Invivo 865214: troubleshooting and error codes
The ServiceForge knowledge base holds 40 documented symptoms for the Invivo 865214, with 56 ranked causes, 119 diagnostic checks with test points and expected values, and 1 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
Battery not holding charge or reduced runtime
Battery powers equipment for significantly shorter duration than normal operation
Ranked causes
- 1. Battery life expired (common)
- 2. Battery dirty terminals (occasional)
- 3. Reduced runtime during active monitoring (common)
Inspect battery terminals for dirt or corrosion
- Test point
- Battery connector terminals
- Expected
- Clean, dry terminals without visible dirt or oxidation
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cart pulled toward MR system by magnetic field MRI environment
Expression MRI Patient Monitoring System Cart experiences magnetically induced pull force toward MR bore face during operation in MR system room
Ranked causes
- 1. Cart positioned inside 5,000 Gauss (0.5T) field line of MR system (common)
- 2. Wheel locks not engaged when cart in MR system room (common)
- 3. Field strength variations or future system enhancements affecting local field distribution (occasional)
Verify cart position relative to MR bore center line
- Test point
- 5,000 Gauss field line boundary
- Expected
- At or outside 5,000 Gauss (0.5T) field line
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Agents flow measurement out of specification
Gas flow rate does not match expected values during flow verification test for adult, neonatal, and water trap configurations
Ranked causes
- 1. Gas sample line blocked, water trap saturated, or pump failure (common)
- 2. Flowmeter calibration error or incorrect setup (occasional)
Enable AGENTS and set PATIENT mode to ADULT
- Test point
- DCU SETUPS / PARAMETER SELECTION menu
- Expected
- AGENTS turned ON, PATIENT set to ADULT
13 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DCU ferrous material attraction in MRI field MRI environment
DCU containing ferrous materials may be attracted to MR magnetic field, causing patient or user injury during installation or removal near the bore
Ranked causes
- 1. DCU positioned within 1,000 Gauss (0.1 T) field line during installation or removal (common)
- 2. Removing DCU too close to MR system magnetic field (common)
Verify DCU installation location distance from MR bore center
- Test point
- MR system center line
- Expected
- At least 1,000 Gauss (0.1 T) field line distance
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
ETCO2 zero calibration or flow measurement error
ETCO2 module does not display zero calibration message during startup or flow rate out of specification after water trap installation
Ranked causes
- 1. ETCO2 module warm-up incomplete or sensor miscalibrated (common)
- 2. ETCO2 sample line flow restriction or water trap blockage (occasional)
Enable ETCO2 in SETUPS/PARAMETER SELECTION menu
- Test point
- DCU parameter selection menu
- Expected
- ETCO2 turned ON
5 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
NIBP adult cuff inflation/deflation abnormal patient safety
Cuff fails to inflate to expected pressure range or does not deflate properly after measurement completion
Ranked causes
- 1. NIBP cuff disconnected, blocked, or pump failure (common)
- 2. Blood pressure algorithm failure to detect measurement endpoint (occasional)
Connect adult cuff around arm
- Test point
- NIBP cuff placement
- Expected
- Cuff snug around arm, no air leaks
4 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
NIBP overpressure detection failure (adult mode) patient safety
System does not detect overpressure condition or does not display OVER PRES message when excessive pressure applied
Ranked causes
- 1. Overpressure relief valve stuck or malfunctioning (common)
- 2. NIBP firmware does not trigger OVER PRES alarm at correct threshold (occasional)
Apply 295 ± 4 mmHg pressure to NIBP pump port (adult)
- Test point
- NIBP Pump (right) port
- Expected
- 295 ± 4 mmHg applied, ±4 mmHg
3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
NIBP overpressure detection failure (neonatal mode) patient safety
System does not detect or signal overpressure condition when excessive pressure applied in neonatal patient mode
Ranked causes
- 1. Neonatal overpressure threshold not calibrated or relief valve failed (common)
- 2. Overpressure alarm delay exceeds 15 second specification (occasional)
Set patient mode to NEO and apply 150 ± 4 mmHg pressure
- Test point
- NIBP Pump (right) port, PATIENT mode set to NEO
- Expected
- 150 ± 4 mmHg applied, ±4 mmHg
5 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
NIBP pneumatic leak test failure patient safety
Pressure difference between peak and final readings not within acceptable range during NIBP cuff inflation and deflation cycles
Ranked causes
- 1. NIBP cuff or hose has internal or external leak (common)
- 2. NIBP pump not holding pressure during test (occasional)
Wrap cuff around fixed object tightly
- Test point
- NIBP cuff
- Expected
- Cuff secured without air gaps
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Power supply not properly positioned for MRI safety MRI environment
Power supply P/N 989803169201 or 989803168201 positioned closer than 10 feet (3 meters) to MR system, risking magnet attraction or interference.
Ranked causes
- 1. Power supply installed too close to MRI magnet (common)
- 2. Grounding integrity compromised by extension cords (occasional)
Measure distance from power supply to MR system
- Test point
- MR system magnet bore
- Expected
- 10 feet (3 meters) or more, minimum
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
SpO2 communication failure with WSPO2 module
Probe status not displayed, missing pulse waveform, or incorrect SpO2 numeric reading when WSPO2 module connected with fiber optic sensor
Ranked causes
- 1. SpO2 probe not inserted correctly or no finger in probe (common)
- 2. SpO2 fiber optic sensor not connected or faulty (occasional)
Enable SpO2 parameter
- Test point
- DCU SETUPS / PARAMETER SELECTION menu
- Expected
- SpO2 enabled
3 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System communication failure between DCU and wireless modules
Icons for DCU, WPU, WECG, and WSPO2 remotes not present on DCU display under various power conditions (DC only, AC with batteries, AC without batteries)
Ranked causes
- 1. Wireless module not powered or battery depleted (common)
- 2. Module communication disabled or not configured (occasional)
Verify wireless module icons displayed on DCU
- Test point
- DCU display
- Expected
- Icons for DCU, WPU, WECG, WSPO2 present
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
System or module power-up failure with AC adapter high voltage
DCU and Cart power indicator LEDs do not illuminate green after AC power applied, indicating no DC power supply output or connection issue
Ranked causes
- 1. AC power cord not connected to mains or power adapter faulty (common)
- 2. DCU or Cart DC input connector not fully seated or contact corrosion (occasional)
Verify AC power cord connected to AC mains outlet
- Test point
- Power adapter AC input
- Expected
- AC power cord (HE02) firmly connected to mains outlet
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
WECG communication failure with patient simulator
No ECG waveform, heart rate tone issues, or incorrect numeric display when WECG module connected to patient simulator
Ranked causes
- 1. WECG leads not properly connected to simulator (common)
- 2. Patient simulator not outputting correct QRS signal (occasional)
Verify WECG lead connections to simulator
- Test point
- Lead wires: GREEN, WHITE, BLACK, RED
- Expected
- Connected per Table 2: GREEN-RL, WHITE-RA, BLACK-LA, RED-LL
4 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Battery exhibits abnormal condition patient safety
Battery shows abnormal heat, odor, color, deformation, puncture, or liquid leakage
Ranked causes
- 1. Battery defect or damage (rare)
Visually inspect battery for abnormal heat, odor, color, deformation, puncture, or leakage
- Test point
- Battery exterior and connector area
- Expected
- Normal appearance: no odor, normal color, no deformation, no visible damage or leakage
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Battery forced into compartment causing damage caution
Physical damage to battery or Expression MRI Patient Monitoring System due to forced battery insertion
Ranked causes
- 1. Excessive force applied during battery installation (occasional)
Verify battery slides smoothly into compartment without resistance
- Test point
- Battery insertion motion
- Expected
- Battery slides smoothly and latches automatically without excessive force
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Battery installation in MR magnetic field MRI environment
Attempt to install or remove ferrous battery within 1,000 Gauss (0.1 T) field line of MR bore centerline
Ranked causes
- 1. Battery attracts to magnetic field causing injury hazard (common)
Confirm PMC/Cart/DCU location relative to MR magnetic field
- Test point
- Distance from MR bore centerline
- Expected
- Unit located outside of 1,000 Gauss (0.1 T) field line
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Battery not latching into compartment
Battery does not automatically latch when inserted into Cart, PMC, or DCU battery compartment despite being fully inserted
Ranked causes
- 1. Battery oriented incorrectly (common)
Verify battery orientation matches device geometry
- Test point
- Battery compartment
- Expected
- Battery contours align with compartment geometry
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cannot safely remove cart stuck to MR system by magnetic field MRI environment
Cart magnetically adhered to MR bore face and operator unable to safely dislodge equipment
Ranked causes
- 1. Improper extraction technique causing vertical MR pull force concentration at base (common)
Identify correct dislodging point on cart structure
- Test point
- Cart base lowest point vs. DCU/guide handle locations
- Expected
- Technician ready to pull only from base at lowest point of system
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
CO2 gas detection measurement error
System does not detect or measure CO2 gas correctly when 10% (76 mmHg) CO2 applied; respiration count exceeds specification during gas flow
Ranked causes
- 1. CO2 sensor contaminated, expired, or miscalibrated (common)
Apply 10% (76 mmHg) CO2 gas to agents inlet
- Test point
- Agents CO2 input port
- Expected
- 10% CO2 gas (76 mmHg equivalent) flowing into system
3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
CO2 occlusion not displayed patient safety
Message 'CO2 OCCLUSION' does not appear on screen within expected time frame
Ranked causes
- 1. CO2 detection system malfunction (unknown)
Verify CO2 occlusion message display
- Test point
- DCU display
- Expected
- CO2 OCCLUSION message appears
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DCU damage from AC mains connection while docked to Cart caution
Damage to DCU or power cable may result if DCU is docked to Cart while still connected to AC mains power
Ranked causes
- 1. Docking DCU to Cart while AC mains power cable connected (occasional)
Verify AC power disconnection before docking
- Test point
- Power cable connection status
- Expected
- AC power cord unplugged from outlet or power converter
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
DCU Power Converter Kit magnetic hazard in MR system room MRI environment
DCU Power Converter Kit is magnetic and will be pulled into MR system if brought into MR system room, creating safety hazard
Ranked causes
- 1. DCU Power Converter Kit (P/N 453564123631) brought into or used in MR system room (occasional)
Verify DCU Power Converter location prior to use
- Test point
- Installation location
- Expected
- MR control room or holding area only, not MR system room
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
DCU printer malfunction near MR magnetic field caution
DCU printer may fail to operate or be damaged if DCU moved too close to 1,000 Gauss (0.1 T) field line
Ranked causes
- 1. DCU with printer option positioned closer than 1,000 Gauss (0.1 T) field line in MR system room (occasional)
Verify DCU with printer location distance from MR bore
- Test point
- MR system center line
- Expected
- At or outside 1,000 Gauss (0.1 T) field line
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
DCU without printer exceeds safe MR field proximity caution
DCU without printer option may be damaged or fail to operate if positioned closer than 5,000 Gauss (0.5 T) field line
Ranked causes
- 1. DCU without printer positioned closer than 5,000 Gauss (0.5 T) field line (occasional)
Verify DCU without printer location distance from MR bore
- Test point
- MR system center line
- Expected
- At or outside 5,000 Gauss (0.5 T) field line
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Initial battery charge insufficient for operation
Batteries not fully charged and conditioned before first use, resulting in reduced operating time
Ranked causes
- 1. Battery not charged 12 hours before first use (common)
Verify initial battery charging was performed for 12+ hours
- Test point
- Battery charge history
- Expected
- All batteries charged minimum 12 hours at AC power with Expression off before first use
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Invasive pressure (IBP) transducer readings out of tolerance
IBP pressure values do not match pressure simulator input within specified tolerance range at P1 or P2 ports
Ranked causes
- 1. IBP transducer or cable faulty or sensor miscalibrated (common)
Enable P1 and P2 in SYSTEM CONFIG and PARAMETERS
- Test point
- DCU SETUPS / SERVICE / SYSTEM CONFIG and SETUPS / PARAMETERS SELECTION menus
- Expected
- P1 and P2 turned ON
4 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Neonatal NIBP cuff measurement failure patient safety
Neonatal cuff does not inflate to expected pressure, measurement incomplete, or numeric readings missing when measuring neonatal blood pressure on finger held above shoulder height
Ranked causes
- 1. Neonatal cuff disconnected, too loose, or blocked (common)
Set patient mode to NEO
- Test point
- DCU SETUPS / PATIENT MODE
- Expected
- PATIENT mode set to NEO
5 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Neonatal NIBP dead man (occlusion) cuff test failure
System does not display zero reading after neonatal cuff NIBP cycle when wrapped around fixed object without blood signal
Ranked causes
- 1. NIBP measurement algorithm does not recognize absent pulse in neonatal mode (occasional)
Set patient mode to NEO
- Test point
- DCU SETUPS / PATIENT MODE
- Expected
- PATIENT mode set to NEO
3 more checks with pass and fail actions are in ServiceForge. Connect ServiceForge to your AI
NIBP calibration accuracy error at high pressure
Pressure transducer reading not within tolerance when 250 mmHg applied to NIBP pump port
Ranked causes
- 1. Secondary or primary pressure transducer drift or failure (common)
Set patient mode and apply pressure to secondary pump port
- Test point
- NIBP Pump (right) port
- Expected
- 250 mmHg applied
2 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
NIBP calibration error when not in standby
CALIB message does not appear within timeout when NIBP START/STOP button pressed outside of standby mode
Ranked causes
- 1. System not in required standby state for safe calibration (common)
Ensure unit NOT in STANDBY mode and apply 15 mmHg pressure
- Test point
- System mode, NIBP pump input
- Expected
- Unit active, 15 mmHg applied
2 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
NIBP dead man (occlusion) cuff test failure
System does not display zero reading when NIBP cuff placed around fixed object with no blood flow
Ranked causes
- 1. NIBP algorithm or sensor cannot detect absence of blood flow signal (occasional)
Connect adult cuff around fixed 1 inch diameter object
- Test point
- NIBP cuff placement
- Expected
- Cuff tight around rigid object, no pulse signal
2 more checks with pass and fail actions are in ServiceForge. Connect ServiceForge to your AI
NIBP leak time out error
NIBP pump does not shut off within specified timeout or does not display NOT INFLATING error message when cuff disconnected
Ranked causes
- 1. NIBP pump timeout circuit or pressure sensor failure (common)
Remove all cuff connections and open NIBP ports (adult mode)
- Test point
- NIBP pump ports
- Expected
- All connections removed, ports open to atmosphere
7 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
NIBP offset reading out of tolerance
NIBP pressure offset not within specified range when no pressure applied
Ranked causes
- 1. NIBP transducer requires recalibration (common)
Apply no pressure to NIBP system
- Test point
- NIBP pump
- Expected
- No applied pressure
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
O2 sensor expiration or calibration error
O2 sensor expired or does not calibrate to correct ambient oxygen value (21%) after performing O2 initialization calibration
Ranked causes
- 1. O2 sensor cartridge expired or calibration drift (common)
Insert Artema O2 sensor into sensor port
- Test point
- O2 sensor port at back of Cart
- Expected
- O2 sensor cartridge fully inserted
3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Power supply communication not verified before patient use patient safety
Expression MRI Patient Monitoring System communication with DCU not verified prior to patient use, risking system malfunction during monitoring.
Ranked causes
- 1. Communication verification not performed (common)
Test communication between Expression system and DCU
- Test point
- Expression system wireless transceiver and DCU receiver
- Expected
- Bidirectional communication established; no errors or timeouts
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Respiration rate not displaying patient safety
DCU does not show respiration rate or rate is inconsistent with normal range
Ranked causes
- 1. Respiration sensor or bellows connection issue (unknown)
Verify respiration rate display
- Test point
- DCU respiration display
- Expected
- Rate consistent with normal respiration (10-16 BPM), 10-16 BPM
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Temperature reading not accurate patient safety
Temperature probe reading does not match ambient temperature within tolerance
Ranked causes
- 1. Temperature probe malfunction or sensor drift (unknown)
Verify temperature probe reading accuracy
- Test point
- Temperature display vs. ambient
- Expected
- Ambient temperature ±2°C, ±2°C
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Unused DC output not covered on power supply MRI environment
DC Output Connector on power supply P/N 989803168201 left uncovered when only one output is used, causing noise artifacts on MR image.
Ranked causes
- 1. Unused DC output uncovered (common)
Inspect DC output connectors on power supply
- Test point
- DC Output Connectors (2) on P/N 989803168201
- Expected
- Unused output covered with Shield Cap
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Wireless ECG or SpO2 module battery creates image artifact
9065 battery or WECG/WSpO2 module positioned in MR field of view causing image artifact
Ranked causes
- 1. Battery or module in MR field of view (occasional)
Verify WECG/WSpO2 module and 9065 battery location relative to MR field of view
- Test point
- Module and battery position
- Expected
- Located outside MR imaging field of view
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Error codes
| Code | Meaning | Trigger | Severity |
|---|---|---|---|
Communication Error | Loss or degradation of wireless communication between Expression system and DCU | Expression and DCU operating in same MR room or high-powered radio transmitter operating nearby | warning |
Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI
Community
0 fixes logged by technicians through their AI, with outcomes, for this model.
ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.