Hospira Plum A+: troubleshooting and error codes
The ServiceForge knowledge base holds 40 documented symptoms for the Hospira Plum A+, with 75 ranked causes, 66 diagnostic checks with test points and expected values, and 145 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
Occlusion not detected patient safety
Proximal or distal occlusion test fails, system does not detect tubing blockage
Ranked causes
- 1. Cassette not properly primed (common)
- 2. Defective cassette (common)
- 3. Dirty sensor pin (occasional)
- 4. Defective APP PWA (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Proximal occlusion test failure patient safety
Proximal line occlusion detection does not function
Ranked causes
- 1. Closed proximal clamp (common)
- 2. Cassette priming issue (common)
- 3. Defective cassette or sensor (occasional)
- 4. Defective APP PWA (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Air in line not detected patient safety
Proximal or distal air-in-line test fails, system does not detect air bubbles in tubing
Ranked causes
- 1. Defective special cassette (common)
- 2. Dirty sensors (common)
- 3. Defective APP PWA (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Air-in-line detection failure patient safety
Proximal or distal air detection does not function
Ranked causes
- 1. Defective special cassette (common)
- 2. Dirty sensors (common)
- 3. Defective APP PWA (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Alarm loudness test fails
Alarm does not produce expected sound level during test
Ranked causes
- 1. Defective CPU (occasional)
- 2. Defective peripheral PWA (occasional)
- 3. Defective piezo alarm assembly (common)
Run Alarm Loudness Test
- Test point
- Alarm sound output
- Expected
- Alarm produces required sound level
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Alarm loudness test failure caution
Alarm audible output does not meet specification
Ranked causes
- 1. Defective CPU (common)
- 2. Defective peripheral PWA (occasional)
- 3. Defective piezo alarm (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Alarm not sounding patient safety
Alarm loudness test fails or alarm inaudible during operation
Ranked causes
- 1. Defective CPU PWA (common)
- 2. Defective peripheral PWA (occasional)
- 3. Defective piezo alarm assembly (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Delivery accuracy error patient safety
Delivery accuracy test fails, infusion rate or volume measurement inaccurate
Ranked causes
- 1. Cassette not properly primed (common)
- 2. Damaged or faulty cassette (common)
- 3. Defective mechanism assembly (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Delivery accuracy test failure patient safety
Infusion delivery rate does not meet specification
Ranked causes
- 1. Cassette priming issue (common)
- 2. Damaged or faulty cassette (common)
- 3. Defective mechanism (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Distal occlusion test failure patient safety
Distal line occlusion detection does not function
Ranked causes
- 1. Cassette priming issue (common)
- 2. Defective cassette or sensor (occasional)
- 3. Defective APP PWA (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Air-in-line detected patient safety
Air bubbles detected in delivery cassette by proximal or distal air sensors; alarm N230-N234 generated
Ranked causes
- 1. Proximal air accumulation (> 500 µL) (common)
- 2. Distal air bolus or cumulative air (≥ 100 µL) (occasional)
Verify air volume in proximal chamber
- Test point
- Cassette proximal reservoir
- Expected
- Less than 500 µL air visible
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Nurse call function test
Verify nurse call circuit operates correctly. Set primary rate to 400 mL/hr with 1 mL dose limit, observe short circuit reading on DMM after DOSE END and KVO appear.
Ranked causes
- 1. Nurse call test procedure as part of service verification (common)
- 2. Nurse call function not used (bypass test) (occasional)
Primary rate and dose limit configuration
- Test point
- Display
- Expected
- Rate 400 mL/hr, dose limit 1 mL
3 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cassette alarm test failure caution
Cassette alarm function does not operate during test
Ranked causes
- 1. Cassette seating issue (common)
- 2. Defective cassette (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cassette test fails or CASSETTE TEST FAIL message displayed
LCD displays CASSETTE TEST FAIL flashing message and alarm sounds after inserting empty or primed cassette
Ranked causes
- 1. Empty cassette inserted for alarm test (common)
- 2. Cassette hardware or sensor malfunction (rare)
Verify infuser is powered on before cassette insertion
- Test point
- LCD display and power indicator
- Expected
- Infuser on with DELIVERY screen or CCA selection screen displayed
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Door open while pumping or cassette insertion failure patient safety
Door opened during delivery or cassette not properly inserted; alarm N250 or N251 generated
Ranked causes
- 1. Door physically open or cassette loose (common)
- 2. Cassette or valve leak test failure (occasional)
Verify door is closed
- Test point
- Door sensor/latch
- Expected
- Door fully closed and latched
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Ethernet connection not functioning
Green LED on CE module is not illuminated when Ethernet connection should be active.
Ranked causes
- 1. Ethernet cable not properly connected to RJ-45 connector (common)
- 2. Green LED on CE module not illuminated (unknown)
Verify shielded Ethernet cable is connected to RJ-45 connector
- Test point
- RJ-45 Ethernet connector on CE module
- Expected
- Shielded Ethernet cable firmly inserted
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Free flow test failure patient safety
Free flow detection does not function properly
Ranked causes
- 1. Cassette seating or defect (common)
- 2. Dirty or defective valve pins (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Minimal or no fluid flow during free flow test patient safety
Distal tubing shows no flow or excessive flow instead of minimal drops when cassette door open or closed
Ranked causes
- 1. Normal operation during free flow test (common)
- 2. Excessive free flow indicating improper cassette seating or valve malfunction (occasional)
Prepare test setup with primed cassette and collection container
- Test point
- Cassette, tubing, collection container positioning
- Expected
- Primed cassette installed, distal tubing end minimum 36 inches below cassette in collection container
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Occlusion detected during delivery or non-delivery patient safety
Proximal or distal occlusion alarm generated (N180-N191); delivery line blocked or kinked
Ranked causes
- 1. Distal occlusion (delivery line blocked) (common)
- 2. Proximal occlusion (cassette inlet blocked) (common)
Inspect distal line for occlusion
- Test point
- IV line from cassette to patient
- Expected
- Line patent; no kinks, clamps or visible blockage
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Power on failure or unexpected shutdown patient safety
Infuser does not power on or powers off unexpectedly; low battery warnings or depleted battery message displayed
Ranked causes
- 1. Battery discharged or depleted (common)
- 2. Battery charging circuit failure (occasional)
Verify battery terminal voltage
- Test point
- Battery terminals
- Expected
- Voltage greater than 5.45 V, > specified
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Self test fails patient safety
Device self test does not complete successfully
Ranked causes
- 1. Cassette not properly installed (common)
- 2. Defective CPU PWA (rare)
Verify cassette installation
- Test point
- Cassette seating
- Expected
- Cassette fully seated in device
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Self test failure
Device power-on self test fails or cannot complete
Ranked causes
- 1. Cassette not properly installed or seated (common)
- 2. Defective CPU PWA (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Unrestricted flow event patient safety
Infusion flows without control; regulator closer not properly seated or administration set clamp open
Ranked causes
- 1. Regulator closer not completely seated (common)
- 2. Administration set clamp not closed (common)
Inspect regulator closer seating
- Test point
- Regulator closer position
- Expected
- Regulator closer completely seated
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Delivery accuracy verification patient safety
Verify infusion pump delivers correct volume at programmed rate. Test dual-line system with 200 mL/hr rate and 10 mL dose on each line, confirm final delivery is 20 mL ± 1 mL total and KVO/alarm sound at completion.
Ranked causes
- 1. Calibration procedure as part of maintenance and service tests (common)
Cassette door inserted and NEW PATIENT confirmed
- Test point
- Display screen
- Expected
- NEW PATIENT? message appears, then NEW PATIENT confirmed with YES
8 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Electrical safety verification high voltage
Verify AC mains leakage current and ground resistance meet safety specifications. Test enclosure leakage (normal and open ground), earth leakage, and chassis ground resistance using a safety analyzer.
Ranked causes
- 1. Electrical safety test procedure required for service verification (common)
Power cord and analyzer connection
- Test point
- AC mains inlet and ground test point
- Expected
- Power cord connected to safety analyzer, ground lead connected to rear ground screw
6 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Display backlight or contrast not adjustable or illegible
LCD backlight does not illuminate, cannot be adjusted, or display contrast cannot be changed; screen not legible from 18 inches at eye level
Ranked causes
- 1. Backlight or display hardware malfunction (rare)
Verify LCD backlight is on and display legible
- Test point
- LCD display at eye level
- Expected
- Backlight illuminated, display clearly legible from approximately 18 inches distance
3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Display test fails
Device display does not function during test
Ranked causes
- 1. Defective display assembly (common)
Run Display Test
- Test point
- Display output
- Expected
- Display functions and shows output
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Fluid shield tab bent or damaged patient safety
Visual inspection reveals fluid shield tab is bent or damaged, which may unseat regulator closer and cause unrestricted flow
Ranked causes
- 1. Fluid shield tab bent or damaged during removal or installation (occasional)
Visually inspect fluid shield tab
- Test point
- Fluid shield tab visible from open corner of mechanism assembly
- Expected
- Tab is straight and not bent or damaged
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Gasket tape installation on mechanism chassis caution
Installation of gasket tape to cover opening on mechanism chassis to protect Switch PWA from fluid ingress
Ranked causes
- 1. Missing or inadequate gasket tape coverage on mechanism chassis opening (occasional)
Verify gasket tape presence and alignment
- Test point
- Mechanism chassis opening
- Expected
- Gasket tape installed and covering opening, secure and not protruding beyond chassis
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Keypad functional test failure caution
Keypad does not respond correctly during testing
Ranked causes
- 1. Defective keypad (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Keypad not responding
Keypad verification or functional test fails, keys not responding to input
Ranked causes
- 1. Defective keypad (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Keypad or softkey function not responding or producing incorrect results patient safety
Keypad entries not registered, softkeys not functioning, START/STOP/programmed rates not executing, LED indicators not responding, or incorrect rate/VTBI values displayed
Ranked causes
- 1. Keypad or firmware malfunction preventing input or operation (occasional)
Select line A and verify PROGRAM screen displays
- Test point
- LCD display, softkey A
- Expected
- PROGRAM screen displayed after pressing A softkey from DELIVERY screen
10 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Keypad test fails
Keypad does not respond during functional test
Ranked causes
- 1. Defective keypad (common)
Run Keypad Verification/Functional Test
- Test point
- Keypad response
- Expected
- Keypad responds to input
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Lockout switch test failure caution
Cassette lockout mechanism does not function
Ranked causes
- 1. Defective peripheral PWA (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Self test fails or alarm condition during startup patient safety
LCD does not display SELF TEST screen or alarm condition recurs when power cycled
Ranked causes
- 1. Hardware or firmware malfunction preventing self test completion (unknown)
Verify AC power connection and CHARGE indicator
- Test point
- CHARGE/LINE indicator LED
- Expected
- CHARGE illuminates and alarm tone sounds
2 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Unit does not deliver fluid or displays error during priming patient safety
Pump fails to deliver fluid or shows malfunction when executing the delivery accuracy test sequence, including cassette insertion and programming.
Ranked causes
- 1. Pump mechanism malfunction or cassette issue (unknown)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Unrestricted flow (regulator closer disengaged) patient safety
No alarm generated; door opening with disengaged regulator closer may cause uncontrolled fluid delivery
Ranked causes
- 1. Regulator closer mechanism disengaged or not fully engaged (rare)
Remove mechanism and inspect regulator closer
- Test point
- Regulator closer assembly
- Expected
- Regulator closer fully engaged and moving freely
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Unrestricted flow risk patient safety
Regulator closer not properly seated, creates risk of uncontrolled fluid flow
Ranked causes
- 1. Regulator closer not properly seated (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
VTBI complete (programmed volume infused) patient safety
Alarm N160 or N161 generated; infusion of programmed volume complete on line A or B
Ranked causes
- 1. VTBI (volume to be infused) reached (common)
Verify programmed volume delivered
- Test point
- Volume counter on display
- Expected
- Volume infused equals VTBI setting
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Wireless connection not available
Wireless Connection Available icon does not appear on the main delivery screen when device should be receiving a wireless signal.
Ranked causes
- 1. Wireless network access point not recognized or signal not being received (unknown)
Verify Wireless Connection Available icon appears on main delivery screen
- Test point
- Main delivery screen
- Expected
- Wireless Connection Available icon is displayed
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Error codes
| Code | Meaning | Trigger | Severity |
|---|---|---|---|
DEPLETED BATTERY (Info) | Battery completely discharged | Device turned on without being plugged in while battery is depleted | info |
E300 | ADC failure - analog to digital converter malfunction | ADC converter failure detected | critical |
E300 | ADC failure | Analog to digital converter failure | error |
E301 | Audio alarm failure | Piezo is off but sensed on or piezo is on but sensed off | error |
E302 | Backlight failure | Backlight CCFT tube not at expected range | error |
E320 | Battery charge/discharge current out of range | Current limiting circuitry malfunction or excessive current draw | error |
E321 | Charging current failure to drop within threshold | Charging current does not drop below end-of-charge threshold within 8 hours or below 1A within 6 hours | warning |
E321 | Battery not charging | Battery charging timed out or complete battery discharge has occurred | critical |
E322 | Battery current calibration value out of range | Charge current measurement circuitry failure | error |
E323 | Battery trickle charge current out of range | Trickle charge current outside specification | error |
E324 | Supply overvoltage - charging circuit fault | Charging circuit produces excessive voltage | critical |
E325 | Battery overvoltage | Battery voltage exceeds specification | error |
E326 | Battery disconnected while infuser on or voltage too low | Battery connection loss detected during operation or voltage below minimum | critical |
E327 | Brownout condition | Brownout condition detected | error |
E340 | Critical instruction failure - CPU register test failed | Power-up CPU register test failure | critical |
E341 | Critical data memory failure | Critical data memory checksum or access failure | critical |
E342 | Display failure - defective display | Display malfunction detected | error |
E343 | Distal air sensor failure 1 - detects liquid with cassette removed | Self-test detects liquid with cassette out | error |
E344 | Distal air sensor failure 2 - sensor out of range | Self-test with cassette inserted detects out-of-range | error |
E345 | Distal pressure sensor failure 1 - failed while off | Sensor failure detected during standby | error |
E346 | Distal pressure sensor failure 2 - failed while on | Sensor failure detected during operation | error |
E347 | Hardware watchdog failure | Hardware watchdog timer malfunction | critical |
E378 | I/O valve phase loss | I/O valve motor phase detection failure | error |
E379 | L/S valve phase loss | L/S valve motor phase detection failure | error |
E380 | Plunger motor phase loss - generic motor failure | Motor output loss detected | error |
E430 | Proximal air sensor failure 1 - detects liquid cassette removed | Ongoing test detects liquid with cassette out | error |
E431 | Proximal air sensor failure 2 - self test detects liquid | Self-test detects liquid with cassette removed | error |
E432 | Proximal pressure sensor failure 1 - failed while off | Sensor failure detected during standby | error |
E433 | Proximal pressure sensor failure 2 - failed while on | Sensor failure detected during operation | error |
E434 | RAM failure | RAM memory test failure | error |
E435 | RTC failure | Real-time clock malfunction | error |
E435 | RTC failure - real-time clock malfunction | Real-time clock circuit failure | error |
E436 | ROM failure | ROM checksum verification failure | error |
E437 | Software failure - generic software malfunction | Generic software fault detected | error |
E438 | Stack out-of-range failure | Software stack pointer overflow/underflow | critical |
E439 | Stuck key - key pressed for >2 minutes | Keypad stuck in pressed state for over 2 minutes | error |
E439 | Stuck key | Key sensed as pressed for over two minutes | warning |
E440 | Power hold stuck | Power hold signal remains asserted | critical |
E443 | LCD failure - LCD bias out of range | Display bias voltage out of specification | error |
E444 | CPU timebase inaccurate | CPU timer 2 and RTC measured times disagree | warning |
E445 | RTC memory failure | Real-time clock memory corruption detected | warning |
E446 | CPU timer failure | CPU timer 1 and timer 2 measured times disagree | error |
E447 | Battery ADC reading failure - consecutive zero/max readings | 16 consecutive ADC readings all zero or maximum | error |
E448 | SEEP write failure | SEEP data write operation failed | error |
E449 | SEEP calibration data corrupted | Calibration data block checksum failure | error |
E450 | MMIO port read/write failure | Memory-mapped I/O port read/write error | error |
E451 | Inaccurate delivery | Over/under delivery detected during operation | error |
E452 | Software failure - miscellaneous software failures | Various software fault conditions | error |
E453 | Two SEEP CRC errors - NVRAM data corrupted | Multiple non-volatile RAM checksum failures | critical |
E454 | NVRAM over capacity - write to non-existent space | Software attempts to write beyond NVRAM limits | error |
E455 | Invalid device configuration | Incorrect flash memory on peripheral PWA | error |
E456 | Invalid drug library | Drug library install was started but not completed successfully | warning |
E457 | Drug library corrupted | CRC failure on drug library | error |
LOW BATTERY (Warning) | Battery has reduced capacity | Reduced battery capacity detected; first or second occurrence | warning |
N100 | Unrecognizable cassette | Incorrect cassette type inserted | warning |
N100 (URC) | Unrecognizable cassette | Incorrect cassette type inserted | error |
N101 | No Action Alarm | No operator action and no delivery for 2 minutes during parameter entry | warning |
N101 (NAA) | No action - infuser idle | No operator action and no delivery for two minutes during parameter entry | warning |
N102 | Infuser Idle 2 Minutes | Infuser in reset or idle for over 2 minutes without start command | warning |
N102 (RL) | Infuser idle over 2 minutes | Infuser in reset or idle state for over 2 minutes | warning |
N103 | NV RAM lost therapy data | Therapy data is lost | error |
N103 (SEEP CRC) | NV RAM lost therapy data | Therapy data lost due to incomplete NVRAM write | error |
N104 | Nurse callback B | Delivery line B has changed (if alarm enabled) | warning |
N104 (NC2) | Nurse callback B | Delivery line B changed while callback enabled | warning |
N105 | Nurse callback A | Delivery line A has changed (if alarm enabled) | warning |
N105 (NC1) | Nurse callback A | Delivery line A changed while callback enabled | warning |
N160 | Line B VTBI complete | Programmed volume to be infused completed on line B | info |
N160/E160 | Line B VTBI complete | Programmed VTBI completed on line B | info |
N160/E160 (VTB2) | Line B VTBI complete | Programmed VTBI completed on line B | info |
N161 | Line A VTBI complete | Programmed volume to be infused completed on line A | info |
N161/E161 | Line A VTBI complete | Programmed VTBI completed on line A | info |
N161/E161 (VTB1) | Line A VTBI complete | Programmed VTBI completed on line A | info |
N180 | Distal Occlusion | Peak distal occlusion detected during non-delivery phase | warning |
N180/E180 | Distal occlusion, peak | Distal occlusion detected during non-delivery | error |
N180/E180 (OD1) | Distal occlusion - peak, non-delivery | Peak distal occlusion detected during non-delivery | error |
N181/E181 | Distal occlusion, negative | Distal occlusion detected during non-delivery | error |
N181/E181 (OD1) | Distal occlusion - negative, non-delivery | Negative distal occlusion detected during non-delivery | error |
N182/E182 | Proximal occlusion B, negative | Proximal occlusion detected on line B during non-delivery | error |
N182/E182 (OP2) | Proximal occlusion B, air - negative, non-delivery | Negative proximal occlusion B detected during non-delivery | error |
N183 | Prox Occl B At Startup | Peak proximal occlusion B detected during non-delivery startup | warning |
N183/E183 | Proximal occlusion B, peak | Proximal occlusion detected on line B during non-delivery | error |
N183/E183 (OP2) | Proximal occlusion B, air - peak, non-delivery | Peak proximal occlusion B detected during non-delivery | error |
N184 | Prox Occl A / Air | Negative proximal occlusion A detected during non-delivery | warning |
N184/E184 | Proximal occlusion A, negative | Proximal occlusion detected on line A during non-delivery | error |
N184/E184 (OP1) | Proximal occlusion A, air - negative, non-delivery | Negative proximal occlusion A detected during non-delivery | error |
N185 | Prox Occl A At Startup | Peak proximal occlusion A detected at startup non-delivery | warning |
N185/E185 | Proximal occlusion A, peak | Proximal occlusion detected on line A during non-delivery | error |
N185/E185 (OP1) | Proximal occlusion A, air - peak, non-delivery | Peak proximal occlusion A detected during non-delivery | error |
N186 | Distal Occlusion | Peak distal occlusion detected during delivery | error |
N186/E186 | Distal occlusion during delivery, peak | Distal occlusion detected during delivery | error |
N186/E186 (OD1) | Distal occlusion - peak, delivery | Peak distal occlusion detected during delivery | error |
N187 | Neg Distal Occlusion | Negative distal occlusion during delivery | error |
N187/E187 | Distal occlusion during delivery, negative | Distal occlusion detected during delivery | error |
N187/E187 (OD1) | Distal occlusion - negative, delivery | Negative distal occlusion detected during delivery | error |
N188 | Prox Occl B / Air | Negative proximal occlusion B during delivery | error |
N188/E188 | Proximal occlusion B during delivery, negative | Proximal occlusion detected during delivery on line B | error |
N188/E188 (OP2) | Proximal occlusion B - negative, delivery | Negative proximal occlusion B detected during delivery | error |
N189 | Prox Occl B / Air | Peak proximal occlusion B during delivery | error |
N189/E189 | Proximal occlusion B during delivery, peak | Proximal occlusion detected during delivery on line B | error |
N189/E189 (OP2) | Proximal occlusion B - peak, delivery | Peak proximal occlusion B detected during delivery | error |
N190 | Prox Occl A / Air | Negative proximal occlusion A during delivery | error |
N190/E190 | Proximal occlusion A during delivery, negative | Proximal occlusion detected during delivery on line A | error |
N190/E190 (OP1) | Proximal occlusion A - negative, delivery | Negative proximal occlusion A detected during delivery | error |
N191 | Prox Occl A / Air | Peak proximal occlusion A during delivery | error |
N191/E191 | Proximal occlusion A during delivery, peak | Proximal occlusion detected during delivery on line A | error |
N191/E191 (OP1) | Proximal occlusion A - peak, delivery | Peak proximal occlusion A detected during delivery | error |
N230 | Prox Air, Backprime | 500 µL air accumulated in proximal line (combined both lines) | warning |
N230/E230 | Proximal air total | 500 µL of air has entered the cassette | error |
N230/E230 (APT) | Proximal air-in-line total | 500 microliter of air entered cassette | error |
N231 | Prox Air B, Backprime | 500 µL air accumulated in proximal line B | warning |
N231/E231 | Proximal air on line B | 500 µL of air has entered the cassette on line B | error |
N231/E231 (APB) | Proximal air on B, backprime | 500 microliter of air entered cassette on line B | error |
N232 | Prox Air A, Backprime | 500 µL air accumulated in proximal line A | warning |
N232/E232 | Proximal air on line A | 500 µL of air has entered the cassette on line A | error |
N232/E232 (APA) | Proximal air on A, backprime | 500 microliter of air entered cassette on line A | error |
N233 | Distal Air | 500 µL cumulative air detected in last 5.3 mL fluid delivered | warning |
N233/E233 | Distal air cumulative | 500 µL of air detected in the last 5.3 mL of fluid delivered | error |
N233/E233 (ADC) | Distal air cumulative | 500 microliter air detected in last 5.3 mL delivered | error |
N234 | Distal Air | 100 µL air bolus detected at distal sensor | warning |
N234/E234 | Distal air bolus | 100 µL bolus of air detected at distal sensor | error |
N234/E234 (ADB) | Distal air bolus | 100 microliter bolus of air detected at distal sensor | error |
N250 | Door open while pumping | Door opened during active delivery | error |
N250/E250 | Door opened while pumping | Door opened while pumping | critical |
N250/E250 (DCO1) | Door opened while pumping | Infuser door opened during active pumping | error |
N251 | Cassette Test Failure | Valve/cassette fails leak test | error |
N251/E251 | Valve/cassette test failure | Valve/cassette fails the leak test | error |
N251/E251 (CS1) | Valve/cassette test failure | Valve/cassette fails leak test | error |
N252 | Depleted Battery | Low battery terminal voltage during operation | critical |
N252/E252 | Depleted battery | Battery terminal voltage is less than 5.45 V | error |
N252/E252 (BDP) | Depleted battery | Battery terminal voltage less than 5.45 V | error |
N253 | Hard lockout Violation | Attempt to use [STOP] key or open door while hard lockout engaged | warning |
N253/E253 | Lockout violation, hard | Use of [STOP] key or attempt to open door while lockout switch is locked | warning |
N253/E253 (LOV) | Lockout violation - hard | STOP key pressed or door open attempt while lockout active | unknown |
N254 | Hard Lockout Enabled | Keypad action taken while hard lockout switch locked | warning |
N254/E254 | Lockout enabled, keypad locked | Any action not resulting in stopping of delivery while lockout switch is locked | warning |
N254/E254 (FPL) | Lockout enabled - keypad locked | Action not stopping delivery while lockout enabled | unknown |
N255 | Soft lockout Violation | Attempt to use [STOP] key or open door while soft lockout enabled | warning |
N255 (SLV) | Soft lockout violation | STOP key pressed or door open attempt while soft lockout active | warning |
N256 | Soft lockout Enabled | Keypad action taken while soft lockout switch locked | warning |
N256 (SLE) | Soft lockout enabled | Action not stopping delivery while soft lockout enabled | warning |
No Alarm | Unrestricted flow | Regulator closer disengaged and door opens | unknown |
REPLACE BATTERY (Warning) | Battery must be replaced immediately | Third and subsequent occurrences of reduced battery capacity | warning |
Warning: Charger Service | Charger hardware problem | Battery charging circuit malfunction detected | unknown |
Warning: Low Battery | Low battery warning | Battery discharged to approximately 30 minutes of operation remaining | warning |
Warning: Replace Battery | Battery service needed | Battery voltage less than depleted threshold and charge above low threshold | warning |
Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI
Community
0 fixes logged by technicians through their AI, with outcomes, for this model.
ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.