Test equipment evoked otoacoustic emissions systems

Bio-Logic Systems AuDX: troubleshooting and error codes

The ServiceForge knowledge base holds 4 documented symptoms for the Bio-Logic Systems AuDX, with 6 ranked causes, 0 diagnostic checks with test points and expected values, and 7 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI

Symptoms

Initialization software not found or corrupted

System displays error message on LCD; device fails to boot

Ranked causes

  1. 1. Initialization software not installed or corrupted (occasional)
  2. 2. Persistent software corruption after reset (rare)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Unit powers off unexpectedly

Battery discharge message flashes for 10 seconds then unit shuts down

Ranked causes

  1. 1. Battery completely depleted (common)
  2. 2. Insufficient charge for extended operation (common)

2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI

Button stuck or held too long

System displays 'PLEASE RELEASE BUTTON!' message on LCD

Ranked causes

  1. 1. Button held down longer than 0.3 seconds (common)

1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI

Database empty or missing data

System displays 'EMPTY DATABASE' error message on LCD

Ranked causes

  1. 1. Database not initialized or cleared (unknown)

Error codes

CodeMeaningTriggerSeverity
EMPTY DATABASENo tests stored in memory; database is emptyAttempt to view data when database empty; occurs after new software version uploadedinfo
LOADING #.##.## PLEASE WAIT...Software loading in progress during power-on sequenceDX (SELECT) button pressed during initializationinfo
LOW BATTERY!!! CONNECT CHARGERBattery charge completely depletedBattery charge reaches zerowarning
MEMORY ERROR RELOAD SOFTWAREInitialization software not found or corruptedSoftware missing or corrupted during startuperror
NO LOADER RELOAD SOFTWAREInitialization software not found or corruptedSoftware missing or corrupted during startuperror
PLEASE RELEASE BUTTON!Button on AuDX label held depressed longer than 0.3 secondsButton depressed for more than 0.3 secondsinfo
TURN PRINTER ON TRY AGAINSerial label printer not connected or not powered onAttempt to print data on serial label printerwarning

Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI