Agilent 6033A: troubleshooting and error codes
The ServiceForge knowledge base holds 26 documented symptoms for the Agilent 6033A, with 45 ranked causes, 85 diagnostic checks with test points and expected values, and 16 error codes. Each symptom below shows its causes and the first check; the rest is one connection away. Connect ServiceForge to your AI
Symptoms
Signature mismatch at data or address pin
Measured signature at IC pin differs from reference table value, indicating signal integrity issue or component fault
Ranked causes
- 1. IC pin shorted to Vcc or ground (common)
- 2. Two pins shorted together (occasional)
- 3. PCB trace or solder joint discontinuity (occasional)
- 4. Faulty component loading down node (occasional)
Compare measured signature to Table 3-4 reference value
- Test point
- Target address or data line pin on processor IC
- Expected
- Exact match to Table 3-4 entry for firmware revision
3 more checks with pass and fail actions, 4 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Data and address lines not toggling
Address lines A0-A15 or data lines D0-D7 not toggling on secondary interface ICs U6, U8, U12, U14, U16, U17, U36
Ranked causes
- 1. Data or address line shorted high or low (common)
- 2. Socketed IC fault (occasional)
- 3. GPIB assembly fault (occasional)
Check address lines A0 to A15 for toggling
- Test point
- U6, U8, U12, U14, U16, U17, U36
- Expected
- Toggling
1 more check with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Front panel RPG and switch input malfunction
Rotary pulse generator (RPG) or front panel switches not responding correctly to user input
Ranked causes
- 1. U11 shift register defective (occasional)
- 2. U12 flip-flop defective (occasional)
- 3. U18 gate IC defective (occasional)
Measure signature at shift register U11 input
- Test point
- U11-1
- Expected
- 1ABC
4 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
No output from power supply high voltage
Unit produces no DC output voltage; FETs may fail from excessive power dissipation if off-pulses or power-limit comparator fails
Ranked causes
- 1. PWM-OFF and PWM-ON both low; control circuit failure (common)
- 2. PWM-ON high, PWM-OFF low or high; A4Q3 and A4Q4 PFETs failed (common)
- 3. Power-limit comparator failure; both PWM pulses absent (occasional)
Measure bias voltages and PWM signals
- Test point
- A2 control board test fingers A2J3
- Expected
- PWM-OFF and PWM-ON present as 1.7µs TTL pulses at 20KHz
2 more checks with pass and fail actions, 3 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Clock signal frequencies incorrect
Clock signals at C7+, C8+ (12MHz from Y2), J5-8 (6MHz from U14), or U35-12 not at specified frequency
Ranked causes
- 1. Crystal oscillator Y2 fault (unknown)
- 2. Clock divider circuit fault (unknown)
Measure frequency at C7+ and C8+ clock nodes
- Test point
- C7+, C8+
- Expected
- 12MHz
- Tools
- Frequency counter, oscilloscope
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Current limit circuit not functioning caution
Unit does not limit output current to specified maximum; CC circuit defective
Ranked causes
- 1. CC (constant current) circuit defective on A2 board (common)
- 2. Maximum current below specification; CC clamp circuit failure (occasional)
Set output to rated current limit; measure actual output current
- Test point
- Unit output terminals with load
- Expected
- 30Adc (6033A) or 10Adc (6038A) maximum
- Tools
- DMM or clamp ammeter
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Data or address line shorted high or low
Unit will not enter SA mode despite correct J5 jumper positioning
Ranked causes
- 1. Data line shorted high or low (occasional)
- 2. Address line shorted high or low (occasional)
Attempt to place unit in primary SA mode with J5 jumper at pins 3 and 4
- Test point
- J5 jumper position and front panel display
- Expected
- Display shows 'SA SA' within normal startup time
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Front panel address latch or decoder malfunction
Address decoding not functioning correctly, affecting LED display multiplexing or front panel control
Ranked causes
- 1. U15 address latch defective (occasional)
- 2. Address decoder IC defective (U13, U14, or U16) (occasional)
Measure signature at address latch U15 input pins during power cycle
- Test point
- U15-9, U17-3,6
- Expected
- Cycle power to unit - Lo to Hi after approx. 160 ms
2 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Maximum voltage less than specified caution
Output voltage does not reach full rated voltage; CV circuit or input rectifier diodes defective
Ranked causes
- 1. CV circuit defective or low AC mains voltage (common)
- 2. Input rectifier diodes A1CR1–CR4 open or shorted (occasional)
Measure output voltage at full setting
- Test point
- Unit output terminals
- Expected
- 20Vdc (6033A) or 60Vdc (6038A)
1 more check with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Readback DAC waveform incorrect high voltage
Readback DAC output waveform at U67-6 is not correct when varying output voltage from zero to full scale during selftest
Ranked causes
- 1. Readback DAC circuit fault (unknown)
- 2. Readback multiplexer fault (unknown)
Toggle on/off switch repeatedly to perform selftest
- Test point
- On/off switch
- Expected
- Selftest routine executed
4 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Troubleshooting -15V bias supply caution
Verification of -15V regulated output from voltage regulator A2U4
Ranked causes
- 1. Regulator A2U4 failure or feedback resistor A2R32 open (rare)
- 2. Zener diode A2VR2 shorted or interconnecting resistor open (occasional)
Measure negative input voltage at A2U4 IN
- Test point
- A2U4 (IN), A2C16 (-)
- Expected
- ≈ - 24Vdc
- Tools
- DMM
4 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Troubleshooting +15V bias supply caution
Verification of +15V output from voltage regulator A2U12 and zener feedback network
Ranked causes
- 1. Regulator A2U12 failure or adjustment resistor R29 open (rare)
- 2. Zener diode A2VR1 shorted or current-limiting resistor open (occasional)
Measure input voltage at A2U12 IN
- Test point
- A2U12 (IN), A2C17 (+)
- Expected
- ≈ 24Vdc
- Tools
- DMM
4 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Troubleshooting +5V bias supply caution
Verification of +5V regulated output from A2U6 PWM controller and A2U5 regulator
Ranked causes
- 1. PWM controller failure or compensation network open (rare)
- 2. Regulator A2U5 or output filter capacitor failed (occasional)
Measure input voltage at A2J3-22
- Test point
- A2J3-22
- Expected
- ≈ 20Vdc
- Tools
- DMM
4 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Troubleshooting Down Programmer circuit high voltage
Verification of down-programmer output loading function and 8.9V bias supply
Ranked causes
- 1. Comparator A4U3B threshold shifted or feedback divider open (rare)
- 2. Transistor A4Q6 shorted or output resistors open (occasional)
Measure 8.9V bias output at A4U4 OUT
- Test point
- A4U4 (OUT)
- Expected
- 8.9Vdc, ±0.2V
- Tools
- DMM
2 more checks with pass and fail actions are in ServiceForge. Connect ServiceForge to your AI
+5V and PCLR circuit voltages incorrect high voltage
Voltages at PCLR and +5V circuit nodes U1-2, U1-3, U1-4, U1-6, or U1-8 not within specification
Ranked causes
- 1. +5V power supply fault (unknown)
Measure voltage at U1-8
- Test point
- U1-8
- Expected
- ≈3.5Vdc, ±0.1V
- Tools
- DMM
4 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Blank front panel Option 001 troubleshooting
Difficulty isolating defects in Option 001 units without front panel indicators; flowchart provided for problem isolation
Ranked causes
- 1. Defect in specific section of power supply (unknown)
2 corrective actions and part numbers are in ServiceForge. Connect ServiceForge to your AI
Current DAC output incorrect high voltage
CC DAC not producing expected current at output nodes U68-6 and U65-6 when front panel current control is varied from zero to full scale
Ranked causes
- 1. CC DAC circuit fault (unknown)
Turn off unit and connect short across output terminals
- Test point
- Output
- Expected
- Short circuit connected
4 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Excessive output noise (>1 kHz) caution
Output contains high-frequency noise above 1 kHz, indicating transformer, filter, or snubber issues
Ranked causes
- 1. Transformer T1 or output filter defective; snubber network failure (common)
Measure output noise spectrum
- Test point
- Unit output terminals
- Expected
- Noise <1 kHz peak-to-peak
- Tools
- Oscilloscope
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Front panel LED display segment or indicator malfunction
One or more 7-segment LED displays or individual LED indicators not illuminating or showing incorrect segments
Ranked causes
- 1. Faulty LED driver IC (U1 to U10) (common)
Place unit in primary SA mode and measure signature at LED driver input pin 1
- Test point
- U1 to U10-1
- Expected
- 6H15
3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Front panel operation unavailable
Option 001 unit has no front-panel controls and indicators except LINE switch, OVP ADJUST control, and pilot light
Ranked causes
- 1. Unit shipped with Option 001 blank front panel (common)
Verify available controls
- Test point
- Front panel
- Expected
- LINE switch, OVP ADJUST control, and ac input pilot light only
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Incorrect signature analyzer reading in primary mode
Front panel display does not show 'SA SA' or LEDs do not all illuminate when unit placed in primary SA mode
Ranked causes
- 1. U14 defective (common)
Verify unit placed in primary SA mode by moving J5 jumper
- Test point
- J5 jumper
- Expected
- Pins 3 and 4 connected (SA mode position)
1 more check with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Output current oscillation high voltage
Output current oscillates during power section operation
Ranked causes
- 1. Differentiator circuit fault (common)
Observe output current oscillation
- Test point
- Output
- Expected
- No oscillations
1 corrective action and part numbers are in ServiceForge. Connect ServiceForge to your AI
Troubleshooting CC (Constant Current) circuit caution
Verification of current monitor amp, CC error amp and differentiator stabilization
Ranked causes
- 1. CC Error Amp A2U2B gain or offset fault (rare)
Measure current monitor output IM at A2U1 with 0.5A load
- Test point
- IM
- Expected
- 0.50Vdc (1/6 of 0.5A = 0.083V per amp, but expect 0.50V), ±0.05V
- Tools
- DMM
4 more checks with pass and fail actions are in ServiceForge. Connect ServiceForge to your AI
Troubleshooting CV (Constant Voltage) circuit caution
Verification of voltage monitor amp, CV error amp and inner-loop stabilization
Ranked causes
- 1. CV Error Amp A2U8 offset shift or oscillation in inner loop (occasional)
Measure voltage monitor output VM at A2U10C-8
- Test point
- A2U10C-8
- Expected
- 3.75Vdc, ±0.1V
- Tools
- DMM
3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Troubleshooting DC-to-DC Converter high voltage
Verification of PFET drivers, on/off pulse generators and power mesh switching on A4 board
Ranked causes
- 1. PFET gate drive signal weak or absent (occasional)
Measure PWM-ON input waveform at A2J3-26
- Test point
- A2J3-26 (PWM-ON)
- Expected
- waveform #1
- Tools
- Oscilloscope
5 more checks with pass and fail actions, 2 corrective actions, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Voltage DAC output incorrect high voltage
CV DAC not producing expected voltage at output nodes U69-6 and U64-6 when front panel voltage control is varied from zero to full scale
Ranked causes
- 1. CV DAC circuit fault (unknown)
Measure CV DAC output at U69-6 with voltage set to zero
- Test point
- U69-6
- Expected
- 0V
- Tools
- DMM
3 more checks with pass and fail actions, 1 corrective action, and part numbers are in ServiceForge. Connect ServiceForge to your AI
Error codes
| Code | Meaning | Trigger | Severity |
|---|---|---|---|
ERROR 10 | Internal ROM Test failure | error | |
ERROR 12 | ADC Zero Too High | error | |
ERROR 13 | Voltage DAC Full Scale Low | error | |
ERROR 14 | Voltage DAC Full Scale High | error | |
ERROR 15 | Voltage DAC Zero Low | error | |
ERROR 16 | Voltage DAC Zero High | error | |
ERROR 17 | Current DAC Full Scale Low | error | |
ERROR 18 | Current DAC Full Scale High | error | |
ERROR 19 | Current DAC Zero Low | error | |
ERROR 20 | Current DAC Zero High | error | |
ERROR 4 | External RAM Test failure | error | |
ERROR 5 | Internal RAM Test failure | error | |
ERROR 6 | External ROM Test failure | error | |
ERROR 7 | GPIB Test failure | error | |
ERROR 8 | GPIB address set to 31 | warning | |
STARTUP_FAILURE | Power supply fails turn-on self-test | Power supply does not pass self-test or indicates malfunction on startup | critical |
Likely causes and actions for each code are in ServiceForge. Connect ServiceForge to your AI
Community
0 fixes logged by technicians through their AI, with outcomes, for this model.
ServiceForge knowledge base record. Field-unverified unless technicians confirmed it. A teaching summary of the record, not a service manual. Export 2026-10-14.