FR FieldReady Academy
Test equipment workstations

Hewlett-Packard xw6400 Workstation: troubleshooting and error codes

The ServiceForge knowledge base holds 158 documented symptoms for the Hewlett-Packard xw6400 Workstation, with 272 ranked causes, 157 diagnostic checks with test points and expected values, and 79 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI

Symptoms

Sound does not come out of speaker or headphones

No audio output from speaker or headphones despite audio playback expected

Ranked causes

  1. 1. Software volume control turned down (common)
  2. 2. External speakers not turned on (common)
  3. 3. External speakers plugged into wrong audio jack (occasional)
  4. 4. Audio cable not connected (common)
  5. 5. Digital CD audio is not enabled (occasional)
  6. 6. Headphones or devices connected to line-out connector mute internal speaker (occasional)
  7. 7. Volume is muted (common)
  8. 8. Computer is in Standby mode (common)

8 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Unable to connect to the Internet

System cannot establish connection to Internet service

Ranked causes

  1. 1. Internet Service Provider account not set up properly (occasional)
  2. 2. Modem not set up properly (common)
  3. 3. Web browser not set up properly (occasional)
  4. 4. Cable/DSL modem not plugged in (common)
  5. 5. Cable/DSL service not available or interrupted by weather (occasional)
  6. 6. CAT5 10/100/1000 cable disconnected (common)
  7. 7. IP address not configured properly (occasional)
  8. 8. Cookies corrupted (rare)

8 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Blank screen (no video)

Monitor displays nothing, workstation powered on

Ranked causes

  1. 1. Cable connections not correct (common)
  2. 2. Monitor is off (common)
  3. 3. Screen blanking utility or energy saver enabled (occasional)
  4. 4. System ROM is bad; FailSafe Boot Block mode active (rare)
  5. 5. Fixed-sync monitor incompatible with resolution (occasional)
  6. 6. Computer in Sleep/Standby mode (common)
  7. 7. Monitor settings incompatible with graphics card (occasional)

7 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Diskette drive cannot write to diskette

System cannot write data to a diskette; write operations fail

Ranked causes

  1. 1. Diskette is not formatted (common)
  2. 2. Diskette is write-protected (common)
  3. 3. Writing to the wrong drive (occasional)
  4. 4. Not enough space is left on the diskette (common)
  5. 5. Diskette write control is enabled (occasional)
  6. 6. Diskette is damaged (occasional)

6 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

New device not recognized as part of system

Newly installed hardware is not detected or recognized by workstation

Ranked causes

  1. 1. Device not seated or connected properly (common)
  2. 2. Cables of new external device loose or power cables unplugged (common)
  3. 3. Power switch of new external device not turned on (occasional)
  4. 4. Configuration changes not accepted when prompted (occasional)
  5. 5. PnP board conflict with existing devices (occasional)
  6. 6. Device hardware not properly jumpered or otherwise configured (occasional)

6 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

System does not power on

No Power LED indication; system fails to start

Ranked causes

  1. 1. AC power not available (common)
  2. 2. Power button harness disconnected (occasional)
  3. 3. Power supply cables disconnected (occasional)
  4. 4. Power supply failure (occasional)
  5. 5. Expansion card failure (rare)
  6. 6. System board failure (rare)
First check

Verify AC outlet power

Test point
AC outlet
Expected
Working AC power present
Tools
Power meter

3 more checks with pass and fail actions, 6 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Diagnostics reports network failure

Network diagnostics test fails with error condition

Ranked causes

  1. 1. Cable not securely connected (common)
  2. 2. Cable attached to incorrect connector (occasional)
  3. 3. Problem with cable or remote device (occasional)
  4. 4. Network controller interrupt shared with expansion board (occasional)
  5. 5. Network controller is defective (rare)

5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Keyboard commands and typing not recognized

Keyboard input is not responded to by workstation or active application

Ranked causes

  1. 1. Keyboard connector not properly connected (common)
  2. 2. Program in use has stopped responding to commands (common)
  3. 3. Keyboard needs repairs (rare)
  4. 4. Keyboard key is stuck down (occasional)
  5. 5. Workstation is in Sleep/Standby mode (occasional)

5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Thermal shutdown occurred caution

Power LED blinks red 2 times, 2 beeps; thermal protection activated

Ranked causes

  1. 1. Blocked air vents (common)
  2. 2. Cooling fan not running (common)
  3. 3. Processor fan not running (common)
  4. 4. Processor fan failure (occasional)
  5. 5. CPU heatsink improperly attached (occasional)
First check

Inspect air vents

Expected
Air vents clear and unobstructed
Tools
Visual inspection

3 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

USB device, headphone, or microphone not recognized

USB peripheral or audio device is not detected or recognized by workstation

Ranked causes

  1. 1. Device not properly connected (common)
  2. 2. Device does not have power (occasional)
  3. 3. Correct device driver not installed (common)
  4. 4. Cable from device to computer does not work (occasional)
  5. 5. Device is not working (rare)

5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Cannot boot to diskette

System will not boot from diskette drive

Ranked causes

  1. 1. Diskette is not bootable (common)
  2. 2. Diskette boot has been disabled in Computer Setup (common)
  3. 3. Removable media boot has been disabled in Computer Setup (occasional)
  4. 4. Diskette MBR validation is enabled (occasional)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Diskette drive cannot read diskette

Diskette drive cannot read data from a diskette; read operations fail

Ranked causes

  1. 1. Diskette is not formatted (common)
  2. 2. You are using the wrong diskette type for the drive type (occasional)
  3. 3. You are reading the wrong drive (occasional)
  4. 4. Diskette is damaged (occasional)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Diskette drive light stays on

Diskette drive activity LED remains illuminated continuously or abnormally

Ranked causes

  1. 1. Diskette is damaged (common)
  2. 2. Diskette is incorrectly inserted (common)
  3. 3. Files on diskette are damaged (occasional)
  4. 4. Drive cable is not properly connected (occasional)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Mouse does not respond to movement or is too slow

Mouse cursor does not move on screen or responds very slowly to mouse movements

Ranked causes

  1. 1. Mouse connector not properly plugged into back of workstation (common)
  2. 2. Program in use has stopped responding to commands (common)
  3. 3. Mouse needs repairs (rare)
  4. 4. Workstation is in Standby mode (occasional)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Network status link light does not illuminate or never flashes

No network activity indicator on the network adapter

Ranked causes

  1. 1. No active network detected (common)
  2. 2. Network controller not set up properly (occasional)
  3. 3. Network driver not properly loaded (occasional)
  4. 4. System cannot auto-sense the network (occasional)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Nonsystem disk/NTLDR missing message

System displays 'Nonsystem disk/NTLDR missing' error message; cannot boot

Ranked causes

  1. 1. System is trying to start from a non-bootable diskette (common)
  2. 2. System is trying to start from a damaged hard drive (common)
  3. 3. System files missing or not properly installed (occasional)
  4. 4. Hard drive boot disabled in Computer Setup (occasional)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Pre-video graphic card error

Power LED blinks red 6 times, 6 beeps

Ranked causes

  1. 1. Integrated graphics system failure (occasional)
  2. 2. Graphic card not seated (common)
  3. 3. Graphic card failure (occasional)
  4. 4. System board defect (rare)
First check

Reseat graphic card

Expected
Graphic card fully seated in slot
Tools
Visual inspection

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Pre-video memory error

Power LED blinks red 5 times, 5 beeps

Ranked causes

  1. 1. Memory not properly seated (common)
  2. 2. Faulty memory module (occasional)
  3. 3. Third-party memory incompatible (occasional)
  4. 4. System board defect (rare)
First check

Reseat memory modules

Expected
Memory modules fully seated and locked
Tools
Visual inspection

1 more check with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Printer does not print

Printer does not produce any output despite print command sent

Ranked causes

  1. 1. Printer not turned on and online (common)
  2. 2. Correct printer driver for application not installed (common)
  3. 3. No connection made to network printer (occasional)
  4. 4. Printer might have failed (rare)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

CD-ROM, CD-RW, DVD-ROM, or DVD-R/RW drive cannot read disc or takes too long

Optical drive fails to read media or shows excessive access time

Ranked causes

  1. 1. CD inserted upside down (common)
  2. 2. DVD-ROM requires time to determine media type (occasional)
  3. 3. CD or DVD disc is dirty (occasional)

3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Hard drive not found (identified)

Hard drive is not recognized or detected by the system

Ranked causes

  1. 1. Loose cable (common)
  2. 2. The system might not have automatically recognized a newly installed device (common)
  3. 3. Drive jumper settings might be incorrect (occasional)

3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

IEEE-1394 device not responsive

Firewire/IEEE-1394 external device does not respond to commands

Ranked causes

  1. 1. Cables of new external device loose or power cables unplugged (common)
  2. 2. Power switch on device not turned on (common)
  3. 3. IEEE-1394 port is not active; port not purchased with system (rare)

3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Network controller stopped working after expansion board added

Network connectivity lost immediately after installing an expansion card

Ranked causes

  1. 1. Network controller interrupt shared with expansion board (common)
  2. 2. Expansion board is a network card conflicting with embedded card (occasional)
  3. 3. Network controller requires drivers (occasional)

3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Network controller stops working without apparent cause

Network connection suddenly ceases functioning with no warning or error

Ranked causes

  1. 1. Files containing network drivers are corrupted (occasional)
  2. 2. Cable not securely connected (common)
  3. 3. Network controller is defective (rare)

3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Power supply failure high voltage

Power LED blinks red 4 times, 4 beeps

Ranked causes

  1. 1. Power supply cable disconnected (common)
  2. 2. Faulty internal device (occasional)
  3. 3. Power supply defect (occasional)
First check

Verify four-wire power cable

Test point
Power supply cable to system board
Expected
Cable firmly connected

1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Printer prints garbled information

Printed output is corrupted, illegible, or contains wrong characters

Ranked causes

  1. 1. Correct printer driver not installed (common)
  2. 2. Cables not connected properly (common)
  3. 3. Printer memory overloaded (occasional)

3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Workstation will not start

Workstation fails to boot or power up after new hardware installation

Ranked causes

  1. 1. Wrong memory modules used or installed in wrong location (common)
  2. 2. PCI Express power cable plugged into wrong connector (occasional)
  3. 3. Memory installed incorrectly or is bad (common)

3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Blurry video or requested resolution cannot be set

Video image appears blurry or system cannot set desired resolution

Ranked causes

  1. 1. Correct video drivers not loaded after graphics controller upgrade (occasional)
  2. 2. Monitor not capable of displaying requested resolution (occasional)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

CPU not installed

Power LED blinks red 3 times, 3 beeps

Ranked causes

  1. 1. CPU not installed in socket (common)
  2. 2. CPU not properly seated (common)
First check

Verify CPU installed

Expected
CPU present in processor socket
Tools
Visual inspection

1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Diagnostics passes but workstation does not communicate with network

Network tests succeed but no actual data transmission occurs

Ranked causes

  1. 1. Network drivers not loaded or parameters do not match configuration (common)
  2. 2. Network controller not configured for this workstation (occasional)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Dim characters displayed

Text on monitor appears dim or low brightness

Ranked causes

  1. 1. Brightness and contrast controls not set properly (common)
  2. 2. Cables not properly connected (common)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Diskette drive not found

Diskette drive is not recognized by the system

Ranked causes

  1. 1. Cable is loose (common)
  2. 2. Removable drive is not seated properly (common)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Insufficient memory error during operation

Application or system reports lack of available memory while running

Ranked causes

  1. 1. Too many TSR programs installed (occasional)
  2. 2. Insufficient memory for application (common)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Invalid ROM checksum

Power LED blinks red 8 times, 8 beeps

Ranked causes

  1. 1. ROM firmware corruption (occasional)
  2. 2. System board defect (occasional)
First check

Reflash ROM firmware

Expected
ROM firmware successfully rewritten and verified
Tools
ROM reflash utility

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Invalid system disk message is displayed

System displays 'Invalid system disk' error message

Ranked causes

  1. 1. A diskette that does not contain the system files needed to start the workstation has been inserted in the drive (common)
  2. 2. Diskette error has occurred (occasional)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Movie will not play in DVD drive

DVD movie fails to start or play on DVD drive

Ranked causes

  1. 1. Movie regionalized for different country (occasional)
  2. 2. Decoder software not installed (common)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Network driver does not detect network controller

Network interface card is not recognized by the operating system

Ranked causes

  1. 1. Network controller is disabled (common)
  2. 2. Incorrect network driver (common)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Option ROM Error

System ROM checksum fails or Option ROM for expansion device cannot execute due to memory or corruption

Ranked causes

  1. 1. System ROM checksum failure or corrupted ROM (occasional)
  2. 2. Expansion card ROM incompatible or faulty (occasional)
First check

Flash ROM if needed

Test point
System ROM
Expected
ROM flash completes successfully

1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Out of memory error

Operating system or application reports insufficient memory available

Ranked causes

  1. 1. Memory configuration not set up correctly (occasional)
  2. 2. Insufficient memory for application (common)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Picture breaks up, rolls, jitters, or flashes

Video display exhibits horizontal or vertical instability, flickering, or distortion

Ranked causes

  1. 1. Monitor connections incomplete or monitor incorrectly adjusted (common)
  2. 2. Monitor must be degaussed (occasional)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Poor performance is experienced

System runs slowly or sluggishly

Ranked causes

  1. 1. Processor is hot (common)
  2. 2. Hard drive is full (common)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Second Ultra ATA hard drive does not perform optimally

Secondary Ultra ATA hard drive shows degraded performance or slow access

Ranked causes

  1. 1. Using the wrong cable for the drive type (common)
  2. 2. Both slow and fast UATA devices are on the same data cable (common)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

System unable to boot

Power LED blinks red 9 times, 9 beeps

Ranked causes

  1. 1. System board defect (occasional)
  2. 2. Processor defect (occasional)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

System will not boot from CD-ROM or DVD drive

Computer fails to start from bootable optical media

Ranked causes

  1. 1. CD-ROM or DVD boot not enabled in Computer Setup (common)
  2. 2. Non-bootable CD in drive (occasional)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

System will not boot or does not function after installing memory

Boot failure or system malfunction following memory module installation

Ranked causes

  1. 1. Memory module incorrect type, speed, or not seated properly (common)
  2. 2. ECC and non-ECC memory mixed (occasional)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Time and Date Not Set

Invalid or missing time/date in CMOS; RTC battery may be dead or CMOS jumper improperly installed

Ranked causes

  1. 1. RTC battery depleted (common)
  2. 2. CMOS jumper not properly installed (occasional)
First check

Set date and time in Computer Setup

Test point
F10 Setup or Control Panel
Expected
Valid date and time entered and saved

1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Workstation powered off automatically with red LED flashing 2 times caution

Unit shuts down unexpectedly; power LED flashes red 2 times once per second with 2-second pauses and two simultaneous beeps heard

Ranked causes

  1. 1. A fan might be blocked or not turning (common)
  2. 2. The CPU heatsink is not properly attached to the processor (common)

4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

A problem has occurred with a disk transaction

Disk read/write transaction has failed or encountered an error

Ranked causes

  1. 1. The directory structure is bad, or there is a problem with a file (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Audio Interrupt Conflict

Audio device IRQ address conflicts with another device

Ranked causes

  1. 1. Audio device IRQ shared with another device (occasional)
First check

Access Computer Setup IRQ assignments

Test point
F10 Setup
Expected
Audio device IRQ displayed

1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI

BIOS Update Needed for Processor

BIOS revision does not support installed processor; BIOS update required

Ranked causes

  1. 1. BIOS too old for processor (common)
First check

Verify current BIOS version

Test point
BIOS identification
Expected
BIOS version that supports processor

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Cannot automatically launch Internet programs

Internet applications fail to start automatically

Ranked causes

  1. 1. Must log on to ISP before some programs start (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Cannot connect to network server during remote system installation

System cannot reach network installation server during boot

Ranked causes

  1. 1. Network controller not configured properly (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Cannot eject CD from tray-load unit caution

CD-ROM tray will not open or cannot be manually ejected

Ranked causes

  1. 1. Disc not properly seated in drive (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Cannot format diskette

Diskette formatting operation fails or reports invalid media

Ranked causes

  1. 1. Invalid media reported (occasional)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

CD-ROM or DVD devices not detected or driver not loaded

Optical drive is not recognized by operating system or no driver available

Ranked causes

  1. 1. Drive not connected properly or not properly configured (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Chassis fan not detected caution

Chassis or case fan not properly connected, has malfunctioned, or is loose

Ranked causes

  1. 1. Chassis fan cable disconnected, loose, or fan malfunction (common)
First check

Inspect chassis fan cable connections

Test point
Fan power connectors on system board
Expected
All fan cables firmly seated

1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Clicking noise from CRT monitor caution

Audible clicking or clacking sound from inside powered CRT monitor

Ranked causes

  1. 1. Electronic relays activated inside monitor (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Computer Cover Has Been Removed Since Last System Start Up

Chassis intrusion detection switch triggered; cover was opened since last boot

Ranked causes

  1. 1. Chassis cover removed and intrusion detection triggered (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

CPU Fan not detected caution

CPU fan not properly connected, has malfunctioned, or connection is loose

Ranked causes

  1. 1. CPU fan cable disconnected or fan malfunction (common)
First check

Inspect CPU fan cable connection

Test point
CPU fan power connector on system board
Expected
Cable firmly seated or no cable visible

1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

CPU or Chassis Fan not detected caution

Either CPU or chassis fan not responding; fan cable disconnected, loose, or fan has failed

Ranked causes

  1. 1. CPU or chassis fan cable disconnected or fan malfunction (common)
First check

Reseat both CPU and chassis fan cables

Test point
Fan power connectors
Expected
All fan cables firmly seated

1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

More symptoms

  • CPU Overtemp occurred
  • Cursor will not move using arrow keys on keypad
  • DIMM Configuration Warning
  • Disk 0 Error
  • Disk 0 Failure
  • Disk 1 Error
  • Disk 1 Failure
  • Disk Controller Failure
  • Disk transaction problem
  • Diskette Controller Error
  • Diskette Drive Type Error
  • Display Adapter Failure
  • Display works during POST but goes blank on OS startup
  • Drive responds slowly immediately after power-up
  • ECC Corrected Single Bit Errors in Memory
  • ECC Memory Module Detected
  • ECC Multiple Bit Error in Memory
  • Extended ROM signature not found
  • External Storage Device Failure
  • Failed Processor
  • Fan Command 2 Pin Connector Not Connected
  • Flat-panel monitor display quality issues
  • Front Audio Not Connected
  • Front USB Not Connected
  • Game Port Address Conflict
  • Hard drive error occurs
  • High pitched noise from flat-panel monitor
  • Hood Lock Coil is not Connected
  • Inaccessible devices on primary IDE
  • Incompatible memory Module in memory Socket
  • Internet takes too long to download websites
  • Invalid Electronic Serial Number
  • Invalid Processor Jumper Setting
  • Keyboard Controller Error
  • Keyboard Error
  • Keyboard or System Unit Error
  • Master Boot Record changed
  • Master Boot Record lost
  • Memory count during POST is wrong
  • Memory Error
  • Memory Mismatch Warning
  • Memory Size Error
  • Memory Size Exceeds Maximum Supported
  • Memory Type Mismatch
  • Microcode Patch Error
  • MIDI Port Address Conflict Detected
  • Monitor does not function properly with energy saver features
  • Mouse moves only vertically or horizontally, or movement is jerky
  • Multibay incorrectly installed
  • MultiBay Riser Not Connected
  • Network Interface Card Interrupt Conflict
  • New network card will not boot
  • Noise or no sound from speakers or headphones
  • Out of Memory for Option ROMs
  • Parallel Port 2 Address Assignment Conflict
  • Parallel Port 3 Address Assignment Conflict
  • Parallel Port Address Assignment Conflict
  • Parallel Port Address Conflict Detected
  • Parity Check 2
  • Power Button Not Connected
  • Power LED flashes red 5 times and workstation beeps 5 times
  • Power LED flashes red 5 times; 5 beeps; memory or configuration issue
  • Power LED flashes red 6 times; 6 beeps; video card or system board issue
  • Power LED flashes red 6 times; 6 beeps; workstation beeps
  • Power LED is red and stays on
  • Power supply shuts down intermittently
  • Primary Diskette Port Address Assignment Conflict
  • Printer does not turn on
  • Printer is offline
  • Processor Not Supported
  • Recording audio CDs is difficult or impossible
  • SafePost Active - Expansion card not responding
  • Secondary Controller or Disk Failure
  • Secondary Disk Controller Failure
  • Serial Port 1 Address Conflict Detected
  • Serial Port 2 Address Conflict Detected
  • Serial Port Address Conflict Detected
  • SMART hard drive imminent failure
  • Sound occurs intermittently
  • Splash Screen image corrupted
  • System Audio Address Conflict Detected
  • System Board Failure
  • System does not power on and LEDs not flashing
  • System error indicated
  • System Options Not Set
  • System setup utility reports unprogrammed EEPROM
  • Temperature Alert
  • Typed symbols do not appear correctly
  • USB, audio, or IEEE-1394 device not working
  • Vibrating or rattling noise from CRT monitor
  • Wake-on-LAN feature not functioning
  • Windows does not detect CD-ROM or DVD-ROM drive
  • Workstation appears locked up and will not shut down
  • Workstation appears locked up while recording audio
  • Workstation appears to pause periodically
  • Workstation date and time display is incorrect
  • Workstation powered off with red LED flashing once every 2 seconds
  • Workstation seems to be locked up

98 more symptoms with ranked causes and checks are in ServiceForge. Connect ServiceForge to your AI

Error codes

CodeMeaningTriggerSeverity
101Option ROM ErrorSystem ROM checksum failure or Option ROM corruption during POSTerror
102System Board FailureDMA, timer, or other system board circuit test failure during POSTcritical
103System Board FailureDMA, timer, or other system board circuit failurecritical
110Out of Memory for Option ROMsOption ROM memory allocation failure during POSTerror
1151Serial Port 1 Address Conflict DetectedInternal and external serial ports assigned to COM1error
1152Serial Port 2 Address Conflict DetectedInternal and external serial ports assigned to COM2error
1155Serial Port Address Conflict DetectedInternal and external serial ports assigned to same IRQerror
1201System Audio Address Conflict DetectedAudio device IRQ conflicts with another devicewarning
1202MIDI Port Address Conflict DetectedMIDI device IRQ conflicts with another devicewarning
1203Game Port Address Conflict DetectedDevice IRQ address conflicts with another device during POSTwarning
150SafePost ActivePCI expansion card fails to respond during SafePost testwarning
162System Options Not SetConfiguration incorrect or RTC battery depletedwarning
163Time and Date Not SetInvalid time/date in CMOS; RTC battery failure or CMOS jumper loosewarning
164Memory Size ErrorMemory configuration in CMOS does not match installed memoryerror
1720SMART Hard Drive Detect Imminent FailureHard drive SMART status indicates failure predictionerror
1780Disk 0 FailurePrimary hard drive not detected or not responding during POSTerror
1781Disk 1 FailureSecondary hard drive not detected or not responding during POSTerror
1782Disk Controller FailurePrimary IDE controller not responding during POSTcritical
1785Multibay incorrectly installedMultiBay IDE device detected on wrong IDE controller during POSTerror
1790Disk 0 ErrorPrimary disk error detected during POSTerror
1791Disk 1 ErrorSecondary disk error detected during POSTerror
1792Secondary Disk Controller FailureSecondary IDE controller not responding during POSTcritical
1793Secondary Controller or Disk FailureSecondary IDE channel error detected during POSTcritical
1794Inaccessible devices attached to primary IDE controllerPrimary IDE devices inaccessible when SATA set to Replace Primary IDE Controllererror
1800Temperature AlertInternal temperature exceeds specificationwarning
1801Microcode Patch ErrorInstalled processor not supported by current BIOS during POSTerror
1802Processor Not SupportedInstalled processor not compatible with system boarderror
1803BIOS Update Needed for ProcessorCurrent BIOS revision does not support installed processorerror
183Invalid Processor Jumper SettingProcessor speed or bus speed jumpers do not match installed processorerror
1998Master Boot Record has been changedCurrent MBR does not match previously saved copywarning
201Memory ErrorRAM failure detected during POST memory testerror
202Memory Type MismatchInstalled memory modules do not match each othererror
207ECC Corrected Single Bit Errors in Memory SocketSingle-bit ECC error detected and corrected by memory controllerwarning
212Failed ProcessorProcessor fails to initialize during POSTcritical
213Incompatible memory Module in memory SocketMemory module lacks critical SPD data or is chipset incompatibleerror
214DIMM Configuration WarningMemory DIMMs not paired correctly for dual-channel configurationwarning
215Memory Mismatch WarningMismatched DIMM pairs between channels A and Bwarning
216Memory Size Exceeds Maximum SupportedTotal installed memory exceeds system maximum capacitywarning
219ECC Memory Module DetectedECC memory installed on non-ECC platformwarning
2 red blinks, 2 beepsThermal shutdown has occurredProcessor temperature exceeds safe operating limitunknown
301Keyboard ErrorKeyboard not responding or not properly connectederror
303Keyboard Controller ErrorI/O board keyboard controller not respondingerror
304Keyboard or System Unit ErrorKeyboard not responding during POSTerror
3 red blinks, 3 beepsCPU not installedProcessor socket empty or CPU not properly seatedcritical
401Parallel Port 1 Address Assignment ConflictParallel port 1 IRQ conflicts with another devicewarning
402Parallel Port 2 Address Assignment ConflictParallel port 2 IRQ conflicts with another devicewarning
403Parallel Port 3 Address Assignment ConflictParallel port 3 IRQ conflicts with another devicewarning
404Parallel Port Address Conflict DetectedInternal and external parallel ports assigned to same addresserror
410Audio Interrupt ConflictAudio device IRQ conflicts with another devicewarning
411Network Interface Card Interrupt ConflictNetwork card IRQ conflicts with another devicewarning
4 red blinks, 4 beepsPower supply failurePower supply unable to deliver required current or voltagecritical
501Display Adapter FailureGraphics display controller not respondingerror
510Splash Screen image corruptedSplash screen image has corruption or errors in ROMinfo
511CPU Fan not detectedCPU fan not connected or not respondingwarning
512Chassis fan not detectedChassis, rear, or front fan not connected or not respondingwarning
514CPU or Chassis Fan not detectedCPU or chassis fan not responding during POSTwarning
5 red blinks, 5 beepsPre-video memory errorMemory test failure before video initializationcritical
601Diskette Controller ErrorDiskette controller or drive circuit test failureerror
605Diskette Drive Type ErrorMismatch between configured drive type and installed hardwarewarning
610External Storage Device FailureExternal tape drive not connected or not respondingwarning
611Primary Diskette Port Address Assignment ConflictDiskette port address conflict with expansion cardwarning
6 red blinks, 6 beepsPre-video graphic card errorGraphics hardware test failure before video outputcritical
7 red blinks, 7 beepsSystem board failureSystem ROM detects system board hardware failurecritical
8 red blinks, 8 beepsInvalid ROM checksumROM firmware checksum verification failscritical
912Computer Cover Has Been Removed Since Last System Start UpChassis intrusion detection triggered; cover opened since last bootinfo
914Hood Lock Coil is not ConnectedHood lock mechanism cable not connected or disconnectedwarning
916Power Button Not ConnectedPower button cable not connected to system boardwarning
917Front Audio Not ConnectedFront panel audio cable not connected to system boardinfo
918Front USB Not ConnectedFront panel USB cable not connected to system boardinfo
919MultiBay Riser Not ConnectedMultiBay riser cable not connected to system boardinfo
920Fan Command 2 Pin Connector from Power Supply Not Connected2-pin fan power connector from PSU not connected to system boardwarning
940Extended ROM signature not foundROM flash signature missing or corrupted; firmware incompletecritical
960CPU Overtemp occurredCPU temperature exceeded 95°F or thermal sensing failureerror
9 red blinks, 9 beepsSystem unable to bootSystem initialization fails after power-oncritical
ECC Multiple Bit Error Detected in Memory ModuleMultiple bit error detected in memoryChipset detects more than one bit error in 64-bit memory wordcritical
Invalid Electronic Serial NumberElectronic serial number corrupted or invalidBIOS cannot read or validate electronic serial numberwarning
LED Red solid or flashingSystem has experienced an errorAn error condition has occurred in the systemerror
None (no LED/beep)System does not power onNo power LED indication; system fails to startcritical
Parity Check 2Parity RAM failureParity error detected in memory during POSTcritical

Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI

Community

0 fixes logged by technicians through their AI, with outcomes, for this model.

ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.