GE Healthcare HP XW8200: troubleshooting and error codes
The ServiceForge knowledge base holds 157 documented symptoms for the GE Healthcare HP XW8200, with 274 ranked causes, 255 diagnostic checks with test points and expected values, and 81 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
Sound does not come out of speaker or headphones
No audio output from speakers or headphones
Ranked causes
- 1. Software volume control turned down (common)
- 2. External speakers not turned on (common)
- 3. External speakers plugged into wrong audio jack (occasional)
- 4. Audio cable not connected between CD/DVD-ROM and system board (occasional)
- 5. Digital CD audio not enabled (occasional)
- 6. Headphones or external speakers mute internal speaker (occasional)
- 7. Volume is muted (occasional)
- 8. Computer in Hibernate mode (occasional)
8 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Unable to connect to the Internet
Workstation cannot establish connection to Internet or access network resources
Ranked causes
- 1. ISP account not set up properly (occasional)
- 2. Modem not set up properly (common)
- 3. Web browser not set up properly (occasional)
- 4. Cable or DSL modem not plugged in (common)
- 5. Cable or DSL service is unavailable or interrupted (occasional)
- 6. CAT5 10/100 cable is disconnected (common)
- 7. IP address not configured properly (occasional)
- 8. Cookies are corrupted (rare)
9 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Blank screen with no video output high voltage
Monitor displays no image or video output from workstation
Ranked causes
- 1. Cable connections not correct (common)
- 2. Monitor is turned off (common)
- 3. Screen blanking utility installed or energy saver enabled (common)
- 4. System ROM is bad; running in FailSafe Boot Block mode (rare)
- 5. Fixed-sync monitor will not sync at chosen resolution (occasional)
- 6. Computer is in Hibernate mode (occasional)
- 7. Monitor settings in workstation not compatible with monitor (occasional)
Verify monitor power and cable connections
- Test point
- Monitor power cable and video cable connectors
- Expected
- Both cables firmly connected to monitor and workstation and to working outlet
3 more checks with pass and fail actions, 7 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Diskette drive cannot write to diskette
System prevents writing data to diskette or write operations fail
Ranked causes
- 1. Diskette is not formatted (common)
- 2. Diskette is write-protected (common)
- 3. Writing to wrong drive (occasional)
- 4. Not enough space on diskette (common)
- 5. Diskette write control enabled (occasional)
- 6. Diskette is damaged (occasional)
Verify write protection status
- Test point
- Diskette write-protect tab
- Expected
- Tab absent or in unprotected position
1 more check with pass and fail actions, 6 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
New device not recognized as part of system
Newly installed hardware is not detected or recognized by workstation
Ranked causes
- 1. Device not seated or connected properly (common)
- 2. Cables of external device loose or power cables unplugged (common)
- 3. Power switch of external device not turned on (occasional)
- 4. Configuration changes not accepted (occasional)
- 5. PnP board not auto-configuring due to resource conflict (occasional)
- 6. Device hardware not properly jumpered or configured (occasional)
6 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
System does not power on caution
Power LED off, no lights or sounds on front panel
Ranked causes
- 1. Power button not pressed or AC supply disconnected (common)
- 2. Power supply not connected to AC outlet or cables disconnected (common)
- 3. Power button harness disconnected (occasional)
- 4. Power supply failure (occasional)
- 5. Expansion card failure (occasional)
- 6. System board failure (rare)
Verify AC power connection
- Test point
- AC outlet
- Expected
- Power outlet has power
4 more checks with pass and fail actions, 8 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Diagnostics reports network failure
Network diagnostic test fails to complete or reports error condition
Ranked causes
- 1. Cable is not securely connected (common)
- 2. Cable is attached to incorrect connector (common)
- 3. Problem with cable or remote device (occasional)
- 4. Network controller interrupt shared with expansion board (occasional)
- 5. Network controller is defective (rare)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Keyboard commands and typing not recognized
Keyboard input fails to register on workstation
Ranked causes
- 1. Keyboard connector not properly connected (common)
- 2. Program in use stopped responding to commands (occasional)
- 3. Keyboard needs repairs (rare)
- 4. Keyboard key is stuck down (occasional)
- 5. Workstation in Hibernate mode (occasional)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
USB device, headphone, or microphone not recognized
Workstation does not detect or recognize connected USB device, headphones, or microphone
Ranked causes
- 1. Device not properly connected (common)
- 2. USB device does not have power (occasional)
- 3. Correct device driver not installed (occasional)
- 4. Cable from device to computer does not work (occasional)
- 5. Device is not working (rare)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cannot boot to diskette
System fails to boot from diskette, boots to hard drive instead
Ranked causes
- 1. Diskette is not bootable (common)
- 2. Diskette boot disabled in Computer Setup (common)
- 3. Removable media boot disabled in Computer Setup (common)
- 4. Diskette MBR validation is enabled (occasional)
Verify diskette is bootable
- Test point
- Bootable diskette
- Expected
- Diskette contains boot sector and system files
1 more check with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Diskette drive cannot read diskette
System unable to read data from diskette or access diskette contents
Ranked causes
- 1. Diskette is not formatted (common)
- 2. Wrong diskette type for drive type (common)
- 3. Reading wrong drive (occasional)
- 4. Diskette is damaged (occasional)
Verify correct diskette type for drive
- Test point
- Drive specifications and diskette type
- Expected
- Diskette type matches drive specifications
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Diskette drive light stays on
Diskette drive activity indicator remains illuminated continuously
Ranked causes
- 1. Diskette is damaged (occasional)
- 2. Diskette incorrectly inserted (common)
- 3. Files on diskette are damaged (occasional)
- 4. Drive cable not properly connected (occasional)
Verify diskette insertion
- Test point
- Diskette drive
- Expected
- Diskette properly seated in drive
1 more check with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Mouse does not respond to movement or is too slow
Mouse movement is unresponsive or sluggish
Ranked causes
- 1. Mouse connector not properly plugged in (common)
- 2. Program in use stopped responding to commands (occasional)
- 3. Mouse needs repairs (rare)
- 4. Workstation in Hibernate mode (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Network status link light does not turn on or flash
Network status indicator LED remains off or does not flash during network activity
Ranked causes
- 1. No active network is detected (common)
- 2. Network controller is not set up properly (occasional)
- 3. Network driver is not properly loaded (occasional)
- 4. System cannot autosense the network (rare)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Printer does not print
Printer fails to output documents
Ranked causes
- 1. Printer not turned on and online (common)
- 2. Correct printer driver not installed for application (common)
- 3. Not connected to printer on network (occasional)
- 4. Printer hardware failure (rare)
5 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
System does not boot or hangs during startup
System fails to complete boot process; no operating system loading or system freezes
Ranked causes
- 1. Removable media present in drives (common)
- 2. Cable connections loose or incorrect (occasional)
- 3. Non-PnP expansion board or option installed without reconfiguration (occasional)
- 4. Outdated BIOS, drivers, or software (occasional)
Remove removable media
- Test point
- Floppy drive and CD-ROM drive
- Expected
- No diskettes or CDs present
1 more check with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System fails POST with error 101
Option ROM error displayed during power-on self test; system may not complete startup
Ranked causes
- 1. System ROM checksum error (common)
- 2. Faulty expansion card recently added (occasional)
- 3. CMOS configuration issue (occasional)
- 4. Defective system board (rare)
Verify system ROM is correct and not corrupted
- Test point
- ROM
- Expected
- Valid ROM checksum
2 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Temperature alert at POST caution
Internal temperature exceeds specification; system overheating
Ranked causes
- 1. Blocked air vents or cooling fan malfunction (common)
- 2. Processor speed incorrectly configured (occasional)
- 3. Processor failure (rare)
- 4. System board failure (rare)
Check for blocked air vents
- Test point
- Workstation chassis vents
- Expected
- All vents clear and unobstructed
4 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
CD-ROM, CD-RW, DVD-ROM, or DVD-R/RW drive cannot read disc or is slow to start
Optical drive fails to read media or takes excessive time to recognize disc
Ranked causes
- 1. CD inserted upside down (common)
- 2. DVD-ROM needs time to determine media type (occasional)
- 3. CD or DVD disc is dirty (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
CPU overtemp occurred caution
POST error 960 indicates CPU temperature has exceeded maximum operating limit of 95°F due to excessive ambient temperature or cooling obstruction
Ranked causes
- 1. Ambient temperature exceeds 95°F maximum operating limit (common)
- 2. Airflow obstruction or excessive dust on heatsink/fans (common)
- 3. Thermal sensing circuitry failure on CPU or system board (rare)
Verify ambient temperature is within 95°F maximum limit
- Test point
- Environment where system operates
- Expected
- Ambient temperature at or below 95°F
4 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Device in IEEE-1394 port not responsive
Device connected to IEEE-1394 (FireWire) port does not respond or function
Ranked causes
- 1. Cables of external device loose or power cables unplugged (common)
- 2. Power switch on external device not turned on (common)
- 3. IEEE-1394 port not active or not purchased with system (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Keyboard failure or not detected
POST error 301 indicates keyboard failure, not detected, or keys pressed during startup
Ranked causes
- 1. Keyboard not connected or properly seated (common)
- 2. Key pressed during POST (occasional)
- 3. Keyboard hardware failure (rare)
Reconnect keyboard with power off
- Test point
- Keyboard connector
- Expected
- Keyboard firmly connected
3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Network controller stopped after adding expansion board
Previously working network controller fails when new expansion card is installed
Ranked causes
- 1. Network controller interrupt shared with expansion board (common)
- 2. Network controller drivers accidentally deleted (occasional)
- 3. Expansion board NIC conflicts with embedded NIC (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Network controller stops working without apparent cause
Previously functioning network controller fails unexpectedly without obvious hardware change or error message
Ranked causes
- 1. Network driver files are corrupted (common)
- 2. Cable is not securely connected (occasional)
- 3. Network controller is defective (rare)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Newly installed device not recognized
System does not automatically recognize or detect newly installed hardware
Ranked causes
- 1. Device not listed in Computer Setup - hardware problem (occasional)
- 2. Device listed in Computer Setup but not recognized - driver problem (occasional)
- 3. System did not auto-detect newly installed drive (common)
Verify device is listed in Computer Setup
- Test point
- Computer Setup device list
- Expected
- Device appears in device inventory
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Printer prints garbled information
Printer output is distorted, unreadable, or corrupted
Ranked causes
- 1. Correct printer driver not installed (common)
- 2. Cables not connected properly (occasional)
- 3. Printer memory overloaded (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
System will not boot from CD-ROM or DVD drive
Workstation fails to initiate operating system load from optical media
Ranked causes
- 1. CD-ROM or DVD boot not enabled in Computer Setup (common)
- 2. Non-bootable CD in drive (common)
- 3. CD-ROM or DVD drive not detected or driver not loaded (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Blurry video or cannot set requested resolution
Display image is blurry or resolution setting fails to apply
Ranked causes
- 1. Graphics controller upgraded without correct video drivers (common)
- 2. Monitor not capable of displaying requested resolution (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Diagnostics passes but workstation does not communicate with network
Diagnostic test succeeds but workstation cannot send or receive network traffic
Ranked causes
- 1. Network drivers not loaded or parameters mismatch (common)
- 2. Network controller not configured for this workstation (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Dim characters on display
Monitor displays text and images with reduced brightness or dim appearance
Ranked causes
- 1. Brightness and contrast controls not set properly (common)
- 2. Cables not properly connected (occasional)
Adjust monitor brightness control
- Test point
- Monitor brightness control
- Expected
- Image brightness increased to normal readable level
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Disk 0 error at POST
System reports disk 0 error during power-on self test; drive not installed correctly or failed
Ranked causes
- 1. Drive not installed correctly (common)
- 2. Drive failure (occasional)
Verify jumper settings on disk 0 drive
- Test point
- Drive jumper block
- Expected
- Jumpers correctly set per model specification
3 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Disk 1 error at POST
System reports disk 1 error during power-on self test; drive not installed correctly or failed
Ranked causes
- 1. Drive not installed correctly (common)
- 2. Drive failure (occasional)
Verify jumper settings on disk 1 drive
- Test point
- Drive jumper block
- Expected
- Jumpers correctly set per model specification
3 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Drive not found
System cannot detect or identify diskette drive during operation
Ranked causes
- 1. Cable is loose (common)
- 2. Removable drive not seated properly (common)
Verify cable connections
- Test point
- Diskette drive data and power connectors
- Expected
- Cables firmly seated
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Insufficient memory error during operation
Application or operating system reports out of memory while running
Ranked causes
- 1. Too many TSR programs installed (occasional)
- 2. Insufficient memory for application (common)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Keyboard or system unit error
POST error 304 indicates keyboard failure or system unit communication problem
Ranked causes
- 1. Keyboard failure or not properly connected (common)
- 2. System board failure (rare)
Reconnect keyboard with power off
- Test point
- Keyboard connector
- Expected
- Keyboard firmly connected
3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Master boot record changed at POST caution
Current MBR does not match previously saved MBR copy; MBR has been modified
Ranked causes
- 1. MBR modified by normal disk maintenance (fdisk, format, disk manager) (common)
- 2. Virus or malware infection (occasional)
Determine cause of MBR change
- Test point
- System history and recent activities
- Expected
- Identified whether from normal maintenance or malware
3 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Memory module failure detected
POST error 201 indicates RAM failure or incorrect installation during memory test
Ranked causes
- 1. Faulty or incorrectly installed memory module (common)
- 2. System board failure if memory replacement fails (rare)
Run Computer Setup and memory utilities
- Test point
- F10 Setup or Windows memory test
- Expected
- Memory test completes without errors
3 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Memory size configuration error
POST error 164 indicates memory configuration does not match actual installed memory
Ranked causes
- 1. Memory module not installed properly (common)
- 2. Third-party memory incompatibility (occasional)
Run Computer Setup to auto-detect memory configuration
- Test point
- F10 Setup or Windows
- Expected
- System detects all installed memory correctly
3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Movie will not play in DVD drive
DVD player cannot play movie disc or playback fails to start
Ranked causes
- 1. Movie is regionalized for different country (occasional)
- 2. Decoder software is not installed (common)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Network driver does not detect network controller
Operating system network driver fails to recognize network interface controller
Ranked causes
- 1. Network controller is disabled (common)
- 2. Incorrect or missing network driver (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Nonsystem disk/NTLDR missing message
Workstation displays 'Nonsystem disk' or 'NTLDR missing' error message during boot
Ranked causes
- 1. System trying to start from non-bootable diskette (common)
- 2. System trying to start from damaged hard drive (occasional)
Check for diskette in drive
- Test point
- Diskette drive
- Expected
- Diskette removed from drive
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Out of memory error
Operating system or application reports insufficient memory available
Ranked causes
- 1. Memory configuration not set up correctly (occasional)
- 2. Insufficient memory for application (common)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Picture broken up, rolls, jitters, or flashes
Display shows rolling, jittering or flashing distortion
Ranked causes
- 1. Monitor connections incomplete or monitor incorrectly adjusted (common)
- 2. Monitor needs degaussing (occasional)
4 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Poor performance experienced
System runs slowly or exhibits degraded responsiveness
Ranked causes
- 1. Processor is hot or thermal throttling (common)
- 2. Hard drive full (common)
Monitor CPU temperature and ensure cooling fans operate
- Test point
- Processor and cooling fan
- Expected
- Processor fan spinning and airflow not blocked
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Power LED flashes red six times with six beeps
Power LED flashes red six times with one-second intervals, followed by two-second pause; workstation beeps six times in same pattern
Ranked causes
- 1. Video card not seated properly or video card is faulty (common)
- 2. System board is faulty (occasional)
Ensure graphics card is fully seated
- Test point
- Graphics card slot
- Expected
- Card fully inserted and latched
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Second Ultra ATA hard drive performs suboptimally
Secondary UATA hard drive on same cable shows reduced performance or slower than expected speeds
Ranked causes
- 1. Using wrong cable type for drive type (occasional)
- 2. Both slow and fast UATA devices on same data cable (common)
Verify 80-conductor cable used for UATA drive
- Test point
- Secondary drive cable
- Expected
- 80-conductor cable installed
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System does not power on or respond caution
Workstation fails to start; no LED illumination or system activity
Ranked causes
- 1. Power not connected or outlet not working (common)
- 2. System not powered on (common)
Verify electrical connection
- Test point
- Power outlet and workstation/monitor plugs
- Expected
- Connections are secure and outlet is working
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System fails POST with error 102
System board failure indicated by DMA or timer error during POST
Ranked causes
- 1. DMA or timer circuit failure on system board (common)
- 2. Faulty expansion board (occasional)
Clear CMOS to attempt DMA/timer recovery
- Test point
- CMOS
- Expected
- CMOS cleared, defaults restored
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
System fails POST with error 103
System board failure indicated by DMA or timer error during POST
Ranked causes
- 1. DMA or timer circuit failure on system board (common)
- 2. Faulty expansion board (occasional)
Clear CMOS to attempt DMA/timer recovery
- Test point
- CMOS
- Expected
- CMOS cleared, defaults restored
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Time and date not set
POST error 163 indicates invalid time or date stored in configuration memory, RTC battery may be failing
Ranked causes
- 1. RTC battery failure preventing time storage (common)
- 2. CMOS jumper not properly installed (occasional)
Set date and time in system configuration
- Test point
- Control Panel or F10 Setup
- Expected
- Current date and time correctly set
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Workstation powers off with red LED flashing caution
System automatically powers off and Power LED flashes red twice per second with two-second pauses, accompanied by beeping
Ranked causes
- 1. Processor thermal protection activated - fan blocked or not turning (common)
- 2. CPU heatsink fan assembly not properly attached (common)
Check if air vents are blocked
- Test point
- Workstation air vents
- Expected
- Vents clear and unobstructed
2 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Workstation will not start
Workstation fails to power up or boot
Ranked causes
- 1. Wrong memory modules or incorrect installation (common)
- 2. PCI Express power cable plugged into wrong connector (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Audio interrupt conflict
POST error 410 indicates IRQ address conflicts with another device on audio subsystem
Ranked causes
- 1. Audio IRQ address conflicts with another device (common)
Reset audio subsystem IRQ assignment
- Test point
- BIOS setup or system configuration
- Expected
- Audio IRQ reassigned without conflict
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
BIOS update needed for processor at POST
Installed processor not supported by current BIOS revision
Ranked causes
- 1. BIOS version too old for installed processor (common)
Identify current BIOS version
- Test point
- BIOS Setup display or boot screen
- Expected
- Current BIOS revision number noted
2 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cannot automatically launch Internet programs
Internet applications fail to start or do not launch when expected
Ranked causes
- 1. Must log on to ISP before programs will start (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cannot connect to network server during Remote System Installation
Workstation fails to establish connection to Remote System Installation server or network boot environment
Ranked causes
- 1. Network controller not configured properly (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cannot eject compact disc from tray-load unit caution
CD-ROM or DVD tray will not open or eject button does not function
Ranked causes
- 1. Disc not properly seated in drive (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cannot format diskette
System unable to complete diskette formatting operation
Ranked causes
- 1. Invalid media - diskette capacity not specified (common)
Format diskette with capacity specification
- Test point
- MS-DOS command line
- Expected
- Diskette formatted successfully
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Chassis fan not detected caution
POST error 512 indicates chassis or case fan is not connected or has malfunctioned
Ranked causes
- 1. Chassis fan cable not connected or fan malfunctioned (common)
Reseat chassis fan cable connection
- Test point
- Fan connector on system board
- Expected
- Fan cable firmly connected
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Computer cover has been removed
POST error 912 indicates computer access panel has been removed since last system start
Ranked causes
- 1. Computer cover removed since last startup (common)
More symptoms
- CPU fan not detected
- CPU or chassis fan not detected
- Cursor will not move using arrow keys on keypad
- DIMM configuration error
- Disk 0 failure
- Disk 1 failure
- Disk controller failure
- Disk transaction problem
- Diskette controller error
- Diskette drive type mismatch
- Diskette error occurred
- Display works during POST but goes blank when OS starts
- Drive jumper settings incorrect
- Drive not found (hard drive)
- Drive responds slowly after power-up
- ECC memory module detected on unsupported platform
- ECC multiple bit error detected in memory at POST
- ECC single bit memory error
- Extended ROM signature not found
- External storage device failure
- Fan connector from power supply not connected
- Front audio not connected
- Front USB not connected
- Fuzzy focus, streaking, ghosting, shadowing, or horizontal scrolling lines
- Game port address conflict
- Graphics adapter failure
- Hard drive boot disabled in Computer Setup
- Hard drive error occurs
- Hood lock coil not connected
- IDE (ATA) controller disabled
- Inaccessible devices on primary IDE controller at POST
- Incompatible memory module detected
- Insufficient memory for Option ROMs
- Internet takes too long to download websites
- Invalid electronic serial number at POST
- Invalid processor jumper setting
- Invalid system disk message displayed
- Keyboard controller error
- Keyboard not responding to key presses
- Master boot record lost at POST
- Memory count during POST is wrong
- Memory exceeds maximum supported
- Memory mismatch between channels
- Memory module type mismatch
- Microcode patch error at POST
- MIDI port address conflict
- Monitor display is dim or not visible
- Monitor does not function with energy saver features
- Mouse will only move vertically or horizontally, or movement is jerky
- Multi-Bay riser not connected
- Multibay incorrectly installed
- Network interface card interrupt conflict
- New network card will not boot
- Noise or no sound from speakers or headphones
- Parallel port address conflict detected
- Parallel port address conflict on port 1
- Parallel port address conflict on port 2
- Parallel port address conflict on port 3
- Parity check 2 error at POST
- Poor processor performance
- Power button not connected
- Power LED flashes red five times with corresponding beeps
- Power LED flashes red five times with five beeps
- Power LED flashes red once every two seconds
- Power LED flashes red six times with beeping
- Power LED is red and stays on
- Power supply shuts down intermittently
- Primary diskette port address conflict
- Printer does not turn on
- Printer is offline
- Processor failed to initialize
- Processor not supported at POST
- Recording audio CDs is difficult or impossible
- SafePost detects unresponsive PCI card
- Secondary controller or disk failure at POST
- Secondary disk controller failure at POST
- Serial port 1 address conflict
- Serial port 2 address conflict
- Serial port address conflict on same IRQ
- SMART hard drive detects imminent failure
- SMART SCSI hard drive detects imminent failure
- Sound cuts in and out
- Splash screen image corrupted
- System audio address conflict
- System configuration not set
- System files missing or not properly installed
- System has error or shows red LED
- System setup utility reports unprogrammed EEPROM
- System will not boot or does not function properly after installing additional memory
- USB, audio, and IEEE-1394 devices not working
- Wake-on-LAN feature not functioning
- Workstation appears locked up and will not turn off
- Workstation appears to pause periodically
- Workstation date and time display is incorrect
- Workstation locked up while recording audio
- Workstation powered off automatically with red LED flashes
- Workstation seems to be locked up
97 more symptoms with ranked causes and checks are in ServiceForge. Connect ServiceForge to your AI
Error codes
| Code | Meaning | Trigger | Severity |
|---|---|---|---|
101 | Option ROM Error | System ROM checksum validation failure during POST | error |
102 | System Board Failure | DMA or timer circuit failure detected during POST | error |
103 | System Board Failure | DMA or timer circuit failure detected during POST | error |
110 | Out of Memory for Option ROMs | Option ROM unable to run due to memory constraints during POST | warning |
1151 | Serial Port 1 Address Conflict Detected | Both external and internal serial ports assigned to COM1 address | error |
1152 | Serial Port 2 Address Conflict Detected | Both external and internal serial ports assigned to COM2 address | error |
1155 | Serial Port Address Conflict Detected | External and internal serial ports assigned to same IRQ address | error |
1201 | System Audio Address Conflict Detected | Audio device IRQ address conflict detected during POST | warning |
1202 | MIDI Port Address Conflict Detected | MIDI port device IRQ address conflict detected during POST | warning |
1203 | Game Port Address Conflict Detected | Game port device IRQ address conflict detected during POST | warning |
150 | SafePost Active | PCI expansion card not responding to initialization during POST | warning |
162 | System Options Not Set | System configuration missing or RTC battery failure detected during POST | warning |
163 | Time and Date Not Set | Invalid time/date in configuration memory during POST | warning |
164 | Memory Size Error | Memory configuration does not match installed memory during POST | error |
1720 | SMART Hard Drive Detect Imminent Failure | SMART sensor reports hard drive about to fail during POST | critical |
1721 | SMART SCSI Hard Drive detects imminent failure | SCSI hard drive SMART sensor reports imminent failure during POST | critical |
1780 | Disk 0 Failure | Disk 0 not installed correctly or has failed during POST | error |
1781 | Disk 1 Failure | Disk 1 not installed correctly or has failed during POST | error |
1782 | Disk Controller Failure | Hard drive controller circuitry error detected during POST | error |
1785 | Multibay incorrectly installed | Multibay not configured as device 0 on secondary IDE controller | error |
1790 | Disk 0 error | Primary disk drive not accessible at POST | error |
1791 | Disk 1 error | Secondary disk drive not accessible at POST | error |
1792 | Secondary disk controller failure | Hard drive controller circuitry error detected at POST | error |
1793 | Secondary controller or disk failure | Secondary hard drive controller or disk error at POST | error |
1794 | Inaccessible devices on primary IDE controller | Primary IDE devices cannot be accessed when SATA controller set to Replace mode | warning |
1800 | Temperature alert | Internal temperature exceeds specification at POST | error |
1801 | Microcode patch error | Processor not supported by current ROM BIOS at POST | error |
1802 | Processor not supported | System board does not support installed processor at POST | error |
1803 | BIOS update needed for processor | Installed processor not supported by current BIOS at POST | error |
183 | Invalid Processor Jumper Setting | Processor speed jumper on system board incorrectly configured | error |
1998 | Master boot record has been changed | Current MBR differs from previously saved copy | warning |
201 | Memory Error | RAM failure detected during memory test in POST | error |
202 | Memory Type Mismatch | Installed memory modules do not match each other during POST | warning |
207 | ECC Corrected Single Bit Errors in Memory Socket(s) | ECC detected and corrected single bit error in memory during POST | warning |
212 | Failed Processor | Processor failed to initialize during POST | error |
213 | Incompatible memory Module in memory Socket(s) | Memory module missing SPD information or incompatible with chipset | error |
214 | DIMM Configuration Warning | DIMMs not installed correctly or not paired correctly during POST | warning |
215 | Memory Mismatch Warning | Mismatched DIMM pairs between channel A and channel B detected during POST | warning |
216 | Memory Size Exceeds Maximum Supported | Total installed memory exceeds system maximum supported capacity | error |
219 | ECC Memory Module Detected | ECC memory modules detected on platform that does not support ECC | warning |
301 | Keyboard Error | Keyboard failure or not detected during POST | error |
303 | Keyboard Controller Error | I/O board keyboard controller failure detected during POST | error |
304 | Keyboard or System Unit Error | Keyboard failure or system unit communication error during POST | error |
401 | Parallel Port 1 Address Assignment Conflict | IRQ address conflict detected on parallel port 1 during POST | warning |
402 | Parallel Port 2 Address Assignment Conflict | IRQ address conflict detected on parallel port 2 during POST | warning |
403 | Parallel Port 3 Address Assignment Conflict | IRQ address conflict detected on parallel port 3 during POST | warning |
404 | Parallel Port Address Conflict Detected | Both external and internal parallel ports assigned to same address | error |
410 | Audio Interrupt Conflict | Audio subsystem IRQ address conflict during POST | warning |
411 | Network Interface Card Interrupt Conflict | Network adapter IRQ address conflict during POST | warning |
501 | Display Adapter Failure | Graphics display controller failure detected during POST | error |
510 | Splash Screen image corrupted | Splash screen image has errors or corruption detected during POST | info |
511 | CPU, CPUA, or CPUB Fan not detected | CPU fan not connected or not responding during POST | warning |
512 | Chassis, rear chassis, or front chassis fan not detected | Chassis fan not connected or not responding during POST | warning |
514 | CPU or Chassis Fan not detected | CPU fan or chassis fan not connected or not responding during POST | warning |
601 | Diskette Controller Error | Diskette controller or drive circuitry failure detected during POST | error |
605 | Diskette Drive Type Error | Mismatch between configured and installed diskette drive type | error |
610 | External Storage Device Failure | External tape drive not connected or not detected during POST | warning |
611 | Primary Diskette Port Address Assignment Conflict | Diskette port address configuration error during POST | error |
912 | Computer Cover Has Been Removed Since Last System Start Up | Access panel removal detected since last system startup | info |
914 | Hood Lock Coil is not Connected | Hood lock solenoid not connected or missing during POST | warning |
916 | Power Button Not Connected | Power button connector not connected to system board during POST | warning |
917 | Front Audio Not Connected | Front audio cable not connected to system board during POST | info |
918 | Front USB Not Connected | Front USB header cable not connected to system board during POST | info |
919 | Multi-Bay Riser Not Connected | Multi-bay drive riser module not connected to system board during POST | warning |
920 | Fan Command 2 Pin Connector from Power Supply Not Connected | 2-pin fan connector from power supply not connected during POST | warning |
940 | Extended ROM signature not found | ROM flash signature missing; firmware (BIOS) incomplete during POST | error |
960 | CPU Overtemp occurred | CPU temperature exceeded maximum 95°F limit during POST | critical |
Certain typed symbols do not appear correct | Font does not support particular symbol | Typed symbol displays incorrectly or as placeholder | info |
ECC Multiple Bit Error Detected in Memory Module | Multiple bit ECC memory error detected | Chipset detected multiple bit errors in 64-bit memory quadword at POST | critical |
GREEN Power LED flashes 1 time per 2 seconds | Workstation in Standby mode | System placed in Standby sleep state | info |
GREEN Power LED solid | Workstation is on | System successfully powered on and booted | info |
Invalid Electronic Serial Number | System electronic serial number corrupted | Electronic serial number field corrupted or unreadable at POST | warning |
Parity Check 2 | Parity RAM failure | Memory parity error detected at POST | error |
Power LED off, no lights/sounds | System does not power on | Power button pressed but no response | critical |
RED LED blinks 1 time per 2 seconds | Power supply failure | Power supply unable to provide adequate power to system | error |
RED LED blinks 2 times per second | Thermal shutdown activated | Processor temperature exceeded safe threshold | error |
RED LED blinks 5 times, 5 beeps | Memory module failure detected | System detected failed memory during POST | error |
RED LED blinks 6 times, 6 beeps | Integrated graphics failure | System detected graphics subsystem failure during POST | error |
RED LED blinks 7 times, 7 beeps | System board failure before video output | System board ROM detected failure before video capability | critical |
RED LED blinks 8 times, 8 beeps | Invalid ROM based on bad checksum | ROM checksum validation failed during startup | error |
Solid RED LED | CPU not installed or not seated | Processor not detected during POST | error |
Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI
Community
0 fixes logged by technicians through their AI, with outcomes, for this model.
ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.