GE Healthcare LOGIQ E9: troubleshooting and error codes
The ServiceForge knowledge base holds 146 documented symptoms for the GE Healthcare LOGIQ E9, with 253 ranked causes, 280 diagnostic checks with test points and expected values, and 0 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
BEP essential functions failure
One or more essential BEP functions test fails
Ranked causes
- 1. PCI Bus configuration error (unknown)
- 2. CMOS memory error (unknown)
- 3. CPU failure (unknown)
- 4. RAM failure (unknown)
- 5. Hard Drive failure or surface error (unknown)
- 6. Network interface malfunction (unknown)
6 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: DC offset for ADC channels
ADC channels require zero-output calibration when there is no signal on the input. Bias voltages are stored in Back End Processor.
Ranked causes
- 1. New LOGIQ E9 installation (common)
- 2. Software update or replacement (common)
- 3. DRX board or MRX board interchanged (occasional)
- 4. DRX board or MRX board replaced (occasional)
- 5. Back End Processor replaced (occasional)
Disconnect all connected probes
- Test point
- All probe connectors
- Expected
- Probes disconnected
8 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
High temperature reports caution
System reports elevated temperature readings on Home page
Ranked causes
- 1. System in enclosed space with heat-generating equipment (common)
- 2. Dirty fan filters (common)
- 3. Fan tray malfunction (occasional)
- 4. BEP fan not working (occasional)
- 5. GFI board failure (occasional)
System Temperature Test to compare all system temperatures to specified values
- Test point
- System temperature sensors
- Expected
- All temperatures within specified tolerance
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
System temperature out of tolerance
Temperature specifications exceed limits as shown on Home page or diagnostics
Ranked causes
- 1. Poor ventilation or equipment placement (common)
- 2. Dirty or clogged fan filters (common)
- 3. Failed fan tray (occasional)
- 4. Failed BEP fan (occasional)
- 5. Failed GFI board (rare)
Run System Temperature Test
- Test point
- All system temperature sensors
- Expected
- All temperatures within specification
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
T/R channel test failure
Transmit and Receive Channel Test fails when transmitting on one channel at a time and receiving on one channel at a time using an open probe connector.
Ranked causes
- 1. Front-plane board failure (unknown)
- 2. DRX board failure (unknown)
- 3. Analog receive signal path failure (unknown)
- 4. GRX board failure (unknown)
- 5. GRLY failure (unknown)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Transmit/receive channel test failure
T/R Channel Test fails during transmit and receive diagnostics
Ranked causes
- 1. Failed front-plane board (common)
- 2. Failed DRX board (common)
- 3. Analog receive signal path failure (common)
- 4. Failed GRX board (occasional)
- 5. Failed GRLY board (occasional)
Run T/R Channel Test with open probe connector
- Test point
- All transmit and receive channels
- Expected
- Test passes on all channels
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
4D scan fails with RAB2-5 probe
Basic 4D scan operation using RAB2-5 probe fails or does not execute
Ranked causes
- 1. RAB2-5 probe not connected to probe socket 4 (common)
- 2. Probe icon does not show correct probe type (occasional)
- 3. 4D Motor Controller not detected (occasional)
- 4. 4D Motor Controller hardware failure (occasional)
Verify RAB2-5 probe connected to probe socket 4
- Test point
- Probe socket 4
- Expected
- RAB2-5 probe fully inserted
2 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Image artifacts - pixilated or jagged edges patient safety
Digital receive signal path issues cause pixilated or jagged edges in displayed images
Ranked causes
- 1. FDEMOD signal path failure on GFI (occasional)
- 2. DRX high speed bit error (occasional)
- 3. DRX IF FPGA signal path failure (occasional)
- 4. DRX ASIC signal path failure (occasional)
Run FDEMOD Signal Test from GFI
- Test point
- GFI FDEMOD signal
- Expected
- Test passes; no errors minutes
3 more checks with pass and fail actions, 9 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Static 3D scan fails with RAB2-5 probe
Basic static 3D scan using RAB2-5 probe fails to complete or produces no image
Ranked causes
- 1. RAB2-5 probe not connected to probe socket 4 (common)
- 2. Probe icon does not show correct probe type (occasional)
- 3. 4D Motor Controller not detected by system (occasional)
- 4. 4D Motor Controller hardware failure (occasional)
Verify RAB2-5 probe is connected to probe socket 4
- Test point
- Probe socket 4 (right-most)
- Expected
- RAB2-5 probe fully inserted
2 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System shuts down immediately after power loss/interruption
Extended Power Shutdown (EPS) or Charge Board (CB) failure; system cannot maintain operation during power interruption.
Ranked causes
- 1. Extended Power Shutdown detection failure (I/O board communication) (common)
- 2. Extended Power Shutdown voltage supply failure (common)
- 3. Extended Power Shutdown battery discharged or failed (occasional)
- 4. Extended Power Shutdown charge state detection failure (occasional)
Extended Power Shutdown Detection Test
- Test point
- BEP to EPS communication via I/O board
- Expected
- Detection successful
3 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System will not scan high voltage
Transmit power supply not providing scanning capability
Ranked causes
- 1. Transmit Power Supply voltage out of specification (common)
- 2. Transmit Power Supply watchdog failure (occasional)
- 3. Transmit Power Supply fault detection failure (occasional)
- 4. Communication loss between BEP and power supply (occasional)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
3D triangulation position is off/wrong
bayBIRD 3D tracking system position or calibration error affecting ultrasound probe tracking accuracy.
Ranked causes
- 1. Sensor (transducer) malfunction or poor signal (common)
- 2. bayBIRD main unit failure (occasional)
- 3. RF/EMI interference (occasional)
Run Sensor 1 test
- Test point
- bayBIRD Sensor 1
- Expected
- Test passes
5 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
3D triangulation position offset or incorrect
bayBIRD 3D position tracking reports wrong location
Ranked causes
- 1. Sensor/transducer port malfunction (common)
- 2. Transducer failure (occasional)
- 3. bayBIRD board failure (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
4D dynamic scan test fails with RAB2-5 probe
4D Test fails when RAB2-5 probe is connected to probe socket 4; system cannot perform real-time 4D volumetric acquisition.
Ranked causes
- 1. RAB2-5 probe not connected to probe socket 4 or probe not recognized (common)
- 2. 4D Motor Controller not detected or communicating (occasional)
- 3. 4D Motor Controller board hardware failure (rare)
Verify RAB2-5 probe in socket 4 with icon check
- Test point
- Probe socket 4 and touch panel display
- Expected
- RAB2-5 probe connected to socket 4, correct icon on panel, no red arrow
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
4D Motor Controller not detected
System fails to detect presence of 4D Motor Controller or 4D probe; red arrow appears in probe icon
Ranked causes
- 1. USB connection between Host and Main Power Supply loose or disconnected (common)
- 2. 4D Motor Controller connections in Main Power Supply loose or disconnected (common)
- 3. 4D Motor Controller hardware failure (occasional)
Verify USB connection between Host and Main Power Supply
- Test point
- USB connector on Main Power Supply
- Expected
- Cable firmly seated and connected
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
BEP motherboard or system bus failure
Essential system board tests fail; CPU, RAM, CMOS, or PCI bus configuration errors detected.
Ranked causes
- 1. Motherboard harness connection failure (common)
- 2. Motherboard failure (occasional)
- 3. BEP unit failure (rare)
Run Essential Tests on BEP
- Test point
- PCI Bus, CMOS, CPU, RAM, Hard Drive, Network Interface
- Expected
- All tests pass
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: DC Offset
ADC channels of GRX inputs require calibration to ensure zero output when no signal is present. Bias voltages stored in Back End Processor.
Ranked causes
- 1. New LOGIQ E9 installation or system update (common)
- 2. DRX board interchange or replacement (common)
- 3. Back End Processor replacement (occasional)
Disconnect all probes from system
- Test point
- Probe connectors
- Expected
- All probes disconnected
6 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Electromagnetic interference (EMI) detected caution
Noise or interference on ultrasound display or data; EMI from external sources affecting system performance
Ranked causes
- 1. Medical lasers, scanners, cauterizing guns nearby (common)
- 2. Computers, monitors, fans, gel warmers, microwave ovens, light dimmers, portable phones nearby (common)
- 3. Broadcast station or broadcast van nearby (occasional)
Identify EMI sources in environment
- Test point
- System location and vicinity
- Expected
- List of potential EMI sources compiled
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
FPGA version read failure
System fails to read FPGA version on one or more boards
Ranked causes
- 1. Host-to-GFI connection issue (common)
- 2. DRX board failure (occasional)
- 3. GTX board failure (occasional)
Run FPGA Versions test
- Test point
- All FPGA devices (Host, GFI, DRX, GTX)
- Expected
- All FPGA versions read successfully
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Hard disk drive test failures
Hard Disk Drive Quick Test fails; system reports errors in essential HDD functions during diagnostic execution
Ranked causes
- 1. Hard disk drive fragmentation (common)
- 2. Hard disk drive surface defects (occasional)
- 3. Hard disk drive failure (occasional)
Execute Hard Disk Drive Quick Test
- Test point
- Diagnostics window Status portion
- Expected
- All tests pass with no failures reported
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
I/O Board audio channels not functioning
Test of all audio channels on I/O board fails
Ranked causes
- 1. BEP to Backplane cable improperly connected or faulty (common)
- 2. GFI board malfunction (occasional)
- 3. I/O Board failure (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
I/O Board GFI Temperature test fails caution
Temperature sensors on GFI board read values outside specified limits; thermal condition abnormal
Ranked causes
- 1. BEP to Backplane cable improperly connected or faulty (common)
- 2. Front-end card rack cooling fans faulty (occasional)
- 3. GFI board faulty (occasional)
Verify BEP to Backplane cable connection
- Test point
- BEP to Backplane connector
- Expected
- Cable fully seated and secure on both ends
3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
I/O Board USB communication failure
USB communications with I/O Board fails during loop back test
Ranked causes
- 1. USB cable/connections improperly connected (common)
- 2. Faulty USB cable or device (occasional)
- 3. I/O Board failure (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Intermittent system problems or communication errors in memory subsystem
Unpredictable system behavior or intermittent failures indicating memory or communication path degradation
Ranked causes
- 1. GFI board memory or internal/external RAM failure (occasional)
- 2. DRX board FPGA memory failure (occasional)
- 3. DRX board Nathan ASIC memory failure (occasional)
Run GFI Memory Access Test
- Test point
- GFI board RAM
- Expected
- Test pass
- Tools
- Diagnostics software
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Interrupted scanning
Ultrasound scanning starts but stops unexpectedly or is intermittent
Ranked causes
- 1. Transmit Power Supply watchdog failure (occasional)
- 2. Transmit Power Supply alarm/fault detection failure (occasional)
- 3. Communication error between BEP and power supply (occasional)
Run TxPs Watchdog Test diagnostic
- Test point
- Power supply watchdog function
- Expected
- Watchdog functioning and communication active
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Patient I/O data acquisition fails or no signal detected patient safety
Patient I/O Test fails; system cannot acquire ECG, PHONO (PCG) or AUX signal data from Patient I/O Module via GFI connection. Test displays no minimum/maximum/mean signal values.
Ranked causes
- 1. GFI (Generic Formatting Interface) connection fault or GFI module failure (common)
- 2. Patient I/O module hardware failure (occasional)
- 3. ECG/PHONO/AUX lead degradation or connection issues (occasional)
Run GFI diagnostic tests
- Test point
- Service Diagnostics GFI test menu
- Expected
- All GFI tests pass without errors
3 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Patient I/O test fails
Patient I/O Module fails to acquire and transmit signal data from ECG, PHONO, or AUX inputs to Host via GFI
Ranked causes
- 1. GFI connection or communication failure (common)
- 2. Patient I/O module hardware failure (occasional)
- 3. Faulty ECG leads or input cable (occasional)
Run GFI diagnostic tests
- Test point
- Service Diagnostics / GFI
- Expected
- GFI tests pass
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Primary or secondary monitor not detected
Video Status test fails; monitor not detected by I/O or displays no video
Ranked causes
- 1. BEP to Backplane cable improperly connected or faulty (common)
- 2. Monitor failure (occasional)
- 3. Monitor hardware defect (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Static 3D scan test fails with RAB2-5 probe
Static 3D Test fails when RAB2-5 probe is connected to probe socket 4 (rightmost socket); system cannot acquire 3D data.
Ranked causes
- 1. RAB2-5 probe not connected to correct probe socket (common)
- 2. 4D Motor Controller not detected by system (occasional)
- 3. 4D Motor Controller board hardware failure (rare)
Verify RAB2-5 probe connected to socket 4
- Test point
- Probe socket 4 (rightmost socket) connector
- Expected
- RAB2-5 probe fully seated in socket 4, no probe connected to other sockets
3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System Board tests fail
PC Motherboard essential functions test fails
Ranked causes
- 1. Motherboard harness improperly connected or faulty (common)
- 2. Motherboard failure (occasional)
- 3. BEP failure (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Trackball input not responding
Trackball fails diagnostic test; mouse pointer does not respond to trackball movement or clicks
Ranked causes
- 1. Trackball signal cable disconnected or loose (common)
- 2. Trackball contamination or debris (common)
- 3. Trackball hardware failure (occasional)
Execute Trackball diagnostic test
- Test point
- Diagnostics window Status portion
- Expected
- All trackball movements and clicks registered correctly
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Trackball test failures or unresponsive cursor
Trackball test fails; cursor does not respond to trackball movement or signal is weak
Ranked causes
- 1. Loose or disconnected trackball signal cable (common)
- 2. Trackball contamination or mechanical wear (common)
- 3. Trackball hardware failure (occasional)
Verify trackball signal cable connection
- Test point
- Trackball connector at rear of system
- Expected
- Cable seated firmly with no visible damage
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
4D Motor Controller not detected or communicating
4D Motor Controller Presence Test fails; system cannot detect controller or communicate via USB connection to Main Power Supply.
Ranked causes
- 1. USB connection between Host and Main Power Supply disconnected or faulty (common)
- 2. 4D Motor Controller hardware failure (occasional)
Verify USB connection between Host and Main Power Supply
- Test point
- USB connector at Host and Main Power Supply
- Expected
- Cable fully seated, no visible damage, connections secure
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
4D Motor Controller version query fails
4D Motor Controller Version Test fails; system cannot retrieve firmware or version information from controller.
Ranked causes
- 1. USB communication link fault between Host and Main Power Supply (common)
- 2. 4D Motor Controller firmware corrupt or outdated (occasional)
Verify USB connection and controller seating
- Test point
- USB cable and 4D Motor Controller connector
- Expected
- USB cable fully seated, controller fully inserted and latched in Main Power Supply
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Analog receive signal failure (high gain)
Analog RX Test with high (peak) gain fails during receive testing
Ranked causes
- 1. Failed DRX board (block of 8 dead channels indicates failure) (common)
- 2. Failed GRX board (occasional)
Run Analog RX Test (High Gain)
- Test point
- GRX board signal path at high (peak) gain
- Expected
- All channels passing with correct signal levels
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Analog receive signal failure (low gain)
Analog RX Test with low gain fails during receive testing
Ranked causes
- 1. Failed DRX board (block of 8 dead channels indicates failure) (common)
- 2. Failed GRX board (occasional)
Run Analog RX Test (Low Gain)
- Test point
- GRX board signal path at low gain
- Expected
- All channels passing with correct signal levels
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Analog receive signal failure (medium gain)
Analog RX Test with medium gain fails during receive testing
Ranked causes
- 1. Failed DRX board (block of 8 dead channels indicates failure) (common)
- 2. Failed GRX board (occasional)
Run Analog RX Test (Medium Gain)
- Test point
- GRX board signal path at medium gain
- Expected
- All channels passing with correct signal levels
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Audio system no sound output
Speaker test produces no output; beep button does not sound; left and right channels silent
Ranked causes
- 1. Speaker failure or disconnection (common)
- 2. Audio driver or sound card configuration issue (occasional)
Test recorded message playback
- Test point
- Left Front and Right Front speakers
- Expected
- Recorded message audible from each speaker
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Calibration: Advanced LCD color adjustments caution
Fine-tuning of LCD color parameters including color brightness, contrast, color temperature, gamma, and RGB gain when standard adjustments are insufficient
Ranked causes
- 1. Color or grayscale performance requires advanced adjustment (rare)
- 2. Screen position or size adjustment needed (occasional)
Access Advanced Menu
- Test point
- LCD monitor front panel mode button
- Expected
- Advanced Menu displayed with options: Screen, Color, Others, Information, Language, Exit
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DVR board communication or function failure
Digital Video Recorder (DVR) board not responding, version check fails, or self-test error detected.
Ranked causes
- 1. DVR board seating or connector issue (common)
- 2. DVR board failure (occasional)
DVR Version Test
- Test point
- DVR board communication
- Expected
- Version read successfully
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
DVR Board self test failure
DVR self test execution fails to complete successfully
Ranked causes
- 1. DVR Board seating issue (common)
- 2. DVR Board failure (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
DVR Board version read failure
DVR Version Test fails to read current DVR board version
Ranked causes
- 1. DVR Board seating issue (common)
- 2. DVR Board failure (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
GTX high speed bit error
GTX High Speed Bit Error Test fails during transmit diagnostics
Ranked causes
- 1. Failed GTX board high-speed serial interface (common)
- 2. GFI-to-GTX interface failure (occasional)
Run GTX High Speed Bit Error Test
- Test point
- GTX high-speed serial interface
- Expected
- Test passes without bit errors
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Hard disk test continues to fail after defragmentation
Quick Test fails, defragmentation is attempted, but failures persist
Ranked causes
- 1. Surface defects on hard disk (common)
- 2. Defective hard disk requiring replacement (occasional)
Defragment hard disk
- Test point
- Disk Defragmenter utility
- Expected
- Defragmentation completes without errors
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
I/O Board Self Test fails caution
Processor on I/O Board fails self-check of basic functions; board integrity compromised
Ranked causes
- 1. BEP to Backplane cable improperly connected or faulty (common)
- 2. I/O Board faulty (common)
Verify BEP to Backplane cable connection
- Test point
- BEP to Backplane connector
- Expected
- Cable fully seated and secure on both ends
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Illegal waveform transmit error
Tx P6 Illegal Waveform Test fails when illegal waveform is transmitted
Ranked causes
- 1. Failed GTX board transmit path (common)
- 2. GFI-to-GTX interface failure (occasional)
Run Tx P6 Illegal Waveform Test
- Test point
- GTX transmit path error registers
- Expected
- Error registers show valid error response to illegal waveform
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Image artifacts - pixelated or jagged edges
Display shows pixelated or jagged edges in ultrasound image; indicates signal path degradation in receive path
Ranked causes
- 1. DRX board high-speed bit error or FPGA failure (occasional)
- 2. GFI interface issue with DRX (rare)
Run DRX High Speed Bit Error Test
- Test point
- DRX board output
- Expected
- Test pass
- Tools
- Diagnostics software
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Image artifacts with channel failure or noise
Image artifacts appear with channel failure or noise detected during Analog Receive testing.
Ranked causes
- 1. DRX board channel failure (common)
- 2. GRX board failure (occasional)
Run Analog RX Test at high gain
- Test point
- GRX boards signal path
- Expected
- Test passes with no dead channels
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Image noise
Excessive noise visible in ultrasound images
Ranked causes
- 1. High environmental noise floor (common)
- 2. Analog receive chain malfunction (occasional)
Noise Floor Test to measure system noise floor from IQ data without signal
- Test point
- System IQ data receiver
- Expected
- Noise floor within acceptable limits
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Image noise or artifacts
System displays image noise, artifacts, poor image quality, or missing channels
Ranked causes
- 1. High environmental noise floor (common)
- 2. Analog receive signal path failure (common)
Run Noise Floor Test
- Test point
- System IQ data path
- Expected
- Noise floor within acceptable range
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Intermittent general problems or communication errors
Communication issues between DRX and GFI; may manifest as system instability or test failures during diagnostic operation
Ranked causes
- 1. FDEMOD Signal Test failure - PCIe cable or GFI board defect (occasional)
- 2. DRX board failure or interface issue (occasional)
Run FDEMOD Signal Test from Digital Receive diagnostics
- Test point
- Fixed Demod on GFI
- Expected
- Test pass
- Tools
- Diagnostics software
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Network adapter communication failure
Network Interface test fails or network connectivity unavailable; system cannot communicate with network
Ranked causes
- 1. Network connection not established (common)
- 2. Network adapter driver or firmware issue (occasional)
Verify physical network connection
- Test point
- Network cable connector at system and wall jack
- Expected
- Cable firmly seated; network link LED illuminated on adapter
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System comes up in simulator mode caution
System does not boot to normal operation mode; GFI voltage levels out of specification preventing front-end communication
Ranked causes
- 1. GFI voltage out of specification (common)
- 2. GFI faulty (occasional)
Run I/O Board GFI Voltage Test
- Test point
- Service Diagnostics / I/O Board Tests / I/O Board GFI Voltage Test
- Expected
- All GFI voltages within specified values
1 more check with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System voltage out of tolerance
System voltage specifications exceed limits during diagnostics
Ranked causes
- 1. Voltage out of tolerance on system boards (common)
- 2. Power supply failure or out of tolerance (occasional)
Run System Voltage Test
- Test point
- All system voltage test points
- Expected
- All voltages within specification
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
V Nav Issues or poor tracking
bayBIRD V Nav functionality degraded or unavailable; probe position tracking inaccurate or unstable.
Ranked causes
- 1. Tracking sensor malfunction (common)
- 2. bayBIRD system failure (occasional)
Run bayBIRD Run All Tests
- Test point
- All bayBIRD subsystems
- Expected
- All tests pass
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Video card test failures
Video Card test reports errors in video memory, graphics acceleration, or text output during diagnostic execution
Ranked causes
- 1. Video card defect (common)
- 2. Back-end processor (BEP) failure (occasional)
Execute Video Card diagnostic test with 18 test patterns
- Test point
- Monitor display during test execution
- Expected
- All patterns display correctly; no errors detected in Status portion
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Voltage specifications out of tolerance high voltage
System voltage readings exceed acceptable tolerance limits
Ranked causes
- 1. Board voltage out of specification (common)
- 2. Power supply voltage out of specification (occasional)
System Voltage Test to compare all system voltages to specified values
- Test point
- System voltage test points and boards
- Expected
- All voltages within specified tolerance
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Analog CW Doppler GRX ADC Digital LVDS test failure
Service diagnostic test for analog-to-digital converter digital link integrity on GRX board fails; ADC test pattern transmission or I-/Q-data sample values corrupted.
Ranked causes
- 1. CW GRX board ADC or digital link component failure (common)
Verify GFI Tests pass
- Test point
- GFI test suite
- Expected
- All GFI tests pass
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Analog CW Doppler GRX Beam Forming test failure
Service diagnostic test for beam forming phase setup on GRX board fails; amplitude deviation detected indicating phase setup error.
Ranked causes
- 1. CW GRX board phase setup malfunction (common)
Verify GFI Tests pass
- Test point
- GFI test suite
- Expected
- All GFI tests pass
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Analog CW Doppler GRX BP Filter/Mixer Clock test failure
Service diagnostic test for band pass filter and mixer clock combinations on GRX board fails; fdop, spectrum peak, RMS parameters out of tolerance.
Ranked causes
- 1. CW GRX board filter or mixer clock component failure (common)
Verify GFI Tests pass
- Test point
- GFI test suite
- Expected
- All GFI tests pass
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
More symptoms
- Analog CW Doppler GRX Dither Injection test failure
- Analog CW Doppler GRX Doppler LPF test failure
- Analog CW Doppler GRX Dual Channel test failure
- Analog CW Doppler GRX IQ Symmetry test failure
- Analog CW Doppler GRX Mixer Clock Sync test failure
- Analog CW Doppler GRX Mixer Phase Setup test failure
- Analog CW Doppler GRX Pedof test failure
- Analog CW Doppler GRX Post Mixer Gain test failure
- Audio output test failure
- Calibration: AE Title and Port settings verification
- Calibration: Functional checks after software reload
- Calibration: LCD monitor brightness adjustment
- Calibration: LCD monitor brightness and contrast
- Calibration: LCD monitor contrast adjustment
- Calibration: Patient Archive and System Configurations restore verification
- Calibration: Software option key settings verification
- Calibration: Software version verification
- Calibration: System settings documentation
- Calibration: TCP/IP settings verification
- Calibration: Video and DVR settings verification
- Calibration: Vital Product Data verification and update
- Calibration: XY lock adjustment for park lock
- Calibration: XY locking mechanism adjustment
- Calibration: XY manual lock release
- Calibration: XY manual release for lock and brake mechanism
- Calibration: Z mechanism manual repositioning
- DC offset calibration required
- DC Offset Calibration required after DRX board replacement or movement
- Diagnostic utility freezes or times out
- DICOM connectivity issue
- Documentation not accessible
- Encoder button not responding
- Encoder position not updating
- Footswitch unresponsive or misregistering
- Front End card rack fan failure
- GFI analog circuitry failure
- GFI board signal path failure
- GFI FPGA version read failure
- GFI Front End Interface failure
- GFI GTX communication failure
- GFI memory access failure
- GRX aCW Beam Forming test failure
- GRX aCW BP Filter / Mixer Clk test fails
- GRX aCW Dither Injection test fails
- GRX aCW Doppler LPF test fails
- GRX aCW Dual Channel test failure
- GRX aCW IQ Symmetry test fails
- GRX aCW Mixer Clock Sync test fails
- GRX aCW Pedof test fails
- GRX aCW Post Mixer Gain test fails
- GRX ADC Digital LVDS test fails
- GRX Mixer Phase Setup test fails
- GTX memory failure
- Hard disk drive failure or surface defect
- Hard disk test failures
- I/O Board power supply voltages out of specification
- Image artifacts
- Keyboard key response not registered
- Keyboard key unresponsiveness
- LCD Monitor installation and leveling
- LED not illuminating
- Marking log file events for analysis
- Memory test failures
- Network traffic analysis for DICOM connectivity issues
- No audio output
- No display on monitor
- No doppler audio or system audio
- Operator Panel Knobs replacement
- Probe Holder Insert replacement
- Pushbutton not responding
- Relay LVDS connection failure
- Remote access unavailable
- Scan unexpectedly stops
- Slidepot LED not illuminating
- Slidepot position not updating
- System malfunction requiring diagnostic log capture
- System performance reduced
- System starts in simulator mode
- System voltage warning messages
- Touch panel calibration error
- Touchscreen calibration required or incorrect
- Touchscreen calibration verification failing
- Touchscreen not responding
- Trackball pointer position not updating
- Trackball select buttons not responding
- WLAN dongle installation and configuration
86 more symptoms with ranked causes and checks are in ServiceForge. Connect ServiceForge to your AI
Community
0 fixes logged by technicians through their AI, with outcomes, for this model.
ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.