Canon CXDI V640: troubleshooting and error codes

The ServiceForge knowledge base holds 11 documented symptoms for the Canon CXDI V640, with 14 ranked causes, 8 diagnostic checks with test points and expected values, and 52 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI

Symptoms

TLS handshake or certificate authentication failure caution

TLS connection or certificate validation error preventing secure communication with PACS during Node Authentication.

Ranked causes

  1. 1. TLS certificate invalid, expired, revoked, or cipher suite mismatch (occasional)
  2. 2. TLS certificate folder missing or improperly configured (rare)
  3. 3. TLS library not installed or version mismatch (rare)
First check

Verify certificate validity and format

Test point
TLS certificate file
Expected
Valid certificate with non-expired validity period

3 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI

Shared folders on CXDI PC cannot be opened from other PCs

Network shared folders configured on the CXDI system are not accessible from client computers

Ranked causes

  1. 1. Shared Folder Setting is inactive (common)
  2. 2. Administrator has not logged in as supervisor user (occasional)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

CXDI PC is invisible from other PCs on network

CXDI system cannot be accessed or seen by other computers on the network

Ranked causes

  1. 1. CXDI PC has not started (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Error occurred saving reject information to file

Warning 539 appears during image transfer; system asks if user wants to retry the save operation with patient identification displayed

Ranked causes

  1. 1. Unspecified error during reject info file save operation (occasional)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Reject information cannot be saved to CSV file

Error message displayed when attempting to save rejection information; directory is read-only or file format contains incorrect strings

Ranked causes

  1. 1. Selected directory for reject list is read-only (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Reject information file format error

Error or warning message indicates the reject list file format contains incorrect strings preventing save operation

Ranked causes

  1. 1. File format for reject list includes incorrect strings (occasional)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Reject list directory does not exist or has incorrect attribution

Warning message indicates the selected directory path is invalid or has incorrect access attributes

Ranked causes

  1. 1. Selected directory does not exist or attribution is incorrect (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Storage Commitment Request reception failed - Association Connection error

Association Connection Request fails during Storage Commitment Request reception; xxxxx.nod error file generated.

Ranked causes

  1. 1. Association Connection Request error (TLS or network) (occasional)
First check

Verify TLS certificate validity and installation

Test point
Certificate folder and files
Expected
srv-certs folder present with valid, non-expired certificate files

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Storage Commitment Request reception failed - Node Authentication error

Node Authentication error during Storage Commitment Request reception; xxxxx.nod file generated in logs/err/ directory.

Ranked causes

  1. 1. Node Authentication failed during Association Connection (occasional)
First check

Verify Node Authentication configuration on CXDI and PACS

Test point
Node Authentication ON/OFF settings
Expected
Both systems must have matching Node Authentication settings (both ON or both OFF) per table 7.4.6

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Storage Commitment Request result failed

Error returned in Storage Commitment Request result from PACS; QID_XXX.err and QID_XXX.txt files generated.

Ranked causes

  1. 1. PACS rejected Storage Commitment Request (processing, resource, or SOP class issue) (occasional)
First check

Verify SOP Instance is supported by PACS

Test point
Storage Commitment Request SOP Class
Expected
SOP Class matches one supported by SCP (PACS)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Storage Commitment Request transmission failed

Warning dialog displayed when Storage Commitment Request transmission from CXDI to PACS encounters an error during exposure output or study completion.

Ranked causes

  1. 1. Communication error or network connectivity issue (common)
First check

Review error code displayed in warning dialog

Test point
Error dialog message
Expected
Error code -540, -541, -542, or -543

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Error codes

CodeMeaningTriggerSeverity
0x0110Processing failureGeneral processing error in Storage Commitment Request operationerror
0x0112No such object instanceReferenced SOP Instance not found on PACSerror
0x0119Class/Instance conflictSOP Class of Referenced Instance does not match registered SOP Class at PACSerror
0x0122Referenced SOP Class not supportedStorage Commitment requested for SOP Class not supported by PACSerror
0x0131Duplicate transaction UIDStorage Commitment Request with duplicate Transaction UID already pendingwarning
0x0213Resource limitationPACS does not have sufficient storage resources for Storage Commitmentwarning
-1TLS Doesn't ConnectAttempted TLS connection to PACS during Node Authenticationerror
-10000TLS SSLLIB_F IS NOT INSTALLEDTLS security library SSLLIB_F is not installed on systemcritical
-137TLS Cert Unknown FormatCertificate file format is not recognized during loadingerror
-139TLS Cert Invalid SignCertificate digital signature validation fails during TLS handshakeerror
-2021TLS (A) Decryption failedDecryption error on TLS Alert Protocol messageerror
-2022TLS (A) Record OverflowTLS record exceeds maximum allowed sizeerror
-2040TLS (A) Handshake FailureTLS handshake negotiation failederror
-2042TLS (A) Bad CertificateCertificate validation fails during TLS handshakeerror
-2043TLS (A) Unsupported CertificateCertificate version or type is not supported by TLS implementationerror
-2044TLS (A) Certificate RevokedCertificate has been revoked by issuing Certificate Authorityerror
-2046TLS (A) Certificate UnknownCertificate cannot be verified or matched during validationerror
-2047TLS (A) Illegal ParameterTLS message contains illegal parameter valueerror
-2048TLS (A) Unknown CACertificate Authority in TLS message is not recognizederror
-2049TLS (A) Access DeniedTLS connection access is denied by PACSerror
-2050TLS (A) Decode ErrorTLS message decoding failserror
-2051TLS (A) Decrypt ErrorTLS data decryption failserror
-2060TLS (A) Export RestrictionEncryption export or usage restrictions applywarning
-2070TLS (A) Protocol VersionTLS protocol version mismatch between CXDI and PACSerror
-2071TLS (A) Insufficient SecurityTLS security level is insufficienterror
-256TLS Cert Expiration of ValidityCertificate validity period has expirederror
-3000TLS Socket ErrorTLS socket creation or operation failserror
-3001TLS Socket Option ErrorTLS socket option configuration failserror
-3002TLS Bind ErrorTLS socket bind to local address/port failserror
-3003TLS Listen ErrorTLS socket listen operation failserror
-3004TLS Cert Folder NameTLS certificate folder name is invalid or not accessibleerror
-3005TLS Upper VersionTLS upper version parameter is invalid or unsupportederror
-3006TLS Lower VersionTLS lower version parameter is invalid or unsupportederror
-3007TLS PrivateKey file RSATLS private key file designation error or key has been revokederror
-3008TLS Certificate file RSATLS certificate file designation error or certificate has been revokederror
-33TLS Client FIN ErrorTLS client FIN packet error during handshake or data transmissionerror
-34TLS Client BAD MACMessage Authentication Code generation or verification failureerror
-384TLS Cert Unknown CACertificate Authority in certificate chain cannot be verifiederror
-385TLS Cert Folder not foundCertificate storage folder (srv-certs) does not exist or is not accessibleerror
-50TLS Srv Hello No DataTLS server hello message received with no data payloaderror
-51TLS Srv Fin No DataTLS server FIN message received with no dataerror
-64TLS No Shared CipherCipher suites negotiation failure during TLS handshakeerror
-65TLS Need CertificateTLS handshake requires client certificate but none is configurederror
Error 535Reject Info Output ErrorCXDI startup when selected directory for reject list can only be readerror
Error 537Reject Info Output ErrorCXDI startup when file format for reject list includes incorrect stringserror
Error message: no folder name specifiedCSV file output destination folder not configuredCharacter string entry when CSV output destination folder property is emptyerror
Error message: odd number of % symbolsCSV output format string contains invalid placeholder syntaxCharacter entry in CSV file output format property or CXDI start when reject reason function activeerror
Error message: specified folder does not existCSV output destination folder path is invalid or missingCXDI start when reject reason function is activeerror
Internal storage Limit Warning (-547)Available internal storage space has dropped below thresholdAvailable internal storage space drops below Store Recovery MB thresholdwarning
Warning 535Reject Info Output ErrorDuring image transfer when selected directory does not exist or has incorrect attributionwarning
Warning 537Reject Info Output ErrorDuring image transfer when file format for reject list includes incorrect stringswarning
Warning 539Reject Info Output ErrorDuring image transfer when error occurs saving reject info to filewarning

Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI

Community

0 fixes logged by technicians through their AI, with outcomes, for this model.

ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.