FR FieldReady Academy
CompTIA A+ Core 2 220-1202

CompTIA A+ Core 2 220-1202 Flashcards: 405 cards

405 free CompTIA A+ Core 2 flashcards from the course's cheat sheet and glossary. Tap a card to flip it. Mark the ones you know and they drop out of the deck; the rest keep coming back.

Acronyms 194

5G
Fifth-generation cellular. The current mobile network generation with higher speed and lower latency than LTE.
802.1X
IEEE 802.1X. Port-based network access control: a device must authenticate before the switch port or Wi-Fi passes traffic.
ABC
Class A, B, and C fire extinguisher. A multipurpose extinguisher for ordinary combustibles, flammable liquids, and electrical fires.
AC
Alternating current. Mains power, which reverses direction 60 times a second in North America.
ACL
Access control list. An ordered list of permit and deny rules on a router, firewall, or file system.
AD
Active Directory. Microsoft's directory service: the domain's database of users, computers, and groups.
AES
Advanced Encryption Standard. The standard symmetric cipher, with 128, 192, or 256-bit keys.
AES-CCMP
AES in CCMP mode. The AES-based encryption WPA2 uses for Wi-Fi.
AI
Artificial intelligence. Software that learns patterns and generates text, images, or decisions.
AP
Access point. The radio that bridges Wi-Fi clients onto the wired network.
APFS
Apple File System. The modern macOS and iOS file system with snapshots and encryption.
APN
Access point name. The gateway setting a phone uses to reach a carrier's data network.
ARP
Address Resolution Protocol. Finds the MAC address that goes with a known IPv4 address on the local segment.
AUP
Acceptable use policy. The rules for how staff may use company systems and data.
BEC
Business email compromise. Fraud by email impersonating an executive or vendor to redirect payments.
BIOS
Basic Input/Output System. The original PC firmware: 16-bit, text setup, MBR disks up to 2 TB.
BSOD
Blue screen of death. The Windows stop error screen from a driver or hardware fault.
BYOD
Bring your own device. Staff use personal phones and laptops for work.
CAD
Computer-aided design. Engineering and drafting software that needs a workstation-class GPU and RAM.
CCMP
Counter Mode with Cipher Block Chaining Message Authentication Code Protocol. The AES-based encryption WPA2 uses.
CEO
Chief executive officer. The top executive; the person impersonated in whaling and business email compromise.
CFO
Chief financial officer. The executive in charge of money; a common target and impersonation in payment fraud.
CMDB
Configuration management database. The inventory of IT assets and how they relate, used in change and incident management.
CMOS
Complementary metal-oxide semiconductor. The small battery-backed memory that keeps firmware settings and the clock.
CO2
Carbon dioxide. The gas in CO2 fire extinguishers, which are safe on energized electrical equipment.
CPU
Central processing unit. The processor that executes instructions.
CRT
Cathode ray tube. The old glass-tube monitor; holds dangerous voltage even when unplugged.
DC
Domain controller. The server that runs Active Directory and authenticates domain logons.
DDoS
Distributed denial of service. Many sources, usually a botnet, flood a target at once.
DHCP
Dynamic Host Configuration Protocol. Hands out IP addresses, masks, gateways, and DNS servers automatically (UDP 67 and 68).
DISM
Deployment Image Servicing and Management. The Windows tool that repairs the component store and services images.
DLP
Data loss prevention. Tools that detect and block sensitive data leaving by email, web, USB, or cloud.
DMA
Direct memory access. Devices move data to and from memory without going through the CPU.
DMZ
Demilitarized zone. A screened subnet between the internet and the internal network for public-facing servers.
DNS
Domain Name System. Translates names such as www.example.com into IP addresses (UDP 53, TCP 53 for zone transfers).
DoH
DNS over HTTPS. DNS queries carried inside HTTPS on TCP 443 so they cannot be read or altered in transit.
DoS
Denial of service. One source floods or crashes a target so it cannot serve users.
DRM
Digital rights management. Technology that restricts copying and use of licensed content and software.
DSS
Data Security Standard. The PCI DSS rules for protecting payment card data.
DVD
Digital versatile disc. Optical media holding 4.7 GB, or 8.5 GB dual layer.
DWORD
Double word. A 32-bit registry value type.
EAP
Extensible Authentication Protocol. The framework that carries authentication methods inside 802.1X.
EDR
Endpoint detection and response. Endpoint agents that record activity, detect attacks, and let responders isolate and clean the machine.
EFS
Encrypting File System. Per-file and per-folder encryption built into NTFS, tied to the user's account.
EOL
End of life. The vendor stops selling the product.
ESD
Electrostatic discharge. Static electricity that can destroy chips; prevented with a wrist strap, mat, and antistatic bags.
eSIM
Embedded SIM. A SIM built into the phone and provisioned by software.
EULA
End-user license agreement. The license terms a user accepts to install software.
exFAT
Extended File Allocation Table. A FAT variant for flash media with no 4 GB file limit.
ext4
Fourth extended file system. The common Linux file system.
FAT
File Allocation Table. The family of simple file systems (FAT16, FAT32, exFAT).
FAT32
File Allocation Table 32-bit. The simple, universal file system for USB drives; 4 GB file limit, no permissions.
FRT
Facial recognition technology. Biometric authentication by face.
FTP
File Transfer Protocol. Plaintext file transfer on TCP 21 (control) and 20 (data); replace with SFTP or FTPS.
GB
Gigabyte. About a billion bytes; the unit for RAM, storage, and data caps.
GFS
Grandfather-father-son. A backup rotation with daily, weekly, and monthly sets kept for increasing periods.
GHz
Gigahertz. Billions of cycles per second; CPU clock speed and Wi-Fi band frequency.
GPO
Group Policy Object. A set of Windows settings applied to users and computers, locally or through Active Directory.
GPT
GUID Partition Table. The modern disk partition scheme: any disk size, up to 128 partitions, required for UEFI boot.
GPU
Graphics processing unit. The processor that renders images; on a card or built into the CPU.
GRUB
Grand Unified Bootloader. The Linux boot loader that presents the kernel menu.
GUI
Graphical user interface. Windows, icons, and a mouse, as opposed to a command line.
GUID
Globally unique identifier. A 128-bit random identifier used for partitions, objects, and records.
HDD
Hard disk drive. Spinning magnetic storage: cheap per terabyte, slower, and fragile.
HFS+
Hierarchical File System Plus. The older macOS file system, replaced by APFS.
HIPAA
Health Insurance Portability and Accountability Act. The US law protecting health information and setting privacy and security rules.
HKCU
HKEY_CURRENT_USER. The registry hive holding the logged-in user's settings.
HKLM
HKEY_LOCAL_MACHINE. The registry hive holding machine-wide settings.
HR
Human resources. The department that hires and separates staff; its system should drive account provisioning and removal.
HTTP
Hypertext Transfer Protocol. Web traffic in the clear on TCP 80.
HTTPS
Hypertext Transfer Protocol Secure. HTTP inside TLS on TCP 443.
IAM
Identity and access management. The systems and processes for creating accounts, authenticating users, and granting permissions.
ID
Identifier or identification. A name or number that uniquely labels a user, device, session, or record.
iOS
iPhone operating system. Apple's mobile operating system for iPhone.
IP
Internet Protocol. The Layer 3 protocol that addresses and routes packets between networks.
iPadOS
iPad operating system. Apple's tablet operating system, a variant of iOS.
IPsec
Internet Protocol Security. The suite that encrypts and authenticates IP packets for VPNs.
IPv6
Internet Protocol version 6. 128-bit addresses in eight hex groups; no broadcast, built-in autoconfiguration.
IRQ
Interrupt request. The signal a device uses to get the CPU's attention.
IRQL
Interrupt request level. The priority level of Windows kernel code; a common stop code names it.
ISO
International Organization for Standardization; also an ISO disc image. The standards body, and the .iso file format that holds a complete disc image.
ISP
Internet service provider. The company that connects you to the internet.
IT
Information technology. Computers, networks, and the people who run them.
JIT
Just-in-time access. Privileges are granted only when needed and removed afterward.
KB
Kilobyte. About a thousand bytes.
KDC
Key Distribution Center. The Kerberos service on a domain controller that issues tickets.
KVM
Kernel-based Virtual Machine. The Linux kernel's built-in type 1 hypervisor, managed with QEMU and libvirt.
L2TP
Layer 2 Tunneling Protocol. A VPN tunneling protocol that needs IPsec for encryption (L2TP/IPsec).
LAN
Local area network. One site's network: a building, floor, or campus that one organization owns and runs.
LDAP
Lightweight Directory Access Protocol. Queries a directory such as Active Directory for users and groups; TCP 389, secure 636.
LTO
Linear Tape-Open. The standard tape format for backups and archives.
MAC
Media access control (address). The 48-bit hardware address burned into a network interface, used at Layer 2.
macOS
Mac operating system. Apple's desktop operating system.
MBR
Master boot record. The legacy partition scheme: disks up to 2 TB, four primary partitions, BIOS boot.
MBR2GPT
MBR to GPT conversion tool. The Windows command that converts a disk from MBR to GPT without data loss.
MDM
Mobile device management. Software that enrolls phones and tablets and enforces policy: passcodes, encryption, apps, remote wipe.
MDR
Managed detection and response. An outsourced team that monitors your EDR or XDR and responds around the clock.
MDT
Microsoft Deployment Toolkit. Free Microsoft tooling for building and deploying Windows images.
MFA
Multi-factor authentication. Two or more different kinds of proof: something you know, have, are, or where you are.
MMC
Microsoft Management Console. The framework that hosts administrative snap-ins such as Device Manager and Event Viewer.
MNDA
Mutual non-disclosure agreement. An NDA that binds both parties equally.
MSDS
Material safety data sheet. The older name for the safety data sheet.
NAS
Network-attached storage. A file server appliance that shares folders over the regular network using SMB or NFS.
NAT
Network address translation. Rewrites private inside addresses to a public address at the router so many hosts can share it.
NDA
Non-disclosure agreement. A contract that keeps shared information confidential.
NFC
Near-field communication. Very short range radio (about 4 cm) at 13.56 MHz for tap-to-pay and badge readers.
NFO
System Information file. The .nfo file saved by msinfo32 with a full hardware and software inventory.
NIC
Network interface card. The adapter that connects a computer to the network, wired or wireless.
NLA
Network Level Authentication. Remote Desktop authenticates the user before showing a logon screen.
NTFS
New Technology File System. The standard Windows file system: permissions, encryption, compression, large files, journaling.
NTP
Network Time Protocol. Synchronizes clocks across the network (UDP 123); wrong time breaks Kerberos, certificates, and logs.
NVMe
Non-Volatile Memory Express. The fast SSD interface that talks to PCIe lanes directly, usually in an M.2 slot.
OS
Operating system. The software that manages hardware and runs applications: Windows, macOS, Linux, iOS, Android.
OSHA
Occupational Safety and Health Administration. The US agency that sets workplace safety rules.
OTP
One-time password. A code that is valid for a single login.
OU
Organizational unit. A container in Active Directory used to group users and computers so policies and delegation can target them.
PAC
Proxy auto-configuration file. A script that tells the browser which proxy to use for each URL.
PAM
Privileged access management. Controls and records the use of administrator accounts.
PC
Personal computer. A desktop or laptop for one user.
PCI
Payment Card Industry. The card brands' rules (PCI DSS) for anyone who stores, processes, or transmits payment card data.
PID
Process identifier. The number the operating system gives each running process.
PII
Personally identifiable information. Data that identifies a person: name, address, Social Security number, date of birth.
PIN
Personal identification number. A short numeric secret, a something-you-know factor.
POST
Power-on self-test. The firmware's hardware check at power-up; failures show as beep codes or a POST card reading.
PSK
Pre-shared key. One shared passphrase for everyone on a Wi-Fi network (Personal mode).
PSU
Power supply unit. Converts wall AC to the DC voltages a computer needs: 12 V, 5 V, 3.3 V.
PUP
Potentially unwanted program. Software that rides along with a download: toolbars, adware, bundled utilities.
PXE
Preboot Execution Environment. Booting a computer from the network to install or image an operating system.
QEMU
Quick Emulator. The open-source machine emulator often paired with KVM.
QR
Quick response code. The square barcode a phone camera reads.
RADIUS
Remote Authentication Dial-In User Service. The AAA server behind Wi-Fi Enterprise, VPNs, and 802.1X; UDP 1812 and 1813.
RAID
Redundant array of independent disks. Combining disks for speed, capacity, or fault tolerance: 0 stripe, 1 mirror, 5 stripe with parity, 6 double parity, 10 mirrored stripes.
RAM
Random-access memory. The working memory that holds running programs and data; lost at power off.
RDP
Remote Desktop Protocol. Microsoft's remote graphical desktop on TCP 3389.
RFID
Radio-frequency identification. Tags read by radio for badges, inventory, and asset tracking.
RHEL
Red Hat Enterprise Linux. Red Hat's commercially supported Linux distribution.
RMM
Remote monitoring and management. Tools that managed service providers use to monitor, patch, and remotely control many computers.
S.M.A.R.T
Self-Monitoring, Analysis, and Reporting Technology. Drive self-diagnostics that warn of impending failure.
SAE
Simultaneous authentication of equals. The WPA3 Personal handshake that resists offline password guessing.
SAML
Security Assertion Markup Language. An XML standard for passing authentication between an identity provider and a web application (enterprise SSO).
SCP
Secure Copy Protocol. Simple file copying over SSH, TCP 22.
SD
Secure Digital card. The flash memory card used in cameras and devices; miniSD and microSD are the smaller sizes.
SDS
Safety data sheet. The document describing a chemical's hazards, handling, and first aid; formerly MSDS.
SFTP
SSH File Transfer Protocol. File transfer inside an SSH session, TCP 22.
SHA-256
Secure Hash Algorithm 256-bit. The standard hash today: a 256-bit fingerprint of any input.
SIM
Subscriber identity module. The card or embedded chip that identifies a phone to the cellular network.
SLA
Service level agreement. The contract stating measurable service commitments, such as 99.9% uptime.
SMB
Server Message Block. Windows file and printer sharing on TCP 445.
SMS
Short Message Service. Text messages; used for one-time codes and also a phishing channel (smishing).
SOHO
Small office, home office. A small network with a consumer-grade router doing NAT, DHCP, Wi-Fi, and firewall in one box.
SOP
Standard operating procedure. A documented, step-by-step way of doing a routine task.
SPICE
Simple Protocol for Independent Computing Environments. An open remote display protocol for virtual machines.
SQL
Structured Query Language. The language used to query databases; also the name of the servers on TCP 1433 (Microsoft) and 3306 (MySQL).
SSD
Solid-state drive. Flash storage with no moving parts: fast, silent, and shock resistant.
SSH
Secure Shell. Encrypted remote command-line access and file transfer on TCP 22; replaces Telnet and FTP.
SSID
Service set identifier. The Wi-Fi network name that access points broadcast and clients join.
SSO
Single sign-on. Log in once and reach many systems without signing in again.
SSTP
Secure Socket Tunneling Protocol. Microsoft's VPN protocol that carries PPP inside TLS on port 443.
TACACS+
Terminal Access Controller Access-Control System Plus. Cisco's AAA protocol for device administration on TCP 49; encrypts the whole payload and separates authentication from authorization.
TB
Terabyte. About a trillion bytes; the unit for large drives.
TCP
Transmission Control Protocol. Reliable, ordered, connection-based transport: three-way handshake, acknowledgments, retransmission.
TGT
Ticket-granting ticket. The Kerberos ticket a user receives at logon, used to request tickets for services.
TKIP
Temporal Key Integrity Protocol. WPA's per-packet keying scheme; deprecated.
TLS
Transport Layer Security. The encryption layer under HTTPS and most secure protocols; use 1.2 or 1.3.
TOTP
Time-based one-time password. A six-digit code from an authenticator app that changes every 30 seconds.
TPM
Trusted Platform Module. A security chip on the motherboard that stores keys and measurements; required for BitLocker and Windows 11.
TRIM
TRIM command. Tells an SSD which blocks are no longer in use so it can erase them ahead of time.
UAC
User Account Control. The Windows prompt that asks for consent or an administrator password before a privileged change.
UDP
User Datagram Protocol. Connectionless, fast transport with no delivery guarantee; used for voice, video, DNS, DHCP.
UEFI
Unified Extensible Firmware Interface. Modern firmware that replaces BIOS: GPT disks, Secure Boot, mouse-driven setup.
UID
User identifier. The number Linux uses to identify each user account.
UNC
Universal Naming Convention. The \\server\share path format for network resources.
UPS
Uninterruptible power supply. A battery unit that keeps equipment running through a power cut and conditions the power.
URL
Uniform resource locator. A web address such as https://www.example.com/page.
USB
Universal Serial Bus. The standard port for peripherals, storage, and charging.
VLAN
Virtual local area network. A logical LAN on a switch: ports in different VLANs are separate broadcast domains.
VM
Virtual machine. A complete computer running as software on a hypervisor.
VNC
Virtual Network Computing. A cross-platform remote desktop protocol.
VPN
Virtual private network. An encrypted tunnel across an untrusted network such as the internet.
VRAM
Video RAM. The memory on a graphics card that holds frames and textures.
WAN
Wide area network. Connects LANs across cities or countries, usually over links leased from a provider.
WEP
Wired Equivalent Privacy. The original Wi-Fi encryption, broken in minutes; never use it.
Wi-Fi
Wireless fidelity. The trade name for IEEE 802.11 wireless networking.
WLAN
Wireless local area network. A LAN delivered over Wi-Fi instead of cables.
WMI
Windows Management Instrumentation. The Windows framework for querying and managing system information, used by scripts and monitoring tools.
WPA
Wi-Fi Protected Access. The interim fix for WEP that used TKIP; deprecated.
WPA2
Wi-Fi Protected Access 2. Wi-Fi security using AES with CCMP; still common and acceptable.
WPA3
Wi-Fi Protected Access 3. The current Wi-Fi security standard: SAE in Personal mode, stronger encryption, protected management frames.
WPAD
Web Proxy Auto-Discovery. Lets a browser find its proxy settings automatically through DHCP or DNS.
WS-Management
Web Services for Management. The standard protocol behind Windows Remote Management and PowerShell remoting.
WWAN
Wireless wide area network. Cellular data connectivity, such as a laptop's built-in LTE or 5G modem.
XDR
Extended detection and response. EDR extended across endpoints, network, cloud, and email into one correlated view.
XFS
XFS file system. A high-performance journaling file system used by Red Hat Enterprise Linux and others.
XSS
Cross-site scripting. An attacker's script runs in other users' browsers because a site echoes untrusted input.

The exam itself 7

Exam
CompTIA A+ Core 2, 220-1202 (A+ needs Core 1 220-1201 and Core 2)
Questions and time
Up to 90 questions in 90 minutes; multiple choice plus performance-based items
Passing
700 on a scale of 100 to 900 (Core 1 needs 675)
Operating Systems
28%
Security
28%
Software Troubleshooting
23%
Operational Procedures
21%

Operating systems, filesystems, and Windows editions 16

Windows
Workstation OS; Home, Pro, Pro for Workstations, Enterprise; NTFS; domain or workgroup; the only one with Group Policy and BitLocker
Linux
Open-source kernel with distributions (Ubuntu and Debian use apt, Fedora and RHEL use dnf); ext4 or XFS; case-sensitive; root account; systemd
macOS
Apple desktops and laptops only; APFS; App Store; Time Machine; FileVault; Keychain; Spotlight
Chrome OS
Google's browser-centered OS on Chromebooks; cloud storage, Android apps, managed from the Google Admin console
iOS and iPadOS
Apple phones and tablets; closed app store; no sideloading without enterprise profiles
Android
Google's open mobile OS; many vendors; sideloading possible; more fragmentation of updates
Vendor life cycle
End-of-life (EOL): no more security updates; update limitations: hardware or edition blocks a version; Windows 10 support ended October 2025
Compatibility
Applications and drivers are built per OS and per architecture; 32-bit apps run on 64-bit Windows, not the reverse; files move between OSes only on filesystems both can read (exFAT, FAT32)
Home (10 and 11)
Consumer; workgroup only, no domain join; no BitLocker, no Remote Desktop host, no Group Policy Editor (gpedit.msc); 128 GB RAM limit
Pro (10 and 11)
Domain join, BitLocker, Remote Desktop host, gpedit.msc, Hyper-V; 2 TB RAM
Pro for Workstations (10)
ReFS, persistent memory, up to four CPUs, 6 TB RAM; for high-end workstations
Enterprise (10 and 11)
Volume licensing; adds AppLocker, DirectAccess, advanced management; 6 TB RAM
N versions
European editions without Media Player and media features
Desktop and RDP
Windows 11 has the centered taskbar and new Settings; every edition can be an RDP client, only Pro and above can be an RDP host
Upgrade paths
In-place upgrade keeps files, apps, and settings (Windows 10 to 11 if the hardware qualifies; Home to Pro with a key); clean install wipes; 32-bit to 64-bit requires a clean install
Windows 11 hardware
TPM 2.0, UEFI with Secure Boot capable, 64-bit dual-core 1 GHz CPU, 4 GB RAM, 64 GB storage

Installation, upgrades, and application requirements 12

Boot methods
USB, network (PXE, Preboot Execution Environment), solid-state or flash drive, internet-based (cloud recovery), external or hot-swappable drive, internal drive partition, multiboot (boot menu chooses the OS)
Clean install
Wipes the drive; new OS; restore files afterward
Upgrade (in-place)
Keeps files, apps, and settings; needs a supported path and compatible hardware and drivers
Image deployment
A prepared disk image copied to many machines (cloning, MDT, Configuration Manager)
Remote network installation
Boot from PXE, install from a server share
Zero-touch deployment
Device ships to the user and enrolls itself through the vendor's service (Windows Autopilot); no technician touches it
Recovery partition
Vendor partition that restores the factory image
Repair installation
Reinstalls Windows over itself, keeping data and apps, to fix system files
Third-party drivers
Load storage or RAID drivers during setup when the installer cannot see the disk
GPT
GUID partition table: UEFI, up to 128 partitions, disks over 2 TB
MBR
Master boot record: legacy BIOS, four primary partitions (or three plus an extended), 2 TB limit
Upgrade considerations
Back up files and user preferences; check application and driver support and backward compatibility; hardware compatibility; feature updates twice a year become once a year; product life cycle (EOL date)

Command-line tools 36

cd, dir
Change directory; list files (dir /a shows hidden)
md, rmdir
Make a directory; remove a directory (rmdir /s removes contents)
robocopy
Robust copy of folder trees with retries, mirroring (/mir), and permissions; xcopy is the old one
ipconfig
Address, mask, gateway; /all adds MAC and DNS; /release and /renew for DHCP; /flushdns clears the resolver cache
ping
Reachability and round trip; -t continuous; ping 127.0.0.1 tests the stack
tracert
Every hop to a destination
pathping
Tracert plus per-hop packet loss statistics over time
netstat
Open connections and listening ports; -a all, -n numeric, -b program names
nslookup
Query DNS for a name or address
net use
Map a drive: net use X: \\server\share; net use * /delete removes mappings
net user
List or manage local accounts; net user name password /add
chkdsk
Check the disk; /f fixes errors; /r locates bad sectors and recovers data
format
Format a volume with a filesystem; destroys data
diskpart
Command-line partitioning: list disk, select disk, clean, create partition, convert gpt
hostname, whoami, winver
Computer name; current user and groups; Windows version dialog
[command] /?
Help for any command
gpupdate
Apply Group Policy now; /force reapplies everything
gpresult
Show applied policies; /r summary
sfc
System File Checker; sfc /scannow repairs protected system files (DISM /online /cleanup-image /restorehealth repairs the source)
shutdown
shutdown /r /t 0 restarts now; /s shuts down
ls, pwd
List files (ls -la shows all with permissions); print the working directory
cd, mv, cp, rm
Change directory; move or rename; copy (cp -r for folders); remove (rm -rf removes a tree; no undo)
chmod, chown
Change permissions (r 4, w 2, x 1; owner group other, so 755 and 644); change owner and group
grep, find
Search text inside files; find files by name, size, or age
cat, man
Print a file; read the manual page for a command
top, ps
Live process view; list processes (ps aux)
df, du
Free space per filesystem; space used by a directory (du -sh)
fsck, mount
Check a filesystem (unmounted); attach a filesystem to a directory (umount detaches)
su, sudo
Switch user (to root with a password); run one command as root (sudo, logged, preferred)
apt, dnf
Package managers: apt on Debian and Ubuntu (apt update, apt install); dnf on Fedora and RHEL
ip, ping, curl, dig, traceroute
ip addr and ip route for addressing; ping; curl fetches URLs; dig queries DNS; traceroute lists hops
nano
Simple terminal text editor (vi and vim are the others)
/etc/passwd, /etc/shadow
User accounts; hashed passwords (root only)
/etc/hosts, /etc/fstab, /etc/resolv.conf
Static name mappings; filesystems to mount at boot; DNS servers
systemd, kernel, bootloader
Service manager (systemctl start, enable, status); the kernel is the core; GRUB is the bootloader
root
The all-powerful account (UID 0); log in as a normal user and use sudo

Control Panel, Settings, and Windows networking 25

Internet Options (Control Panel applet)
Browser security zones, proxy (Connections tab, LAN settings), certificates, home page for legacy Internet Explorer settings
Devices and Printers (Control Panel applet)
Add, remove, set default, printer properties and queues
Programs and Features (Control Panel applet)
Uninstall or change programs; turn Windows features on or off; view installed updates
Network and Sharing Center (Control Panel applet)
Adapter settings, network profile, sharing options, troubleshooting
System (Control Panel applet)
Computer name, domain or workgroup, remote settings, System Protection (restore points), advanced (performance, virtual memory, environment variables)
Windows Defender Firewall (Control Panel applet)
Turn on or off per profile; allow an app; advanced inbound and outbound rules by port
Mail (Control Panel applet)
Outlook profiles and data files
Sound (Control Panel applet)
Playback and recording devices, default device, levels
User Accounts (Control Panel applet)
Change account type, passwords, UAC level, credential manager
Device Manager (Control Panel applet)
The same devmgmt.msc
Indexing Options (Control Panel applet)
What Windows Search indexes and where
Administrative Tools (Control Panel applet)
Shortcuts to the MMC consoles
File Explorer Options (Control Panel applet)
General (open in This PC), View (show hidden files, show file extensions, protected OS files), Search
Power Options (Control Panel applet)
Power plans (Balanced, Power saver, High performance); sleep and hibernate timers; what closing the lid does; fast startup; USB selective suspend; standby; hibernate writes RAM to disk, sleep keeps RAM powered
System (Settings category)
Display, sound, notifications, power and sleep, storage, about
Devices (Settings category)
Bluetooth, printers, mouse, typing, pen, AutoPlay, USB
Network and Internet (Settings category)
Status, Wi-Fi, Ethernet, VPN, proxy, data usage, metered connections
Personalization (Settings category)
Background, colors, lock screen, themes, start, taskbar
Apps (Settings category)
Apps and features (uninstall), default apps, optional features, startup
Accounts (Settings category)
Your info, email accounts, sign-in options (PIN, Windows Hello), access work or school, family
Time and Language (Settings category)
Date and time, region, language, speech
Gaming (Settings category)
Game bar, captures, game mode
Ease of Access (Settings category)
Accessibility: narrator, magnifier, high contrast, captions
Privacy (Settings category)
Location, camera, microphone, diagnostics, app permissions
Update and Security (Settings category)
Windows Update, delivery optimization, Windows Security, backup, troubleshoot, recovery, activation, Find My Device

macOS and Linux features 7

File types
.dmg is a disk image you mount and drag the app from; .pkg is an installer package; .app is the application bundle itself; App Store installs and updates; uninstall by dragging to Trash or running the vendor uninstaller
System folders
/Applications (apps), /Users (home folders), /Library (system-wide support files), /System (the OS, protected), /Users/name/Library (per-user settings, hidden)
Apple ID and corporate restrictions
Personal Apple ID for iCloud and the App Store; managed Apple IDs and MDM restrict what corporate Macs can do
Best practices
Backups with Time Machine, antivirus, updates and patches, Rapid Security Response (small security patches between full updates)
System Preferences / Settings
Displays, Network, Printers and Scanners, Privacy and Security, Accessibility, Time Machine
Features
Multiple desktops (Spaces) and Mission Control, Keychain (passwords), Spotlight (search), iCloud, iMessage, FaceTime, iCloud Drive, trackpad gestures, Finder (file manager), Dock, Continuity and Handoff between Apple devices
Utilities
Disk Utility (partition, format, First Aid), FileVault (full-disk encryption), Terminal (shell), Force Quit (Command-Option-Esc)

Security concepts 45

Principle of least privilege
Every account gets only the rights its job needs
Zero Trust
Never trust by location; verify every user and device for every request
Access control list
The list of who may do what to a resource (files, firewalls, routers)
MFA methods
Email code, hardware token, authenticator application, SMS, voice call, TOTP (time-based one-time password), OTP; SMS and voice are the weakest
SAML
Security Assertion Markup Language: passes authentication between an identity provider and a web application; the basis of web SSO
SSO
One login for many systems
Just-in-time access
Elevated rights granted only for the task and the time needed
PAM
Privileged access management: vaulted admin credentials, checked out, logged
MDM
Mobile device management: enroll, configure, enforce, wipe
DLP
Data loss prevention: stops sensitive data leaving by email, upload, or USB
IAM
Identity and access management: the whole system of accounts, roles, and authentication
Directory services
Active Directory and LDAP: the database of users, computers, and groups
WPA2
AES-CCMP encryption; personal (pre-shared key) or enterprise (802.1X with RADIUS); the minimum acceptable today
WPA3
Stronger: SAE handshake resists offline password guessing, forward secrecy, protected management frames; enterprise 192-bit mode
TKIP
The old WPA encryption; deprecated, weak; never choose it
AES
Advanced Encryption Standard: the strong cipher in WPA2 and WPA3
RADIUS
Central authentication for Wi-Fi and VPN; UDP 1812 and 1813; encrypts only the password
TACACS+
Cisco device administration authentication; TCP 49; encrypts the whole session; separates authentication, authorization, accounting
Kerberos
Active Directory's ticket-based authentication; the KDC issues tickets; clocks must agree within about five minutes
Multifactor
Something you know, have, or are; two of them
Trojan
Pretends to be useful software; installs a backdoor
Rootkit
Hides deep in the OS or firmware; invisible to normal tools; often needs a reinstall
Virus
Attaches to files; spreads when they run
Spyware
Watches and reports activity
Ransomware
Encrypts files and demands payment
Keylogger
Records keystrokes for passwords
Boot sector virus
Infects the boot record; loads before the OS
Cryptominer
Steals CPU and GPU to mine currency; slow and hot machine
Stalkerware
Secretly tracks a person's location and messages
Fileless
Lives in memory and legitimate tools (PowerShell); no file for antivirus to scan
Adware and PUP
Ads and unwanted bundled programs; nuisance more than threat
Tools
Recovery console (WinRE), EDR, MDR (managed by a provider), XDR (across endpoints and network), antivirus, antimalware, email security gateway, software firewalls, user education and antiphishing training, OS reinstallation as the last resort
Phishing, vishing, smishing
Fake email, voice call, SMS; QR code phishing hides the link in a code
Spear phishing and whaling
Targeted at a person; targeted at an executive
Shoulder surfing, tailgating
Watching a screen or keyboard; following someone through a door
Impersonation, dumpster diving
Pretending to be someone; digging paper out of the trash
DoS and DDoS
Flooding a service; distributed from many bots
Evil twin
A rogue access point with the real network's name
Zero-day
Exploits a flaw with no patch yet
Spoofing, on-path
Faking an address or identity; intercepting between two parties
Brute force, dictionary
Trying every password; trying likely words
Insider threat
An authorized person misusing access
SQL injection, XSS
Database commands through a form; scripts injected into a web page
BEC, supply chain
Business email compromise (fake invoice from the boss); attack through a vendor or software pipeline
Vulnerabilities
Non-compliant, unpatched, unprotected (no antivirus or firewall), EOL systems, BYOD devices

Windows security, Active Directory, hardening, and mobile security 9

Defender Antivirus
Built in; turn on, keep definitions updated; real-time protection
Firewall
On per profile; port rules and application rules; block inbound by default
Accounts
Local versus Microsoft account; Standard user; Administrator; Guest (disabled); Power Users (legacy group)
Sign-in options
Username and password, PIN, fingerprint, facial recognition, SSO, passwordless Windows Hello
NTFS versus share permissions
Share permissions apply only over the network; NTFS applies locally and remotely; the effective permission is the most restrictive of the two; an explicit deny wins
NTFS rules
Copying to another volume takes the destination's permissions; moving within a volume keeps the original; inheritance flows from the parent unless blocked; attributes: read-only, hidden, system, archive
UAC
User Account Control prompts before elevation; run as administrator only when needed; standard users enter admin credentials
BitLocker and To Go
Full-volume encryption keyed to the TPM (Pro and above); BitLocker To Go for removable drives; save the recovery key
EFS
Encrypting File System: per-file or per-folder encryption tied to the user's certificate; lose the key, lose the files

SOHO, browser, disposal, and the malware removal procedure 7

Drilling, shredding, incineration
Physical destruction; certain; nothing recoverable
Degaussing
A strong magnet erases magnetic drives and tape; useless on SSDs
Erasing and wiping
Overwriting or secure erase; keeps the drive usable for reuse
Low-level format
Factory-level reset of the drive surface; modern drives do it in firmware
Standard format
Rebuilds the filesystem; a quick format leaves data recoverable
Outsourcing
Third-party vendor with a certificate of destruction or recycling
Regulations
E-waste rules and data laws decide what must be destroyed and how

Software troubleshooting 23

Blue screen of death
Driver, hardware, or memory fault; note the stop code; recent changes; safe mode; roll back the driver; memory test
Degraded performance
Too many startup items, low RAM, full or failing disk, malware, background updates; Task Manager and Resource Monitor
Boot issues
Corrupted boot files or wrong boot order; Startup Repair in WinRE; bootrec; check the drive
Frequent shutdowns
Overheating, failing power supply, driver; check temperatures and Event Viewer
Services not starting
Dependency or account problem; Services console, Event Viewer, sfc
Applications crashing
Update or reinstall the app; check Event Viewer; compatibility mode; sfc
Low memory warnings
Not enough RAM or paging file; close apps; add RAM; check for leaks
USB controller resource warnings
Too many devices on one controller; move devices to another port or a powered hub
System instability
Bad drivers, failing hardware, corrupt system files; sfc, DISM, memory test, roll back updates
No OS found
Boot order, unplugged drive, corrupted boot sector, USB stick left in; firmware settings; Startup Repair
Slow profile load
Large profile, roaming profile, login scripts, mapped drives timing out, corrupt profile (rebuild it)
Time drift
CMOS battery or a time source failure; sync with the domain or NTP; certificates and Kerberos fail when time is off
App fails to launch, close, or crashes
Force stop, clear cache, update, reinstall, restart the device
App fails to update or install
Storage full, OS version too old, no network, store account problem, MDM restriction
Slow to respond
Storage full, too many background apps, old OS, overheating, malware; restart
OS fails to update
Storage, battery level, network, unsupported (EOL) device
Battery life issues
Screen brightness, background apps, radios, poor signal, aged battery, malware
Random reboots
Bad app, OS bug, overheating, failing battery; update, remove recent apps, factory reset last
Connectivity issues
Bluetooth: pair again; Wi-Fi: forget and rejoin, airplane mode; NFC: enable it, remove the case
Screen does not autorotate
Rotation lock is on; then the sensor or a calibration
Mobile: unofficial app stores, developer mode, root or jailbreak
Bypass the platform's protections; malware and unsupported by MDM
Mobile: unauthorized or malicious app, application spoofing
A fake copy of a real app; remove it, change passwords
Browser: random pop-ups, certificate warnings, redirection, degraded performance
Adware, a hijacked browser, a bad extension, or an on-path attack; reset the browser, remove extensions, check DNS and hosts file

Documentation, change management, and backups 7

Full
Everything; slowest to make, fastest to restore
Incremental
Only what changed since the last backup of any kind; small and fast; restore needs the full plus every incremental in order
Differential
Everything changed since the last full; grows daily; restore needs the full plus the latest differential
Synthetic full
A full backup assembled on the backup server from the last full and later incrementals, without touching the client
Recovery
In-place or overwrite restores over the original; alternative location restores to a new folder or machine to compare
Testing
Restore regularly; a backup never tested is not a backup; set a frequency
Rotation
On-site (fast) versus off-site (disaster); grandfather-father-son: daily, weekly, monthly sets; 3-2-1 rule: three copies, two media types, one off-site

Scripting, remote access, and AI 17

.bat
Windows batch, cmd.exe; oldest and simplest
.ps1
PowerShell; object-based, the Windows administrator's tool; execution policy may block scripts
.vbs
VBScript; legacy Windows scripting (deprecated)
.sh
Shell (bash) on Linux and macOS
.js
JavaScript; browsers and Node
.py
Python; cross-platform automation
Use cases
Basic automation, restarting machines, remapping network drives, installing applications, automated backups, gathering information, initiating updates
Considerations
Scripts can unintentionally introduce malware, inadvertently change system settings, or crash a browser or system by mishandling resources; test in a sandbox, read before running
RDP
Remote Desktop Protocol, TCP 3389; full Windows desktop; host needs Pro or above; use with a VPN or gateway, never open to the internet
VPN
Encrypted tunnel to the office network; then use any tool inside
VNC
Cross-platform screen sharing, port 5900; weak security unless tunneled
SSH
Secure shell, TCP 22; encrypted command line for Linux, macOS, network gear
RMM
Remote monitoring and management agents used by service providers; patching, alerts, remote control
SPICE
Simple Protocol for Independent Computing Environments: remote display for virtual machines (KVM and QEMU)
WinRM
Windows Remote Management: PowerShell remoting over HTTP 5985 and HTTPS 5986
Third-party tools
Screen-sharing, videoconferencing, file transfer, desktop management software; check their security and who can connect
Security
Encryption, MFA, least privilege, logging, closing ports when done, verifying the person on the other end

Questions people ask

How many CompTIA A+ Core 2 220-1202 flashcards are there?

405: 194 Acronyms, 7 The exam itself, 16 Operating systems, filesystems, and Windows editions, 12 Installation, upgrades, and application requirements, 36 Command-line tools, 25 Control Panel, Settings, and Windows networking, 7 macOS and Linux features, 45 Security concepts, 9 Windows security, Active Directory, hardening, and mobile security, 7 SOHO, browser, disposal, and the malware removal procedure, 23 Software troubleshooting, 7 Documentation, change management, and backups, 17 Scripting, remote access, and AI. They come from the course's cheat sheet and glossary, so what you drill is what the lessons teach.

Do I need an account?

No. The cards you mark as known are remembered in this browser only. Sign in to the course for progress that follows you between devices.