOP message displayed
INOP Message Speaker Malfunct appears on screen indicating speaker or amplifier failure
Ranked causes
- 1. Speaker cable disconnected (common)
- 2. Speaker defective (occasional)
- 3. Sound amplifier on API board defective (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Trace has poor print quality
Recorded trace output has degraded or inadequate print quality
Ranked causes
- 1. Heat setting needs adjustment (common)
- 2. Thermal printhead dirty (common)
- 3. Thermal printhead failure (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
API Board LED behavior abnormal caution
LEDs on API board are not blinking as expected.
Ranked causes
- 1. LEDs off - power supply or API board issue (occasional)
- 2. LEDs on continuously - API board defective (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Tympanic Temperature patient safety
Periodic calibration of temperature measurement sensor to maintain accuracy. Required after environmental exposure or physical damage.
Ranked causes
- 1. Annual preventive maintenance interval (common)
- 2. Unit dropped, damaged, or stored at extreme temperature (occasional)
Determine if calibration needed
- Test point
- Tympanic temperature module
- Expected
- Unit not dropped/damaged and storage temperature -25ºC to 55ºC OR annual interval reached
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Check Monitor Func INOP
INOP message indicates problem with monitor voltages or internal temperature
Ranked causes
- 1. Problem with voltages (5V) in monitor (common)
- 2. Temperature inside monitor too high (common)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Check Settings INOP
INOP occurs during normal operation indicating possible monitor software problem
Ranked causes
- 1. Monitor software problem (unknown)
- 2. Incomplete or unsuccessful software upgrade (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Green LED does not blink after power on
Power switch activated but green LED does not blink during boot phase
Ranked causes
- 1. Switch board defective (common)
- 2. CPU processor on API board defective (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Individual Parameter INOP patient safety
Parameter-specific INOP messages for individual equipment modules (FHR, NBP, SpO2, Toco, etc.)
Ranked causes
- 1. Defective transducer, sensor, patient module, or board (common)
- 2. Incompatible API Board firmware with new software (Bus Master Malfunc only) (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
No video on remote display
Connected remote display shows no video output.
Ranked causes
- 1. Video cable not properly connected (common)
- 2. Remote display has no power (common)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Paper not feeding properly
Paper does not advance smoothly through the recorder
Ranked causes
- 1. Paper loaded incorrectly (common)
- 2. Rubber roller dirty (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Trace not printed correctly aligned with paper gridlines
Recorded trace vertical alignment does not match paper grid references
Ranked causes
- 1. Offset needs adjustment (common)
- 2. Wrong paper scale being used (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Transducer connected with INOP Bus Master Malfunc displayed
Transducer is plugged in and connected but INOP Bus Master Malfunc message appears.
Ranked causes
- 1. API board is defective (occasional)
- 2. Transducer is defective (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Tympanic Thermometer does not function
Thermometer is not operating or responding.
Ranked causes
- 1. No connection between base station and thermometer or monitor (common)
- 2. Thermometer is defective (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
USB-connected devices not functioning
None of the connected devices via USB port are working.
Ranked causes
- 1. USB port in monitor is defective (occasional)
- 2. Invalid device combination or defective connected devices (common)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
All transducers (US, Toco, IUP, ECG) do not work
None of the transducers are functioning.
Ranked causes
- 1. INOP Bus Master Malfunc displayed - API board is defective (occasional)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Bad or distorted printout in first 1 cm of trace
Poor quality print or distortion at the beginning of the recorded trace
Ranked causes
- 1. Paper drawer not fully closed before recording (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Noninvasive Blood Pressure patient safety
Periodic calibration of blood pressure measurement module to maintain accuracy and safety compliance
Ranked causes
- 1. Scheduled preventive maintenance interval (common)
Perform calibration per schedule
- Test point
- NBP module
- Expected
- Calibration completed per local requirements
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Transducer belt button replacement caution
Removal and installation of belt button on transducer
Ranked causes
- 1. Belt button requires replacement or is broken (unknown)
Remove old belt button using supplied tool
- Test point
- Belt button attachment point on transducer
- Expected
- Belt button removed without damage to threaded insert
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Transducer cable exchange
Replacement of transducer cable assembly with proper gasket and cover reinstallation
Ranked causes
- 1. Transducer cable requires replacement (unknown)
Pierce and remove screw cover without damaging top cover
- Test point
- Three screw cover locations on transducer frame
- Expected
- Screw cover removed without damage to transducer top cover
4 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Check Nurse Call Relay INOP message issued caution
Monitor displays INOP message regarding Flexible Nurse Call Relay.
Ranked causes
- 1. Flexible Nurse Call Relay I/O board is defective (occasional)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Check TI Config INOP
INOP occurs after software upgrade or option change regarding NST Report settings
Ranked causes
- 1. NST Report Guideline not set after software upgrade (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cyclic reboot loop
Monitor attempts to boot, power fails, LED blinks, display briefly shows then goes dark, LED stays lit, cycle repeats
Ranked causes
- 1. Hardware failure caused by short circuit, likely defective NBP board (common)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
INOP FetRec Chk Config message displayed
Configuration check error message displayed for recorder settings
Ranked causes
- 1. Recorder Speed and/or Scale Type not configured (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
INOP Printhead Overheat message displayed caution
Printhead overheat error message displayed
Ranked causes
- 1. Printhead temperature too high (occasional)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
INOP Wrong Paper Scale message displayed
Wrong paper scale error message displayed
Ranked causes
- 1. Wrong scale paper loaded (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Installation: Monitor with non-medical device on same outlet caution
Installation of monitor connected to same electrical outlet as non-medical equipment
Ranked causes
- 1. Installation configuration creates potential interference or safety concern (occasional)
Visual inspection
- Test point
- Monitor and cables
- Expected
- No damage or defects
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Installation: Monitor with Philips medical display caution
Installation of monitor with Philips-specified medical display connected
Ranked causes
- 1. Installation configuration requires testing (common)
Visual inspection
- Test point
- Monitor, display, and interconnecting cables
- Expected
- No damage or defects
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Installation: Standalone monitor with no external display caution
Installation of monitor as standalone unit with video output connected but no display attached
Ranked causes
- 1. Installation configuration requires limited testing (occasional)
Visual inspection
- Test point
- Monitor and cables
- Expected
- No damage or defects
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Internal.Comm.Malf INOP
Internal communication malfunction INOP message
Ranked causes
- 1. Main CPU board defective (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Maintenance: Recorder printout degraded caution
Recorder produces faded, unclear, or poor quality thermal paper output
Ranked causes
- 1. Degraded recorder output quality (occasional)
Inspect recorder output quality
- Test point
- Printer thermal head and paper path
- Expected
- Clear, legible printout at standard darkness
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Temperature reading unusually high patient safety
Thermometer displays abnormally high temperature value.
Ranked causes
- 1. Probe cover is damaged or not attached correctly (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Temperature reading unusually low patient safety
Thermometer displays abnormally low temperature value.
Ranked causes
- 1. Probe, probe cover, or ear canal obstructed (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Testing: Electrical safety after service high voltage
Verify protective earth resistance and leakage currents after maintenance or repairs
Ranked causes
- 1. Safety test required after power supply repair or component replacement (common)
Measure protective earth resistance
- Test point
- Protective earth connection
- Expected
- Per IEC 60601-1 specification
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Testing: Noninvasive Blood Pressure performance patient safety
Performance verification of blood pressure measurement module against known standards
Ranked causes
- 1. Scheduled performance assurance interval or suspected measurement error (common)
Verify NBP measurements against reference standard
- Test point
- NBP module
- Expected
- Measurements within specified tolerance of reference
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Testing: SpO2 performance patient safety
Performance verification of pulse oximetry measurement module
Ranked causes
- 1. Performance assurance testing required (unknown)
Verify SpO2 module measurements
- Test point
- SpO2 sensor and module
- Expected
- Readings within specification per Testing Sequence
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Testing: System test patient safety
Comprehensive functional and safety system test after installation or as part of scheduled maintenance
Ranked causes
- 1. Installation or scheduled maintenance interval (common)
Execute system test per Testing Sequence
- Test point
- Monitor and all connected modules
- Expected
- All tests pass per specification
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Testing: Transducers and patient modules patient safety
Periodic verification that transducers and patient modules provide correct measurements
Ranked causes
- 1. Annual preventive maintenance interval or suspected measurement error (common)
Verify transducers and patient modules function correctly
- Test point
- All transducers and patient module connectors
- Expected
- Measurements match expected values per Testing Sequence
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Testing: Visual inspection caution
Pre-use visual check for physical damage or defects before each use
Ranked causes
- 1. Pre-use safety check required (common)
Visually inspect monitor condition
- Test point
- Entire unit exterior and connectors
- Expected
- No damage, cracks, or loose components visible
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Transducer belt button is broken or damaged caution
Transducer belt button is mechanically damaged.
Ranked causes
- 1. Mechanical damage to belt button (occasional)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Transducer Finder LED lights briefly then INOP Bus Master Malfunc displayed
Transducer Finder LED lights briefly after plugging in but INOP Bus Master Malfunc message appears and transducer not working.
Ranked causes
- 1. Transducer is defective (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Transducer Finder LED lights briefly, no parameters on screen
Transducer Finder LED lights briefly after plugging in but transducer is not recognized and no parameters displayed.
Ranked causes
- 1. INOP Bus Master Malfunc displayed - transducer is defective (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Unknown transducer connected message after software upgrade
After transducer software upgrade, message 'Unknown transducer connected' appears at screen bottom.
Ranked causes
- 1. Transducer in boot mode and not recognized by monitor (occasional)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Unknown transducer connected message without software upgrade
Message 'Unknown transducer connected' appears at screen bottom without preceding software upgrade.
Ranked causes
- 1. Transducer is defective (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI