GE Healthcare BIS module: troubleshooting and error codes
The ServiceForge knowledge base holds 28 documented symptoms for the GE Healthcare BIS module, with 36 ranked causes, 13 diagnostic checks with test points and expected values, and 0 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
Module functionality test fails patient safety
BIS module does not function correctly; error messages appear or test DSC fails.
Ranked causes
- 1. BISx unit defective (common)
- 2. Incompatible system component (occasional)
- 3. Identical modules connected (occasional)
- 4. Defective or incompatible accessories (occasional)
- 5. Loose keypad cable or module connector problem (rare)
Verify system component compatibility
- Test point
- Monitor and all connected modules
- Expected
- All components listed in supplemental information manual
5 more checks with pass and fail actions, 5 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Sensor check failed patient safety
BIS sensor impedance check fails; one or more electrode impedances exceed acceptable threshold.
Ranked causes
- 1. Sensor improperly attached to patient (common)
- 2. Faulty sensor (occasional)
- 3. PIC+ cable or BISx unit faulty (occasional)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Sensor impedance check not available in menus
Sensor impedance check option is missing or inaccessible from monitor menu system.
Ranked causes
- 1. Sensor not connected to BISx unit (common)
- 2. BISx unit not connected to monitor module (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Testing DSC message displayed
BISx unit self-test is in progress or has been manually activated from BIS menu.
Ranked causes
- 1. BISx unit test in progress (common)
- 2. Test result is FAIL; repeat or replace unit (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Apply sensor message displayed
Message appears in parameter window indicating sensor connection to patient is loose.
Ranked causes
- 1. Loose sensor electrodes (common)
Verify sensor electrode contact with patient skin
- Test point
- BIS sensor electrodes
- Expected
- Firm contact with good impedance
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Artifact message displayed
Message in parameter or waveform window indicates signals contain noise or artifact from non-EEG data such as EMG, eye blinks, or shivering.
Ranked causes
- 1. Non-EEG artifact present (common)
Monitor signal quality and artifact levels
- Test point
- BIS waveform display
- Expected
- Artifact clears and signal quality improves
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Automatic check off message displayed
Message in parameter window indicates automatic sensor check has been turned off.
Ranked causes
- 1. Automatic sensor check disabled (unknown)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
BIS cable off message displayed
Alarm message in alarm area indicates cable is disconnected from the module.
Ranked causes
- 1. BIS cable disconnected (common)
Verify cable connection
- Test point
- BIS module connector
- Expected
- Cable firmly seated
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
BIS DSC error message displayed caution
Alarm message in alarm area indicates BISx unit is not communicating or operating properly, may occur during electrocautery use.
Ranked causes
- 1. BISx communication or operation failure (occasional)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
BIS measurement removed message displayed
Alarm message in alarm area indicates BIS module is disconnected from the module slot.
Ranked causes
- 1. BIS module disconnected from slot (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
BIS module error message displayed
Alarm message in alarm area indicates BISx unit failure.
Ranked causes
- 1. BISx unit failure (rare)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
BIS sensor check failed message displayed
Alarm message in alarm area indicates sensor check failed due to one or more electrode impedances exceeding threshold.
Ranked causes
- 1. High electrode impedance (common)
Verify electrode impedance
- Test point
- Sensor electrodes
- Expected
- All electrode impedances below threshold
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
BIS sensor expired message displayed patient safety
Alarm message in alarm area indicates sensor date has expired, sensor used too many times, validity time cannot be determined, or sensor used for more than 24 hours.
Ranked causes
- 1. Sensor expired or overused (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Cable off message displayed
Message in parameter or waveform window indicates cable is disconnected from the module.
Ranked causes
- 1. Cable disconnected (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Checking sensor message displayed
Message in parameter or waveform window indicates sensor check is in progress, either initial, manual, or periodic check.
Ranked causes
- 1. Sensor check in progress (common)
Monitor sensor check progress
- Test point
- Parameter or waveform display
- Expected
- Check completes successfully
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Checking sensor message stays longer than 2 minutes patient safety
Sensor check process does not complete within normal 2-minute timeout period.
Ranked causes
- 1. Sensor not attached to patient while connected to PIC+ cable (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Demo data message displayed
Message in parameter or waveform window indicates BIS simulator is connected.
Ranked causes
- 1. BIS simulator connected (rare)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
DSC error message displayed caution
Message in parameter window indicates BISx unit is not communicating or operating properly, may occur during electrocautery use.
Ranked causes
- 1. BISx communication or operation failure (occasional)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
High BIS impedance message displayed
Alarm message in alarm area indicates electrode impedance is too high due to sensor not being properly connected to patient.
Ranked causes
- 1. High electrode impedance from loose connection (common)
Measure electrode impedance
- Test point
- BIS sensor electrodes
- Expected
- Impedance below threshold
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Identical BIS modules message displayed
Alarm message in alarm area indicates there are two or more BIS modules in the system.
Ranked causes
- 1. Multiple BIS modules present (rare)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Incompatible DSC message displayed
Message in parameter window indicates hardware/software is not compatible with the BISx.
Ranked causes
- 1. Incompatible DSC hardware or software (rare)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Incompatible sensor message displayed patient safety
Message in parameter or waveform window indicates sensor used is not a BIS sensor or is not recognized.
Ranked causes
- 1. Non-BIS sensor or unrecognized sensor (occasional)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Module error message displayed
Message in parameter or waveform window indicates BISx unit failure.
Ranked causes
- 1. BISx unit failure (rare)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
No BIS sensor or No sensor message displayed
Alarm message in alarm area or parameter/waveform window indicates sensor is not connected to PIC+ cable or PIC+ cable is not connected to BISx unit.
Ranked causes
- 1. Sensor or PIC+ cable not connected (common)
3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
No BIS waveform displayed on screen
BIS waveform signal is not visible on monitor display; no waveform trace shown.
Ranked causes
- 1. BIS waveform not selected on display or priority too low (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Poor signal message displayed
Message in parameter or waveform window indicates artifacts or high EMG activity prevent BIS calculation, data excluded, with SQI less than 50.
Ranked causes
- 1. Low signal quality from artifact or EMG activity (common)
Measure signal quality index
- Test point
- Parameter display (SQI)
- Expected
- SQI >= 50
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Replace sensor message displayed patient safety
Message in parameter window indicates sensor date has expired, sensor used too many times, validity time cannot be determined, or sensor used for more than 24 hours.
Ranked causes
- 1. Sensor expired or overused (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Sensor impedance check fails during operation patient safety
Sensor impedance test cannot be completed or produces error result during check process.
Ranked causes
- 1. Sensor poorly attached to patient (common)
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Community
0 fixes logged by technicians through their AI, with outcomes, for this model.
ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.