ERBE EIP 2: troubleshooting and error codes

The ServiceForge knowledge base holds 8 documented symptoms for the ERBE EIP 2, with 12 ranked causes, 0 diagnostic checks with test points and expected values, and 6 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI

Symptoms

Error code E-3 displayed caution

Display shows error E-3 indicating no measurable motor current flow

Ranked causes

  1. 1. Connection between gear motor and main board interrupted (common)
  2. 2. Gear motor faulty (occasional)
  3. 3. Current measurement gain failed (rare)

3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Error code E-2 displayed caution

Display shows error E-2 indicating motor current exceeds safe limits

Ranked causes

  1. 1. Pump head faulty or damaged (common)
  2. 2. Gear motor faulty or damaged (occasional)

3 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Pump lid symbol flashes and pump cannot activate

Pump lid indicator (- n -) flashes on display; pump activation fails or stops during operation

Ranked causes

  1. 1. Pump lid not closed before activation (common)
  2. 2. Pump lid opened during activation (occasional)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Error code E 5 displayed

Display shows E 5 error code during operation.

Ranked causes

  1. 1. PIC memory altered due to ageing or radiation (occasional)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Error code E-1 displayed caution

Display shows error E-1 indicating motor control fault

Ranked causes

  1. 1. Motor control faulty (rare)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Error code E-4 displayed caution

Display shows error E-4 indicating motor control monitoring circuit failure

Ranked causes

  1. 1. Motor control monitoring circuit faulty (rare)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Error code L 1 displayed

Display shows L 1 error code during operation.

Ranked causes

  1. 1. Quick activation button flow set too low or too high (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Set value flashes and pump deactivates

Display shows flashing set value; pump stops operating

Ranked causes

  1. 1. Activation time exceeded 20 seconds (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Error codes

CodeMeaningTriggerSeverity
E-1Motor control faultyMotor control failureerror
E-2Motor current exceeds permissible limitCurrent draw above safe thresholderror
E-3No measurable current flowNo motor current detectederror
E-4Motor control monitoring circuit faultyMonitoring circuit failureerror
E 5CRC Check faultyMemory integrity check failurewarning
L 1Quick activation button programmed with incorrect flowButton activation attemptwarning

Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI